Different Neoatherosclerosis Patterns in Drug-Eluting- and Bare-Metal Stent Restenosis - Optical Coherence Tomography Study -

被引:25
|
作者
Nakamura, Daisuke [1 ]
Yasumura, Keisuke [1 ]
Nakamura, Hitoshi [1 ]
Matsuhiro, Yutaka [1 ]
Yasumoto, Koji [1 ]
Tanaka, Akihiro [1 ]
Matsunaga-Lee, Yasuharu [1 ]
Yano, Masamichi [1 ]
Yamato, Masaki [1 ]
Egami, Yasuyuki [1 ]
Shutta, Ryu [1 ]
Sakata, Yasushi [2 ]
Tanouchi, Jun [1 ]
Nishino, Masami [1 ]
机构
[1] Osaka Rosai Hosp, Div Cardiol, 1179-3 Nagasone Cho, Sakai, Osaka 5918025, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Suita, Osaka, Japan
关键词
In-stent restenosis; Neoatherosclerosis; Optical coherence tomography; CORONARY-ARTERY; PLAQUE; MECHANISMS; THROMBOSIS; INTERVENTION; IMPACT;
D O I
10.1253/circj.CJ-18-0701
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There are few reports about the differences between drug-eluting stents (DES) and bare metal stents (BMS) in neoatherosclerosis associated with in-stent restenosis (ISR), so we compared the frequency and characteristics of neoatherosclerosis with ISR evaluated by optical coherence tomography (OCT) in the present study. Methods and Results: Between March 2009 and November 2016, 98 consecutive patients with ISR who underwent diagnostic OCT were enrolled: 34 patients had a BMS, 34 had a 1st-generation DES, and 30 had a 2nd-generation DES. Neoatherosclerosis was defined as a lipid neointima (including a thin-cap fibroatheroma [TCFA] neointima, defined as a fibroatheroma with a fibrous cap <65 mu m) or calcified neointima. As a result, lipid neointima, TCFA neointima and calcified neointima were detected in 39.8%, 14.3%, and 5.1%, respectively, of all patients. The frequency of neoatherosclerosis was significantly greater with DES than BMS (48.4% vs. 23.5%, P=0.018). The minimum fibrous cap thickness was significantly thicker with DES than BMS (110.3 +/- 41.1 mu m vs. 62.5 +/- 17.1 mu m, P<0.001). In addition, longitudinal extension of neoatherosclerosis in the stented segment was less with DES than BMS (20.2 +/- 15.1% vs. 71.8 +/- 27.1%, respectively, P=0.001). Conclusions: OCT imaging demonstrated that neoatherosclerosis with ISR was more frequent with DES than BMS and its pattern exhibited a more focal and thick fibrous cap as compared with BMS.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [21] Difference of Neoatherosclerosis Pattern in Lesions With In-Stent Restenosis Among Bare-Metal, First and Second Generation Drug-Eluting Stents
    Nakamura, Daisuke
    Nishino, Masami
    Yasumura, Keisuke
    Yasumoto, Koji
    Tanaka, Akihiro
    Mori, Naoki
    Yano, Masamichi
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    CIRCULATION, 2017, 136
  • [22] Clinical Outcomes of Drug-Eluting Versus Bare-Metal In-Stent Restenosis
    Singh, Inder M.
    Filby, Steven J.
    El Sakr, Fredy
    Gorodeski, Eiran Z.
    Lincoff, A. Michael
    Ellis, Stephen G.
    Shishehbor, Mehdi H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (03) : 338 - 342
  • [23] Clinical Outcomes of Drug-Eluting versus Bare-Metal In-Stent Restenosis
    Singh, Inder M.
    Filby, Steven J.
    El Sakr, Fredy
    Gorodeski, Eiran Z.
    Lincoff, A. Michael
    Ellis, Stephen G.
    Shishehbor, Mehdi H.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 204D - 204D
  • [24] Neoatherosclerosis 16years following bare-metal stent implantation: Different tissue components in different underlying lesions observed with optical coherence tomography
    Hashikata, Takehiro
    Tojo, Taiki
    Ishii, Sayaka
    Kitasato, Lisa
    Kameda, Ryo
    Shimohama, Takao
    Yamaoka-Tojo, Minako
    Ako, Junya
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 170 (01) : E8 - E10
  • [25] The effects of drug-eluting stent polymer on measurement of strut thickness by optical coherence tomography: In-vitro comparison with bare-metal stent
    Mizuno, Masayuki
    Takano, Masamichi
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (01) : 48 - 49
  • [26] Difference in Optical Coherence Tomography Findings of Very Late In-Stent Restenosis Lesions Between After Bare-Metal Stent and Sirolimus-Eluting Stent Implantation
    Tada, Takeshi
    Kadota, Kazushige
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION, 2014, 130
  • [27] Various vascular responses in restenosis lesions of drug-eluting stents: comparison of optical coherence tomography findings with bare-metal stents
    Yamamoto, M.
    Takano, M.
    Kimata, N.
    Inami, T.
    Murakami, D.
    Okamatsu, K.
    Ohba, T.
    Ibuki, C.
    Seino, Y.
    Mizuno, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 367 - 367
  • [28] Effectiveness of everolimus-eluting stents in the treatment of drug-eluting stent versus bare-metal stent restenosis
    Almalla, Mohammad
    Pross, Verena
    Marx, Nikolaus
    Hoffmann, Rainer
    CORONARY ARTERY DISEASE, 2012, 23 (07) : 492 - 496
  • [29] The morphological findings of very late in-stent restenosis after bare-metal stent implantation: optical coherence tomography analysis
    Habara, M.
    Terashima, M.
    Nasu, K.
    Kinoshita, Y.
    Tsuchikane, E. Etsuo
    Asakura, Y.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2011, 32 : 402 - 402
  • [30] The morphological findings of very late in-stent restenosis after bare-metal stent implantation: Optical Coherence Tomography analysis
    Habara, M.
    Terashima, M.
    Nasu, K.
    Ko, Y.
    Ito, T.
    Kinoshita, Y.
    Tsuchikane, E.
    Asakura, Y.
    Katoh, O.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2010, 31 : 356 - 357