Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis

被引:372
|
作者
Friedrich-Rust, M. [1 ]
Nierhoff, J. [2 ]
Lupsor, M. [3 ]
Sporea, I. [4 ]
Fierbinteanu-Braticevici, C. [5 ]
Strobel, D. [6 ]
Takahashi, H. [7 ]
Yoneda, M. [8 ]
Suda, T. [9 ]
Zeuzem, S. [1 ]
Herrmann, E. [2 ]
机构
[1] Goethe Univ Frankfurt, Dept Internal Med 1, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Inst Biostat & Math Modeling, Fac Med, D-60590 Frankfurt, Germany
[3] Univ Med & Pharm, Dept Ultrasonog, Cluj Napoca, Romania
[4] Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisoara, Romania
[5] Univ Hosp, Med Clin 2, Bucharest, Romania
[6] Univ Erlangen Nurnberg, Dept Internal Med 1, Erlangen, Germany
[7] Saga Med Sch, Dept Internal Med, Saga, Japan
[8] Yokohama City Univ Med, Div Gastroenterol, Yokohama, Kanagawa, Japan
[9] Niigata Univ, Dept Gastroenterol & Hepatol, Niigata, Japan
关键词
ARFI; elastography; fibrosis staging; liver biopsy; liver stiffness; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; SAMPLING VARIABILITY; ARFI TECHNOLOGY; IN-VIVO; FIBROTEST; DISEASE; BIOPSY; ELASTICITY; DIAGNOSIS;
D O I
10.1111/j.1365-2893.2011.01537.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Acoustic Radiation Force Impulse (ARFI) imaging is a novel ultrasound-based elastography method that is integrated in a conventional ultrasound machine enabling the exact localization of measurement site. It might present an alternative method to transient elastography for the noninvasive assessment of liver fibrosis. At present, studies with small patient population have shown promising results. A systematic review and meta-analysis of pooled patient data were performed to evaluate the overall performance of ARFI for the staging of liver fibrosis. Literature databases were searched up to 10/2010. The authors of the original publication were contacted, and the original patient data were requested. A meta-analysis was performed using a random effect meta-analytic method for diagnostic tests. In addition, available data comparing ARFI with FibroScan with the DeLong test were evaluated. Literature search yielded nine full-paper publications evaluating ARFI while using liver biopsy as reference method. Original patient data were available from eight studies including 518 patients. The mean diagnostic accuracy of ARFI expressed as areas under ROC curves (AUROC) was 0.87 for the diagnosis of significant fibrosis (F = 2), 0.91 for the diagnosis of severe fibrosis (F = 3), and 0.93 for the diagnosis of cirrhosis. ARFI can be performed with good diagnostic accuracy for the noninvasive staging of liver fibrosis.
引用
收藏
页码:E212 / E219
页数:8
相关论文
共 50 条
  • [41] The Performance of Enhanced Liver Fibrosis (ELF) Test for the Staging of Liver Fibrosis: A Meta-Analysis
    Xie, Qingsong
    Zhou, Xiaohu
    Huang, Pengfei
    Wei, Jianfeng
    Wang, Weilin
    Zheng, Shusen
    PLOS ONE, 2014, 9 (04):
  • [42] Acoustic Radiation Force Impulse (ARFI) for Fibrosis Staging in Patients with Autoimmune Hepatitis
    Efe, Cumali
    Gungoren, Merve Sibel
    Ozaslan, Ersan
    Akbiyik, Filiz
    Kav, Taylan
    HEPATO-GASTROENTEROLOGY, 2015, 62 (139) : 670 - 672
  • [43] Acoustic radiation force impulse imaging (ARFI) in the assessment of liver fibrosis: an analysis of performance within a 'real-life' Australian setting
    Nadebaum, D.
    Gibson, R.
    Howell, J.
    Halliday, J.
    Christie, M.
    Gorelik, A.
    Liew, D.
    Nicoll, A.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 : 75 - 75
  • [44] Acoustic Radiation Force Impulse Imaging for Assessing Liver Fibrosis Preoperatively in Infants With Biliary Atresia
    Gao, Fen
    Chen, Ya-Qing
    Fang, Jing
    Gu, Sheng-Li
    Li, Luan
    Wang, Xiao-Ying
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (08) : 1571 - 1578
  • [45] The diagnostic accuracy of liver fibrosis in non-viral liver diseases using acoustic radiation force impulse elastography: A systematic review and meta-analysis
    Lin, Yuanqiang
    Li, Hequn
    Jin, Chunxiang
    Wang, Hui
    Jiang, Bo
    PLOS ONE, 2020, 15 (01):
  • [46] PERFORMANCE OF ACOUSTIC RADIATION FORCE IMPULSE IMAGING IN THE NONINVASIVE ASSESSMENT OF LIVER FIBROSIS, IN COMPARISON TO FIB4 SCORE
    Lupsor, M.
    Badea, R.
    Stefanescu, H.
    Feier, D.
    Crisan, D.
    Radu, C.
    Serban, A.
    Sparchez, Z.
    Maniu, A.
    JOURNAL OF HEPATOLOGY, 2011, 54 : S136 - S136
  • [47] Noninvasive Assessment of Liver Fibrosis with Acoustic Radiation Force Impulse Imaging: Increased Liver and Splenic Stiffness in Patients with Liver Fibrosis and Cirrhosis
    Grgurevic, I.
    Cikara, I.
    Horvat, J.
    Lukic, I. K.
    Heinzl, R.
    Banic, M.
    Kujundzic, M.
    Brkljacic, B.
    ULTRASCHALL IN DER MEDIZIN, 2011, 32 (02): : 160 - 166
  • [48] Comparison of Liver Stiffness Assessment by FibroScan® and Acoustic Radiation Force Impulse Imaging® for the Evaluation of Liver Fibrosis and Cirrhosis
    Salzl, Petra
    Reiberger, Thomas
    Homoncik, Monika
    Payer, Berit A.
    Schwengerer, Bernadette
    Peck-Radosavljevic, Markus
    Ferlitsch, Arnulf
    GASTROENTEROLOGY, 2010, 138 (05) : S778 - S778
  • [49] Comparison of Liver Stiffness Assessment by Fibroscan® and Acoustic Radiation Force Impulse Imaging® for the evaluation of liver fibrosis and cirrhosis
    Ferlitsch, Arnulf
    Salzl, Petra
    Reiberger, Thomas
    Homoncik, Monika
    Payer, Berit
    Schwengerer, Bernadette
    Peck-Radosavljevic, Markus
    WIENER KLINISCHE WOCHENSCHRIFT, 2010, 122 (17-18) : A11 - A11
  • [50] COMPARISON OF LIVER STIFFNESS ASSESSMENT BY FIBROSCAN® AND ACOUSTIC RADIATION FORCE IMPULSE IMAGING® FOR THE EVALUATION OF LIVER FIBROSIS AND CIRRHOSIS
    Salzl, P.
    Reiberger, T.
    Homoncik, M.
    Payer, B.
    Schwengerer, B.
    Peck-Radosavljevic, M.
    Ferlitsch, A.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S171 - S172