Non-enhanced MR angiography of renal arteries: comparison with contrast-enhanced MR angiography

被引:21
|
作者
Angeretti, M. G. [1 ]
Lumia, D. [1 ]
Cani, A. [1 ]
Barresi, M. [1 ]
Cardim, L. Nocchi [1 ]
Piacentino, F. [1 ]
Maresca, A. M. [2 ]
Novario, R. [3 ]
Genovese, E. A. [1 ]
Fugazzola, C. [1 ]
机构
[1] Insubria Univ, Osped Circolo & Fdn Macchi, Dept Radiol, Varese, Italy
[2] Insubria Univ, Osped Circolo & Fdn Macchi, Dept Internal Med, Varese, Italy
[3] Insubria Univ, Osped Circolo & Fdn Macchi, Dept Med Phys, Varese, Italy
关键词
Magnetic resonance angiography; renovascular hypertension; renal artery; STATE FREE-PRECESSION; DIGITAL-SUBTRACTION-ANGIOGRAPHY; DIAGNOSTIC PERFORMANCE; STENOSIS; INVERSION;
D O I
10.1177/0284185113482690
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The main causes of renal artery stenosis (RAS) are atherosclerosis and fibromuscular dysplasia. Despite contrast-enhanced magnetic resonance angiography (CE-MRA) being a safe and reliable method for diagnosis of RAS especially in young individuals, recently it has been possible to adopt innovative technologies that do not require paramagnetic contrast agents. Purpose: To assess the accuracy of steady-state free-precession (SSFP) non-contrast-enhanced magnetic resonance angiography (NC-MRA) by using a 1.5 T MR scanner for the detection of renal artery stenosis, in comparison with breath-hold CE-MRA as the reference standard. Material and Methods: Sixty-three patients (33 men, 30 women) with suspected renovascular hypertension (RVHT) were examined by a 1.5T MR scanner; NC-MRA with an electrocardiography (ECG)-gated SSFP sequence was performed in 58.7% (37/63) of patients; in 41.3% (26/63) of patients a respiratory trigger was used in addition to cardiac gating. CE-MRA, with a three-dimensional gradient echo (3D-GRE) T1-weighted sequence, was performed in all patients within the same session. Maximum intensity projection (MIP) image quality, number of renal arteries, and the presence of stenosis were assessed by two observers (independently for NC-MRA and together for CE-MRA). The agreement between NC-MRA and CE-MRA as well as the inter-observer reproducibility were calculated with Bland-Altman plots. Results: MIP image quality was considered better for NC-MRA. NC-MRA identified 143 of 144 (99.3%) arteries detected by CE-MRA (an accessory artery was not identified). Fourteen stenoses were detected by CE-MRA (11 atherosclerotic, 3 dysplastic) with four of 14 (28.5%) significant stenosis. Bland-Altman plot demonstrated an excellent concordance between NC-MRA and CE-MRA; particularly, the reader A evaluated correctly all investigated arteries, while over-estimation of two stenoses occurred for reader B. Regarding NC-MRA, inter-observer agreement was excellent. Conclusion: NC-MRA is a valid alternative to CE-MRA for the assessment of renal arteries.
引用
收藏
页码:749 / 756
页数:8
相关论文
共 50 条
  • [1] Advances in Contrast-Enhanced MR Angiography of the Renal Arteries
    Leiner, Tim
    Michaely, Henrik
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 561 - +
  • [2] Renal arteries: Comparison of steady-state free precession MR angiography and contrast-enhanced MR angiography
    Herborn, CU
    Watkins, DM
    Runge, VM
    Gendron, JM
    Montgomery, ML
    Naul, LG
    RADIOLOGY, 2006, 239 (01) : 263 - 268
  • [3] Fibromuscular dysplasia of the main renal arteries: Comparison of contrast-enhanced MR angiography with digital subtraction angiography
    Willoteaux, Serge
    Faivre-Pierret, Matthieu
    Moranne, Olivier
    Lions, Christophe
    Bruzzi, John
    Finot, Mathilde
    Gaxotte, Virginia
    Mounier-Vehier, Claire
    Beregi, Jean-Paul
    RADIOLOGY, 2006, 241 (03) : 922 - 929
  • [4] Contrast-enhanced MR angiography
    Bosmans, H
    Marchal, G
    RADIOLOGE, 1996, 36 (02): : 115 - 123
  • [5] Contrast-enhanced MR angiography
    J. H. Maki
    T. L. Chenevert
    M. R. Prince
    Abdominal Imaging, 1998, 23 : 469 - 484
  • [6] CONTRAST-ENHANCED MR ANGIOGRAPHY
    RUNGE, VM
    KIRSCH, JE
    LEE, C
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01): : 233 - 239
  • [7] Contrast-enhanced MR angiography
    Maki, JH
    Chenevert, TL
    Prince, MR
    ABDOMINAL IMAGING, 1998, 23 (05): : 469 - 484
  • [8] Non-enhanced, ECG-gated MR angiography of the pedal vasculature: comparison with contrast-enhanced MR angiography and digital subtraction angiography in peripheral arterial occlusive disease
    Tilman Schubert
    Martin Takes
    Markus Aschwanden
    Markus Klarhoefer
    Tanja Haas
    Augustinus L. Jacob
    David Liu
    Andreas Gutzeit
    Sebastian Kos
    European Radiology, 2016, 26 : 2705 - 2713
  • [9] Effect of contrast dilution on contrast-enhanced MR angiography of the aorta and renal arteries
    Jean-Pierre Laissy
    David Menegazzo
    Marie-Pierre Debray
    Sylvie Chillon
    Pascale Karila-Cohen
    Abdenasser Daikha
    Elisabeth Schouman-Claeys
    European Radiology, 2001, 11 : 1198 - 1205
  • [10] Non-enhanced, ECG-gated MR angiography of the pedal vasculature: comparison with contrast-enhanced MR angiography and digital subtraction angiography in peripheral arterial occlusive disease
    Schubert, Tilman
    Takes, Martin
    Aschwanden, Markus
    Klarhoefer, Markus
    Haas, Tanja
    Jacob, Augustinus L.
    Liu, David
    Gutzeit, Andreas
    Kos, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2705 - 2713