Implementation of MPC for an all-air system in an educational building

被引:0
|
作者
Merema, Bart [1 ]
Carton, Quinten [1 ]
Saelens, Dirk [2 ,3 ]
Breesch, Hilde [1 ]
机构
[1] Katholieke Univ Leuven, Dept Civil Engn Bldg Phys & Sustainable Design, Ghent Technol Campus, Leuven, Belgium
[2] Katholieke Univ Leuven, Dept Civil Engn, Bldg Phys, Leuven, Belgium
[3] Energyville, Genk, Belgium
来源
关键词
MODEL-PREDICTIVE CONTROL;
D O I
10.1051/e3sconf/202124611007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The building sector has to significantly reduce the total energy use. A predictive control could be a solution to control an HVAC system more energy efficiently since it takes into account the current measurements and the future demand In this study a predictive control framework is implemented in an educational building with two lecture rooms. The airflow rate is controlled by VAV boxes based on measurements of CO2 concentration and operative temperature. The dynamic model used for optimization of the control input is a grey-box model, previously identified using measurement data. Weather forecasts and weekly lecture schedules are used as forecasts for the optimization of future control actions. The control actions resulting from the optimization are written to the set points for supply air temperature and VAV damper position using the BACnet interface. Results of the first trial indicate that the predictive control is able to control the room temperature and CO2 concentration, even with uncertainty introduced by the forecasts. Prediction errors observed were 0.17 degrees C for room temperature and 87 ppm for indoor CO2 concentration.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] PERFORMANCE OF AIR CONDITIONING SYSTEM IN EDUCATIONAL BUILDING FOR ENERGY CONSERVATION
    Limphitakphong, Nantamol
    Chaikatetham, Nuttasate
    Khaimook, Therdthai
    Chavalparit, Orathai
    INTERNATIONAL JOURNAL OF GEOMATE, 2019, 16 (56): : 177 - 182
  • [22] Using geothermal energy in enhancing all-air HVAC system performance - Case study, thermal analysis and economic insights
    Darwiche, Mohamad
    Faraj, Jalal
    Ali, Samer
    Murr, Rabih
    Taher, Rani
    El Hage, Hicham
    Khaled, Mahmoud
    UNCONVENTIONAL RESOURCES, 2025, 5
  • [23] Required Energy for Outside Air Treatment in a Central Plant with Constant All-Air Volume Operation.
    Clain, Francois
    Promoclim E: Etudes Thermiques et Aerauliques, 1976, 7 E (03): : 217 - 222
  • [24] Cooling energy consumption and operating costs: evaporative all-air and air-and-water systems in the Italian climate
    Bellia, L
    Mazzei, P
    Minichiello, F
    Palombo, A
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2000, 24 (02) : 163 - 175
  • [25] All-air vs. radiant cooling systems: Analysis of design and operation factors that impact building cooling loads (ASHRAE RP 1729)
    Moftakhari, Ardeshir
    Bourne, Stephen
    Novoselac, Atila
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (04) : 381 - 401
  • [26] Economic comparison of TABS, PCM ceiling panels and all-air systems for cooling offices
    Boccardo, Luca Bergia
    Kazanci, Ongun Berk
    Allerhand, Jose Quesada
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2019, 205
  • [27] A Dynamic Simulation of Indoor Polydispersion of Particles in All-Air Air-Conditioned Environment with Dynamical Particle Sources
    Li, Min
    Wu, Chun-Liang
    Sun, Liang-Liang
    Lai, Alvin C. K.
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (02) : 282 - 291
  • [28] Educational System Building
    Cohen, David K.
    Spillane, James P.
    EDUCATIONAL POLICY, 2019, 33 (06) : 807 - 811
  • [29] Single and multi-family residential central all-air HVAC system operational characteristics in cooling-dominated climate
    Cetin, Kristen Sara
    Novoselac, Atila
    ENERGY AND BUILDINGS, 2015, 96 : 210 - 220
  • [30] Study on the Implementation of a Solar Photovoltaic System with Self-Consumption in an Educational Building
    dos Santos Castilho, Carolina
    N. Torres, Joao Paulo
    Ferreira Fernandes, Carlos A.
    Marques Lameirinhas, Ricardo A.
    ENERGIES, 2021, 14 (08)