Overcoming challenges in single particle inductively coupled plasma mass spectrometry measurement of silver nanoparticles

被引:47
|
作者
Liu, Jingyu [1 ,2 ]
Murphy, Karen E. [2 ]
Winchester, Michael R. [2 ]
Hackley, Vincent A. [1 ]
机构
[1] NIST, Mat Measurement Sci Div, Mat Measurement Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
[2] NIST, Div Chem Sci, Mat Measurement Lab, 100 Bur Dr, Gaithersburg, MD 20899 USA
关键词
Size characterization; Single particle inductively coupled plasma mass spectrometry; Silver nanoparticle; Matrix effect; Sample treatment; DRINKING-WATER TREATMENT; ICP-MS; GOLD NANOPARTICLES; QUANTITATIVE-DETERMINATION; ENGINEERED NANOMATERIALS; SIZE DISTRIBUTIONS; ISOTOPE-DILUTION; NANO-SILVER; QUANTIFICATION; SULFIDATION;
D O I
10.1007/s00216-017-0530-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single particle ICP-MS has evolved rapidly as a quantitative method for determining nanoparticle size and number concentration at environmentally relevant exposure levels. Central to the application of spICP-MS is a commonly used, but not rigorously validated, calibration approach based on the measured transport efficiency and the response of ionic standards. In this work, we present a comprehensive and systematic study of the accuracy, precision and robustness of spICP-MS using the rigorously characterized reference material (RM) 8017 (Polyvinylpyrrolidone Coated Nominal 75 nm Silver Nanoparticles), recently issued by the National Institute of Standards and Technology (NIST). We report for the first time, statistically significant differences in frequency-based and size-based measures of transport efficiency with NIST RM 8013 Gold Nanoparticles and demonstrate that the size-based measure of transport efficiency is more robust and yields accurate results for the silver nanoparticle RM relative to TEM-based reference values. This finding is significant, because the frequency-based method is more widely applied. Furthermore, we demonstrate that the use of acidified ionic standards improves measurement of ICP-MS Ag response, but does not degrade the accuracy of the results for AgNP suspensions in water or various other diluents. Approaches for controlling AgNP dissolution were investigated and are shown to effectively improve particle stability in dilute suspensions required for spICP-MS analysis, while minimally affecting the measured intensity and allowing for more robust analysis. This study is an important and necessary advancement toward full validation and adoption of spICP-MS by the broader research community.
引用
收藏
页码:6027 / 6039
页数:13
相关论文
共 50 条
  • [21] Study on Silver Species Released from Silver Nanotextiles by Single Particle Inductively Coupled Plasma-Mass Spectrometry
    Gao, Ya
    Ge, Xiu-Jie
    Chen, Lan
    Liu, Ren-Xiao
    Guo, Yu-Ting
    Ge, Guang-Lu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (02) : 271 - 281
  • [22] Multifunctional microfluidic chips for the single particle inductively coupled plasma mass spectrometry analysis of inorganic nanoparticles
    Kajner, Gyula
    Keri, Albert
    Belteki, Adam
    Valkai, Sandor
    Der, Andras
    Geretovszky, Zsolt
    Galbacs, Gabor
    LAB ON A CHIP, 2022, 22 (14) : 2766 - 2776
  • [23] Isolation of Nanoparticles from Soil and Dust and Their Study by Single Particle Inductively Coupled Plasma Mass Spectrometry
    M. S. Ermolin
    P. S. Fedotov
    Journal of Analytical Chemistry, 2023, 78 : 1115 - 1124
  • [24] Isolation of Nanoparticles from Soil and Dust and Their Study by Single Particle Inductively Coupled Plasma Mass Spectrometry
    Ermolin, M. S.
    Fedotov, P. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 78 (09) : 1115 - 1124
  • [25] Characterization of platinum nanoparticles for fuel cell applications by single particle inductively coupled plasma mass spectrometry
    Lamsal, Ram P.
    Hineman, Aaron
    Stephan, Chady
    Tahmasebi, Sadaf
    Baranton, Steve
    Coutanceau, Christophe
    Jerkiewicz, Gregory
    Beauchemin, Diane
    ANALYTICA CHIMICA ACTA, 2020, 1139 : 36 - 41
  • [26] Single particle inductively coupled plasma mass spectrometry with and without flow injection for the characterization of nickel nanoparticles
    Lamsal, Ram P.
    Houache, Mohamed S. E.
    Williams, Andrew
    Baranova, Elena
    Jerkiewicz, Gregory
    Beauchemin, Diane
    ANALYTICA CHIMICA ACTA, 2020, 1120 : 67 - 74
  • [27] Determination of metallic nanoparticles in air filters by means single particle inductively coupled plasma mass spectrometry
    Torregrosa, Daniel
    Grindlay, Guillermo
    Guardia, Miguel de la
    Gras, Luis
    Mora, Juan
    TALANTA, 2023, 252
  • [28] Single particle inductively coupled plasma mass spectrometry for the analysis of inorganic engineered nanoparticles in environmental samples
    Laborda, Francisco
    Bolea, Eduardo
    Jimenez-Lamana, Javier
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 9 : 15 - 23
  • [29] Characterization and Determination of Selenium Nanoparticles in Dietary Supplements by Single Particle Inductively Coupled Plasma Mass Spectrometry
    Akbaba, Tugba Nur
    Alp, Orkun
    Alshana, Usama
    Ertas, Nusret
    FOOD ANALYTICAL METHODS, 2025, 18 (01) : 101 - 112
  • [30] Extraction Method Development for Quantitative Detection of Silver Nanoparticles in Environmental Soils and Sediments by Single Particle Inductively Coupled Plasma Mass Spectrometry
    Li, Lei
    Wang, Qiang
    Yang, Yuan
    Luo, Li
    Ding, Ru
    Yang, Zhao-Guang
    Li, Hai-Pu