Monte Carlo simulations studies in small animal PET

被引:0
|
作者
Branco, S. [1 ]
Almeida, P. [1 ]
Jan, S.
机构
[1] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, Lisbon, Portugal
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This work is based on the use of an implemented PET simulation system dedicated for small animal PET imaging using. GATE, a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET((R)) FOCUS system and to implement realistic phantoms, as the MOBY phantom and imaging maps of real exams. The use of the microPET((R)) FOCUS model with GATE was validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results of realistic simulations for static and dynamic studies are presented. These simulations include realistic injected doses in the animal and realistic time framing.
引用
收藏
页码:111 / 115
页数:5
相关论文
共 50 条
  • [31] Characterization of dual layer phoswich detector performance for small animal PET using Monte Carlo simulation
    Chung, YH
    Choi, Y
    Cho, G
    Choe, YS
    Lee, KH
    Kim, BT
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2881 - 2890
  • [32] Comparison of different approaches based on Monte Carlo methods to calculate the system matrix for small animal PET
    Nerina Gimenez, Eva
    Nacher, E.
    Gimenez, M.
    Benlloch, J. M.
    Rafecas, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 346 - 349
  • [33] Comparison of different Monte-Carlo based approaches to calculating the system matrix for small animal PET
    Gimenez, E. N.
    Mora, C.
    Gimenez, M.
    Benlloch, J. M.
    Rafecas, M.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2085 - 2088
  • [34] A GATE Monte Carlo model for a newly developed small animal PET scanner: the IRI-microPET
    Rad, S. Z. Islami
    Peyvandi, R. Gholipour
    Sadeghi, M. K.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (02): : 93 - 100
  • [35] A Monte Carlo study of qualitative and quantitative accuracy of 89Zr small animal PET images
    D'Ambrosio, D.
    Zagni, F.
    Pancaldi, D.
    Fanti, S.
    Marengo, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S339 - S339
  • [36] Towards Quantitative Image Reconstruction Using Monte-Carlo Simulations in Multi-Wire Proportional Chamber-Based Small Animal PET
    Gottschlag, Holger
    Koesters, Thomas
    Vernekohl, Don
    Reygers, Klaus
    Schaefers, Klaus P.
    Wuebbeling, Frank
    Wessels, Johannes P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3343 - 3354
  • [37] Monte Carlo Simulation of Small Electron Fields for Small Animal Irradiation
    Lee, C.
    Chen, A.
    Chao, T.
    Tung, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] Monte Carlo simulations and dosimetric studies of an irradiation facility
    Belchior, A.
    Botelho, M. L.
    Vaz, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 70 - 72
  • [39] Validation of GATE Monte Carlo simulations for Siemens PET/CT and PET/MR systems
    Kertesz, H.
    Renner, A.
    Rausch, I.
    Beyer, T.
    Cal-Gonzalez, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S298 - S299
  • [40] Quantum Monte Carlo studies on small molecules
    Galek, Peter T. A.
    Handy, Nicholas C.
    Lester, William A., Jr.
    MOLECULAR PHYSICS, 2006, 104 (19) : 3069 - 3085