Measurement of Rat Magnetocardiograms by Using a High-TC SQUID Magnetometer System

被引:3
|
作者
Kim, In-Seon [1 ]
Kwon, Hyuckchan [1 ]
Ahn, San [2 ]
Song, Jong-Hyun [2 ]
机构
[1] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
[2] Chungnam Natl Univ, Taejon 305764, South Korea
关键词
Biomagnetic measurement; high-T-C SQUID; magnetocardiography; rat; REPOLARIZATION;
D O I
10.1109/TASC.2010.2094994
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have measured biomagnetic signals in rat by using a high-T-C SQUID magnetometer system employing a small magnetically shielded box. For the rat cardiac magnetic field measurements, a healthy rat with body weight of about 350 g was anesthetized and fixed on a plastic xyz-stage in supine position inside the magnetically shielded box. We could obtain strong R-peak amplitude up to 56 pT with well defined P-, QRS-, T-wave, and ST-segment separating T-wave from QRS complex. We measured and analysed rat MCG waveforms for 5 x 5 grid measurements covering 60 mm x 60 mm area and 12 circular measurements centered at the heart position. This work demonstrates that the potential advantages of high-T-C SQUID magnetometer system in evaluating the rat MCG measurement for animal models of cardiac electrical activities.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 50 条
  • [1] Development of a rat biomagnetic measurement system using a high-TC SQUID magnetometer
    Kim, In-Seon
    Lee, Chul-Ho
    Lee, Yong-Ho
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (08):
  • [2] Development of a Mouse Biomagnetic Measurement System by Using a High-TC SQUID Magnetometer
    Kim, In-Seon
    Ahn, San
    Lee, Chul-Ho
    Lee, Yong-Ho
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 493 - 496
  • [3] High-Tc squid magnetometer system with active cancellation
    Kuriki, S
    Oyama, H
    Hayashi, A
    Washio, T
    Fujita, M
    Hirata, Y
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 48A AND B, 2002, 614 : 444 - 451
  • [4] Development of a high-Tc SQUID-based magnetometer system for MCG measurement
    Kuriki, S
    Oyama, H
    Hayashi, A
    Hirano, S
    Washio, T
    Matsuda, M
    Yokosawa, K
    IEICE TRANSACTIONS ON ELECTRONICS, 2002, E85C (03): : 670 - 676
  • [5] High-TC SQUID magnetometers for low noise measurements of magnetocardiograms
    Kim, IS
    Yu, KK
    Lee, YH
    Kim, KW
    Park, YK
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 652 - 655
  • [6] Magnetoencephalography using a multilayer high-Tc DC SQUID magnetometer
    Faley, M. I.
    Poppe, U.
    Dunin-Borkowski, R. E.
    Schiek, M.
    Boers, F.
    Chocholacs, H.
    Dammers, J.
    Eich, E.
    Shah, N. J.
    Ermakov, A. B.
    Slobodchikov, V. Yu
    Maslennikov, Yu V.
    Koshelets, V. P.
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 66 - 71
  • [7] SQUID MAGNETOMETER DESIGNED FOR HIGH-TC SUPERCONDUCTORS
    KOHL, M
    HARRISON, JP
    CRYOGENICS, 1991, 31 (05) : 369 - 372
  • [8] Mobile high-Tc DC SQUID magnetometer
    He, DF
    Yoshizawa, M
    PHYSICA B-CONDENSED MATTER, 2003, 329 : 1489 - 1490
  • [9] Mobile High-Tc SQUID System for MCG Measurement
    Oyama, Daisuke
    Kobayashi, Koichiro
    Yoshizawa, Masahito
    Uchikawa, Yoshinori
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 871 - 873
  • [10] HIGH-TC RF-SQUID MAGNETOMETER AND ITS APPLICATIONS
    XUE, SQ
    ZHANG, J
    LI, JZ
    YANG, PY
    WANG, CJ
    CRYOGENICS, 1990, 30 : 925 - 928