Water suppression in the human brain with hypergeometric RF pulses for single-voxel and multi-voxel MR spectroscopy

被引:4
|
作者
Chan, Kimberly L. [1 ,2 ,3 ]
Ouwerkerk, Ronald [2 ,4 ]
Barker, Peter B. [2 ,3 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[3] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
[4] NIDDK, Biomed & Metab Imaging Branch, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
brain; MRS; MRSI; water suppression; H-1-NMR SPECTROSCOPY; ANALYTIC SOLUTIONS; LIPID SUPPRESSION; BLOCH EQUATION; 3.0; TESLA; INVERSION;
D O I
10.1002/mrm.27133
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and investigate a novel water suppression sequence with hyper-geometric pulses at 3 T. Methods: Simulations were used to optimize the delays and amplitudes of 5 hyper-geometric prepulses, to minimize the residual water over a range of T-1 and B-1 values. Single-voxel data with hypergeometric water suppression (HGWS) prepulses were acquired in the centrum semiovale, 2 parietal regions, and insula of 7 subjects, and compared with VAPOR water suppression. Magnetic resonance spectroscopic imaging (MRSI) data using both VAPOR and HGWS prepulses were also collected and compared. Water suppression performance was calculated as the residual water peak height relative to the unsuppressed water peak. MRSI voxel-by-voxel comparison was performed by calculating the ratio between HGWS and VAPOR residual water peaks. Results: In simulations, HGWS and VAPOR are insensitive to B-1 and water T-1 variations, but with no B-1 variation, HGWS has a lower average residual water fraction (0.0033) than that of VAPOR (0.0091). In single-voxel acquisitions, HGWS performs better than VAPOR in all regions with a 2.3-fold to 5.7-fold lower residual water. In MRSI acquisitions, HGWS performs on average 2.3-fold better than VAPOR in 98.9% of the voxels. Conclusion: HGWS provides better water suppression than VAPOR in both single-voxel and multivoxel acquisitions with a shorter sequence duration.
引用
收藏
页码:1298 / 1306
页数:9
相关论文
共 50 条
  • [1] Single-Voxel MR Spectroscopy
    Payne, Geoffrey S.
    EMAGRES, 2015, 4 (03): : 709 - 719
  • [2] Effect of voxel position on single-voxel MR spectroscopy findings
    Ricci, PE
    Pitt, A
    Keller, PJ
    Coons, SW
    Heiserman, JE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (02) : 367 - 374
  • [3] Single-voxel proton MR spectroscopy in toluene abuse
    Aydin, K
    Sencer, S
    Ogel, K
    Genchellac, H
    Demir, T
    Minareci, O
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 777 - 785
  • [4] Single-voxel proton MR spectroscopy of nonneoplastic brain lesions suggestive of a neoplasm
    Krouwer, HGJ
    Kim, TA
    Rand, SD
    Prost, RW
    Haughton, VM
    Ho, KC
    Jaradeh, SS
    Meyer, GA
    Blindauer, KA
    Cusick, JF
    Morris, GL
    Walsh, PR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (09) : 1695 - 1703
  • [5] Single-voxel and multi-voxel spectroscopy yield comparable results in the normal juvenile canine brain when using 3 Tesla magnetic resonance imaging
    Lee, Alison M.
    Beasley, Michaela J.
    Barrett, Emerald D.
    James, Judy R.
    Gambino, Jennifer M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2018, 59 (05) : 577 - 586
  • [6] Systemic lupus erythematosus: Brain MR imaging and single-voxel hydrogen 1 MR spectroscopy
    Lim, MK
    Suh, CH
    Kim, HJ
    Cho, YK
    Choi, SH
    Kang, JH
    Park, W
    Lee, JH
    RADIOLOGY, 2000, 217 (01) : 43 - 49
  • [7] Assessment of Brain Water Content in Peripheral Inflammation by an Optimized Single-Voxel MR Spectroscopy Quantitation Technique
    Mumuni, Abdul Nashirudeen
    McLean, John
    Krishnadas, Rajeev
    Lopez-Gonzalez, Maria Rosario
    Cavanagh, Jonathan
    Condon, Barrie
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 91 - 96
  • [8] Classification of biopsy-confirmed brain tumors using single-voxel MR spectroscopy
    Meyerand, ME
    Pipas, JM
    Mamourian, A
    Tosteson, TD
    Dunn, JE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (01) : 117 - 123
  • [9] Navigated single-voxel proton spectroscopy of the human liver
    Tyszka, JM
    Silverman, JM
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) : 1 - 5
  • [10] Development of a cone-shape phantom for multi-voxel MR spectroscopy
    Woo, Dong-Cheol
    Kim, Bum-Soo
    Jung, So-Lyung
    Park, Hyo-Jin
    Rhim, Hyang-Shuk
    Jahng, Geon-Ho
    Choe, Bo-Young
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 162 (1-2) : 101 - 107