High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography

被引:84
|
作者
Fain, SB [1 ]
King, BF [1 ]
Breen, JF [1 ]
Kruger, DG [1 ]
Riederer, SJ [1 ]
机构
[1] Mayo Clin, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
magnetic resonance (MR); contrast media; rapid imaging; vascular studies; renal angiography; renal arteries; MR; stenosis or obstruction;
D O I
10.1148/radiology.218.2.r01fe36481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a high-spatial-resolution three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiographic technique for detecting proximal and distal renal arterial stenosis. MATERIALS AND METHODS: Twenty-five patients underwent high-spatial-resolution small-field-of-view (FOV) 3D contrast-enhanced MR angiography of the renal arteries, which was followed several minutes later by more standard, large-FOV 3D contrast-enhanced MR angiography that included the distal aorta and iliac arteries. For both acquisitions, MR fluoroscopic triggering and an elliptic centric view order were used. Two readers evaluated the MR angiograms for grade and hemodynamic significance of renal arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of digital subtraction angiograms. RESULTS: The high-spatial-resolution small-FOV technique provided high sensitivity (97%) and specificity (92%) for the detection of renal arterial stenosis, including all four distal stenoses encountered. The portrayal of the segmental renal arteries was adequate for diagnosis in 19 (76%) of 25 patients. In 12% of the patients, impaired depiction of the segmental arteries was linked to motion. CONCLUSION: The combined high-spatial-resolution small-FOV and large-FOV MR angiographic examination provides improved spatial resolution in the region of the renal arteries while maintaining coverage of the abdominal aorta and iliac arteries.
引用
收藏
页码:481 / 490
页数:10
相关论文
共 50 条
  • [1] High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: Comparison with digital subtraction angiography and US
    Schoenberg, SO
    Rieger, J
    Weber, CH
    Michaely, HJ
    Waggershauser, T
    Ittrich, C
    Dietrich, O
    Reiser, MF
    RADIOLOGY, 2005, 235 (02) : 687 - 698
  • [2] Fibromuscular dysplasia of the main renal arteries: Comparison of contrast-enhanced MR angiography with digital subtraction angiography
    Willoteaux, Serge
    Faivre-Pierret, Matthieu
    Moranne, Olivier
    Lions, Christophe
    Bruzzi, John
    Finot, Mathilde
    Gaxotte, Virginia
    Mounier-Vehier, Claire
    Beregi, Jean-Paul
    RADIOLOGY, 2006, 241 (03) : 922 - 929
  • [3] Non-enhanced MR angiography of renal arteries: comparison with contrast-enhanced MR angiography
    Angeretti, M. G.
    Lumia, D.
    Cani, A.
    Barresi, M.
    Cardim, L. Nocchi
    Piacentino, F.
    Maresca, A. M.
    Novario, R.
    Genovese, E. A.
    Fugazzola, C.
    ACTA RADIOLOGICA, 2013, 54 (07) : 749 - 756
  • [4] Intracranial Arteriovenous Malformation: Comparison of Time-Resolved and High Spatial Resolution Contrast-Enhanced MR Angiography at 3 T With Digital Subtraction Angiography
    Srinivas, M. R.
    Singh, P.
    Gupta, V
    Khandelwal, N.
    Mathuriya, S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [5] Evaluation of vascular complications of pancreas transplantation with high-spatial-resolution contrast-enhanced MR angiography
    Hagspiel, Klaus D.
    Nandalur, Kiran
    Pruett, Timothy L.
    Leung, Daniel A.
    Angle, J. Fritz
    Spinosa, David J.
    Matsumoto, Alan H.
    Ahmed, Hossam
    Sanfey, Hilary A.
    Sawyer, Robert G.
    Burkholder, Brian
    Brayman, Kenneth L.
    RADIOLOGY, 2007, 242 (02) : 590 - 599
  • [6] Comparison of high resolution contrast enhanced MR angiography versus digital subtraction angiography in the evaluation of pancreas allografts
    Bozlar, Ugur
    Brayman, Kenneth
    Hagspiel, Klaus
    XENOTRANSPLANTATION, 2007, 14 (05) : 530 - 530
  • [7] Blood Pool Contrast-Enhanced MR Angiography With Correlation to Digital Subtraction Angiography
    Kowalski, J.
    Knuttinen, M.
    Mar, W.
    Khiatani, V
    Golden, M.
    Xie, K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [8] Advances in Contrast-Enhanced MR Angiography of the Renal Arteries
    Leiner, Tim
    Michaely, Henrik
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 561 - +
  • [9] Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    Herborn, CU
    Watkins, DM
    Runge, VM
    Gendron, JM
    Montgomery, ML
    Naul, LG
    RADIOLOGY, 2006, 239 (01) : 263 - 268
  • [10] Normal anterior spinal arteries within the cervical region: High-spatial-resolution contrast-enhanced three-dimensional MR angiography
    Sheehy, NP
    Boyle, GE
    Meaney, JFM
    RADIOLOGY, 2005, 236 (02) : 637 - 641