Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival

被引:45
|
作者
Monin, Jean-Luc
Monchi, Mehran
Kirsch, Matthias E. W.
Petit-Eisenmann, Helene
Baleynaud, Serge
Chauvel, Christophe
Metz, Damien
Adams, Catherine
Quere, Jean-Paul
Gueret, Pascal
Tribouilloy, Christophe
机构
[1] Hop Henri Mondor, AP HP, Dept Cardiol, F-94010 Creteil, France
[2] Hop Henri Mondor, AP HP, Dept Cardiac Surg, F-94010 Creteil, France
[3] Inst Jacques Monod, Dept Intens Care Med, Massy, France
[4] Univ Hosp, Dept Cardiac Surg, Strasbourg, France
[5] Gen Hosp, Lorient, France
[6] Clin St Augustin, Bordeaux, France
[7] Univ Hosp, Reims, France
[8] Gen Hosp, Argenteuil, France
[9] Univ Hosp, Amiens, France
关键词
valves; stenosis; surgery; prognosis;
D O I
10.1093/eurheartj/ehm393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To assess the prognostic impact of prosthesis-patient mismatch (PPM) in a large consecutive series of patients operated for low-gradient aortic stenosis (AS). Methods and results Outcomes after surgery for tow-gradient AS were prospectively assessed in 152 consecutive patients from seven institutions. There were 113 men (74%); mean age was 72 years (64-76); valve area, 0.7 cm(2) (0.6-0.8); Left ventricular (LV) ejection fraction 0.31 (0.25-0.37) and baseline mean transaortic pressure gradient (MPG), 30 mmHg (25-35) Among 139 patients with available prosthetic valve effective orifice area (EOA), PPM (defined by an indexed EOA <= 0.85 cm(2)/m(2)) was present in 79 patients (57%) and had no significant impact on post-operative mortality. Independent predictors of overall mortality were LV contractile reserve [hazard ratio (HR) 0.52; 95% confidence interval (Cl) 0.35-0.78; P = 0.002], associated coronary artery bypass grafting (HR 1.87; 95% Cl 1.24-2.82; P = 0.003), baseline MPG (per 1 mmHg decrease to 10 mmHg; HR 1.03; 95% Cl 1.01 -1.06; P = 0.021), previous cancer (HR 2.13; 95% Cl 1.05-4.29; P = 0.037), and logistic EuroSCORE (per 1% increase; HR 1.02; 95% Cl 1.01-1.04; P = 0.040). Conclusion In this large multicentre series of patients with low-gradient AS, we found that PPM (moderate in most cases) had no influence on post-operative mortality. Therefore, the performance of more complex interventions in order to avoid moderate PPM may not be justified in the setting of low-gradient AS, because their higher risk probably outweighs the expected benefit.
引用
收藏
页码:2620 / 2626
页数:7
相关论文
共 50 条
  • [41] Impact of Pre-existent Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures
    dos Santos, Matheus Simonato
    Pibarot, Philippe
    Barbanti, Marco
    Linke, Axel
    Kornowski, Ran
    Rudolph, Tanja
    Aldea, Gabriel
    Mennuni, Marco
    Iadanza, Alessandro
    Amrane, Hafid
    Gaia, Diego
    Kim, Won
    Napodano, Massimo
    Baumbach, Hardy
    Finkelstein, Ariel
    Kobayashi, Junjiro
    Brecker, Stephen
    Don, Creighton
    Cerillo, Alfredo
    Unbehaun, Axel
    Attias, David
    Nejjari, Mohammed
    Jones, Noah
    Tchetche, Didier
    Philippart, Raphael
    Spargias, Konstantinos
    Maria Hernandez, Jose
    Latib, Azeem
    Dvir, Danny
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B69 - B69
  • [42] PROSTHESIS-PATIENT MISMATCH IS NOT SYNONYMOUS WITH ELEVATED TRANSVALVULAR PRESSURE GRADIENT
    Ternacle, Julien
    Pibarot, Philippe
    JTCVS OPEN, 2021, 8 : 242 - 243
  • [43] Commentary: Betting the trifecta: Gradient, prosthesis-patient mismatch, and durability
    Hicks, George L.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (04): : 1040 - 1040
  • [44] Prevalence and Long-Term Outcome of Aortic Prosthesis-Patient Mismatch in Patients With Paradoxical Low-Flow Severe Aortic Stenosis
    Mohty, Dania
    Boulogne, Cyrille
    Magne, Julien
    Pibarot, Philippe
    Echahidi, Najmeddine
    Cornu, Elisabeth
    Dumesnil, Jean
    Laskar, Marc
    Virot, Patrice
    Aboyans, Victor
    CIRCULATION, 2014, 130 (11) : S25 - +
  • [45] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [46] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [47] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [48] Different incidence and implications of prosthesis-patient mismatch after aortic valve replacement for aortic insufficiency versus aortic stenosis
    Price, J.
    Chan, V.
    Kulik, A.
    Ressler, L.
    Bedard, P.
    Mesana, T. G.
    Ruel, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 133C - 133C
  • [49] A case of mismatch prosthesis-patient with low gradient unmasked after cardiac resynchronization therapy
    Hernandez Jimenez, Veronica
    Saavedra, J.
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (03): : 155 - 157
  • [50] Prosthesis-patient mismatch after transcatheter aortic valve implantation
    Leone, Pier Pasquale
    Pagnesi, Matteo
    Regazzoli, Damiano
    Latib, Azeem
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 26S - 34S