Noninvasive measurement of blood hemoglobin concentration by time-resolved transmission spectroscopy

被引:2
|
作者
Sun, M. X. [1 ,2 ]
Zhang, L. Y. [3 ]
Jiang, C. Y. [1 ,2 ]
Yuan, Y. [1 ,2 ]
Yang, J. C. [1 ,2 ]
Tian, L. [1 ,2 ]
Wu, J. P. [1 ,2 ]
Li, Y. X. [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Inst Biomed Engn, Laser Med Lab, Tianjin 300192, Peoples R China
[2] Peking Union Med Coll, Tianjin 300192, Peoples R China
[3] Mil Transportat Coll, Basic Dept, Tianjin 300161, Peoples R China
来源
OPTIK | 2015年 / 126卷 / 04期
关键词
Blood hemoglobin concentration; Time-resolved transmission spectroscopy; Noninvasive measurement; Laplace transform; LIGHT-SCATTERING; REFLECTANCE;
D O I
10.1016/j.ijleo.2014.07.148
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An optical spectroscopic method is investigated theoretically for noninvasive and continuous monitoring of blood hemoglobin levels. The method may provide accurate measurement of hemoglobin concentration by detection and analysis of dynamic dual wavelength time-resolved transmission under a condition of artificial blood flow kinetics in a human finger. This condition can assist light scattering and leads to a better signal-to-noise ratio necessary to accurate measurement of transmission. The modified parametric slopes were derived from the Laplace transformed data of the time-resolved transmittance. Continuous hemoglobin concentration was measured in the range from 6 to 16 g/dl and the results show that the sensitivity of hemoglobin sensing is enhanced when we use selected values of the Laplace transform parameter p=5 x 10(10) s(-1) comparing with the continuous wave situation. (C) 2014 Elsevier GmbH. All rights reserved.
引用
收藏
页码:460 / 463
页数:4
相关论文
共 50 条
  • [21] Time-Resolved Dynamic Spectroscopy Measurement for Laser Induced Breakdown Spectroscopy
    Zhang Zhen-Rong
    Fang Bo-Lang
    Li Guo-Hua
    Ye Jing-Feng
    Wang Sheng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (04) : 952 - 955
  • [22] Application of time-resolved spectroscopy to concentration measurements in gas mixtures
    Lavorel, B
    Hertz, E
    Faucher, O
    Chaux, R
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE, 2001, 2 (07): : 1029 - 1036
  • [23] Intraoperative monitoring of depth-dependent hemoglobin concentration changes during carotid endarterectomy by time-resolved spectroscopy
    Sato, Chie
    Yamaguchi, Takekane
    Seida, Mitsuru
    Ota, Yoshihisa
    Yu, Mae
    Iguchi, Yoshinobu
    Nemoto, Masahito
    Hoshi, Yoko
    APPLIED OPTICS, 2007, 46 (14) : 2785 - 2792
  • [24] Time-resolved photoacoustics for glucose concentration measurement: theory and experiment
    Shen, YC
    MacKenzie, HA
    Lindberg, J
    Lu, ZH
    1999 INTERNATIONAL CONFERENCE ON BIOMEDICAL OPTICS (BMO'99), 1999, 3863 : 167 - 171
  • [25] Error in noninvasive spectrophotometric measurement of blood hemoglobin concentration under conditions of blood loss
    Naftalovich, Rotem
    Naftalovich, Daniel
    MEDICAL HYPOTHESES, 2011, 77 (04) : 665 - 667
  • [26] Measurement of transcutaneous hemoglobin concentration by noninvasive white-light spectroscopy in infants
    Rabe, H
    Stupp, N
    Özgün, M
    Harms, E
    Jungmann, H
    PEDIATRICS, 2005, 116 (04) : 841 - 843
  • [27] Time-resolved fluorescence of hemoglobin species
    Gryczynski, Z
    Beretta, S
    Lubkowski, J
    Razynska, A
    Gryczynski, I
    Bucci, E
    BIOPHYSICAL CHEMISTRY, 1997, 64 (1-3) : 81 - 91
  • [28] MEASUREMENT OF CLUSTER REORGANIZATION BY TIME-RESOLVED PHOTOELECTRON-SPECTROSCOPY
    SYAGE, JA
    CHEMICAL PHYSICS LETTERS, 1993, 202 (3-4) : 227 - 232
  • [29] Spatially resolved blood oxygenation measurements using time-resolved photoacoustic spectroscopy
    Laufer, J. G.
    Elwell, C. E.
    Delpy, D. T.
    Beard, P. C.
    OXYGEN TRANSPORT TO TISSUE XXVII, 2006, 578 : 155 - 160
  • [30] NONINVASIVE HEMOGLOBIN MEASUREMENT FOR BLOOD DONATION
    Inaba, S. I.
    Okubo, R.
    Rikitake, T.
    Kawano, T.
    Sugimoto, S.
    Ozawa, T.
    VOX SANGUINIS, 2011, 101 : 27 - 27