Agreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients

被引:14
|
作者
Asawaworarit, Rosepon [1 ]
Satitpitakul, Vannarut [1 ]
Taweekitikul, Parichart [1 ]
Pongpirui, Krit [2 ]
机构
[1] Chulalongkorn Univ, King Chulalongkorn Mem Hosp, Excellence Ctr Cornea & Limbal Stem Cell Transpla, Fac Med,Dept Ophthalmol, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Med, Bangkok, Thailand
来源
PLOS ONE | 2022年 / 17卷 / 05期
关键词
REPEATABILITY; ASTIGMATISM; EYES; RELIABILITY; KERATOMETRY;
D O I
10.1371/journal.pone.0268856
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate agreement of total corneal power (TCP) measured by swept-source anterior segment optical coherence tomography (CASIA 2), Scheimpflug tomography (Pentacam AXL), and swept-source optical biometer (IOLMaster 700) in normal and keratoconic patients. Methods This is a prospective observational study conducted at King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Biometric values were measured by each device for three times by two operators to evaluate repeatability and reproducibility of TCP. The agreement of TCP and other parameters including total corneal astigmatism, anterior keratometry, anterior corneal astigmatism, posterior keratometry, posterior corneal astigmatism, anterior chamber depth, white-to-white corneal diameter (WTW), central corneal thickness, and intraocular power were also evaluated. Results This study enrolled 100 healthy participants and 34 patients with keratoconus. The repeatability and reproducibility of TCP were high in all devices (ICC > 0.9). The agreement of TCP was excellent among three devices in both groups (ICC > 0.9). However, the agreement of TCP between CASIA 2 and IOLMaster 700 was slightly lower in healthy participants (ICC = 0.867) and keratoconic patients (ICC = 0.852) with mean differences of more than 1.0 diopter is clinically significant. Wider 95% limit of agreement were found in keratoconic eyes. Most of other parameters showed good to excellent agreement except WTW which showed poor to moderate agreement in both groups. IOL power showed clinically significant differences in patients with keratoconus. Conclusions The agreement of TCP measured by three devices was excellent in normal and keratoconic patients. However, TCP cannot be used interchangeably between devices.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry
    Tana-Sanz, Pedro
    Rodriguez-Carrillo, Maria Dolores
    Ruiz-Santos, Maria
    Montes-Mico, Robert
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (12) : 1219 - 1234
  • [22] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [23] Repeatability and agreement of two swept-source optical coherence tomographers and scheimpflug imaging for measurements of corneal curvature
    Cheng, Shiming
    Zhang, Jiasheng
    Zhou, Kaijing
    Li, Tiantian
    Lin, Junhai
    Yu, A. -Yong
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [24] Novel perspectives on swept-source optical coherence tomography
    Lavinsky F.
    Lavinsky D.
    International Journal of Retina and Vitreous, 2 (1)
  • [25] Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes
    Ardoy, Elisa Garcia
    Mateos, Nuria
    Roda, Laura
    Sierra, Oscar Torrado
    Baptista, Antonio M.
    Serra, Pedro M.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2023, 106 (07) : 783 - 792
  • [26] Biometry and intraocular power calculation using a swept-source optical coherence tomography: A repeatability and agreement study
    Hashemi, Hassan
    Miraftab, Mohammad
    Panahi, Parsa
    Asgari, Soheila
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2845 - 2850
  • [27] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [28] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer
    Tana-Rivero, Pedro
    Aguilar-Corcoles, Salvador
    Tello-Elordi, Cristina
    Pastor-Pascual, Francisco
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (04): : 488 - 495
  • [30] Agreement between a new swept-source optical coherence tomography (ss-OCT) and a Placido disc - Dual Scheimpflug ocular biometric devices
    Seo, Shiney
    McLintock, Cameron
    Niyazmand, Hamed
    Barrett, Graham
    McKelvie, James
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 880 - 880