Water suppression in the human brain with hypergeometric RF pulses for single-voxel and multi-voxel MR spectroscopy

被引:4
|
作者
Chan, Kimberly L. [1 ,2 ,3 ]
Ouwerkerk, Ronald [2 ,4 ]
Barker, Peter B. [2 ,3 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[3] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
[4] NIDDK, Biomed & Metab Imaging Branch, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
brain; MRS; MRSI; water suppression; H-1-NMR SPECTROSCOPY; ANALYTIC SOLUTIONS; LIPID SUPPRESSION; BLOCH EQUATION; 3.0; TESLA; INVERSION;
D O I
10.1002/mrm.27133
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and investigate a novel water suppression sequence with hyper-geometric pulses at 3 T. Methods: Simulations were used to optimize the delays and amplitudes of 5 hyper-geometric prepulses, to minimize the residual water over a range of T-1 and B-1 values. Single-voxel data with hypergeometric water suppression (HGWS) prepulses were acquired in the centrum semiovale, 2 parietal regions, and insula of 7 subjects, and compared with VAPOR water suppression. Magnetic resonance spectroscopic imaging (MRSI) data using both VAPOR and HGWS prepulses were also collected and compared. Water suppression performance was calculated as the residual water peak height relative to the unsuppressed water peak. MRSI voxel-by-voxel comparison was performed by calculating the ratio between HGWS and VAPOR residual water peaks. Results: In simulations, HGWS and VAPOR are insensitive to B-1 and water T-1 variations, but with no B-1 variation, HGWS has a lower average residual water fraction (0.0033) than that of VAPOR (0.0091). In single-voxel acquisitions, HGWS performs better than VAPOR in all regions with a 2.3-fold to 5.7-fold lower residual water. In MRSI acquisitions, HGWS performs on average 2.3-fold better than VAPOR in 98.9% of the voxels. Conclusion: HGWS provides better water suppression than VAPOR in both single-voxel and multivoxel acquisitions with a shorter sequence duration.
引用
收藏
页码:1298 / 1306
页数:9
相关论文
共 50 条
  • [41] Brain tissues have single-voxel signatures in multi-spectral MRI
    German, Alexander
    Mennecke, Angelika
    Martin, Jan
    Hanspach, Jannis
    Liebert, Andrzej
    Herrler, Juergen
    Kuder, Tristan Anselm
    Schmidt, Manuel
    Nagel, Armin
    Uder, Michael
    Doerfler, Arnd
    Winkler, Juergen
    Zaiss, Moritz
    Laun, Frederik Bernd
    NEUROIMAGE, 2021, 234
  • [42] Single-voxel proton brain spectroscopy exam (PROBE/SV) in patients with primary brain tumors
    Tien, RD
    Lai, PH
    Smith, JS
    Lazeyras, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 201 - 209
  • [43] Assessment of different brain lesions using Single-Voxel Proton Magnetic Resonance Spectroscopy
    Ahmed, Negwa Gasim Mahgoub
    Elamin, Asma
    Gareeballah, Awadia
    Gameraddin, Moawia
    Abdelwahab, Babiker
    Khalifa, Sara
    Elhassan, Sawsan Mohammed
    BIOSCIENCE RESEARCH, 2020, 17 (03): : 1626 - 1632
  • [44] Single-voxel long TE 1H-MR spectroscopy of the normal brainstem and cerebellum
    Mascalchi, M
    Brugnoli, R
    Guerrini, L
    Belli, G
    Nistri, M
    Politi, LS
    Gavazzi, C
    Lolli, F
    Argenti, G
    Villari, N
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (05) : 532 - 537
  • [45] Diffusion-weighted imaging and single-voxel MR spectroscopy in a case of malignant cerebral lymphoma
    Ducreux, D
    Wu, RH
    Mikulis, DJ
    terBrugge, K
    NEURORADIOLOGY, 2003, 45 (12) : 865 - 868
  • [46] Differentiation between high-grade glioma and metastatic brain tumor using single-voxel proton MR spectroscopy
    Hideki Ishimaru
    Minoru Morikawa
    Soji Iwanaga
    Makio Kaminogo
    Makoto Ochi
    Kuniaki Hayashi
    European Radiology, 2001, 11 : 1784 - 1791
  • [47] Differentiation between high-grade glioma and metastatic brain tumor using single-voxel proton MR spectroscopy
    Ishimaru, H
    Morikawa, M
    Iwanaga, S
    Kaminogo, M
    Ochi, M
    Hayashi, K
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1784 - 1791
  • [48] Quantification of Muscle Fat in Patients with Low Back Pain: Comparison of Multi-Echo MR Imaging with Single-Voxel MR Spectroscopy
    Fischer, Michael A.
    Nanz, Daniel
    Shimakawa, Ann
    Schirmer, Timo
    Guggenberger, Roman
    Chhabra, Avneesh
    Carrino, John A.
    Andreisek, Gustav
    RADIOLOGY, 2013, 266 (02) : 555 - 563
  • [49] Diffusion-weighted imaging and single-voxel MR spectroscopy in a case of malignant cerebral lymphoma
    D. Ducreux
    R. H. Wu
    D. J. Mikulis
    K. terBrugge
    Neuroradiology, 2003, 45 : 865 - 868
  • [50] Multi-voxel MR spectroscopic imaging of the brain: utility in clinical setting-initial results
    Parmar, H
    Lim, TCC
    Yin, H
    Chua, V
    Khin, LW
    Raidy, T
    Hui, F
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (03) : 401 - 408