Measurement of Rat Magnetocardiograms by Using a High-TC SQUID Magnetometer System

被引:3
|
作者
Kim, In-Seon [1 ]
Kwon, Hyuckchan [1 ]
Ahn, San [2 ]
Song, Jong-Hyun [2 ]
机构
[1] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
[2] Chungnam Natl Univ, Taejon 305764, South Korea
关键词
Biomagnetic measurement; high-T-C SQUID; magnetocardiography; rat; REPOLARIZATION;
D O I
10.1109/TASC.2010.2094994
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have measured biomagnetic signals in rat by using a high-T-C SQUID magnetometer system employing a small magnetically shielded box. For the rat cardiac magnetic field measurements, a healthy rat with body weight of about 350 g was anesthetized and fixed on a plastic xyz-stage in supine position inside the magnetically shielded box. We could obtain strong R-peak amplitude up to 56 pT with well defined P-, QRS-, T-wave, and ST-segment separating T-wave from QRS complex. We measured and analysed rat MCG waveforms for 5 x 5 grid measurements covering 60 mm x 60 mm area and 12 circular measurements centered at the heart position. This work demonstrates that the potential advantages of high-T-C SQUID magnetometer system in evaluating the rat MCG measurement for animal models of cardiac electrical activities.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 50 条
  • [41] Flip-Chip High-Tc DC SQUID Magnetometer With a Ferromagnetic Flux Antenna
    Faley, Michael I.
    Maslennikov, Yuri V.
    Koshelets, Valery P.
    Dunin-Borkowski, Rafal E.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [42] Two-channel high-T-c SQUID magnetometer for magnetocardiograms
    Moon, SH
    Oh, B
    Kim, HT
    Choi, YH
    Min, BC
    Lee, YH
    Kwon, HC
    Kim, JM
    Park, YK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1997, 31 (02) : 342 - 346
  • [43] Evaluation of the flaw depth using high-Tc SQUID
    Horng, HE
    Jeng, JT
    Yang, HC
    Chen, JC
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 367 (1-4): : 303 - 307
  • [44] Nondestructive Evaluation Using a High-Tc SQUID Microscope
    Faley, Michael I.
    Kostyurina, E. A.
    Diehle, P.
    Poppe, Ulrich
    Kovacs, A.
    Maslennikov, Yuri V.
    Koshelets, Valery P.
    Dunin-Borkowski, Rafal E.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [45] Moisture Content Evaluation Using Improved High-Tc SQUID-Based Rotating-Sample Magnetometer
    Sakai, Kenji
    Okamoto, Naohiro
    Watanabe, Yuuta
    Saari, Mohd
    Kiwa, Toshihiko
    Tsukada, Keiji
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [46] Ultra-Sensitive Contaminant Detection System Using High-Tc SQUID
    S. Tanaka
    T. Ohtani
    Y. Uchida
    Y. Hatsukade
    S. Suzuki
    Journal of Superconductivity and Novel Magnetism, 2015, 28 : 667 - 670
  • [47] Ultra-Sensitive Contaminant Detection System Using High-Tc SQUID
    Tanaka, S.
    Ohtani, T.
    Uchida, Y.
    Hatsukade, Y.
    Suzuki, S.
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2015, 28 (02) : 667 - 670
  • [48] Serial array high Tc SQUID magnetometer
    Lee, SG
    Huh, YS
    Park, GS
    Kim, IS
    Park, YK
    Park, JC
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 3347 - 3350
  • [49] Serial array high Tc SQUID magnetometer
    Korea Univ, Chungnam, Korea, Republic of
    IEEE Trans Appl Supercond, 2 pt 3 (3347-3350):
  • [50] Measurement of trapped flux distribution in a high-Tc superconductor using a flux-gate magnetometer
    Sasada, I.
    Oonaka, Y.
    Harada, K.
    Journal of Applied Physics, 1993, 73 (10 pt 2A):