Feasibility study of a dosimeter for in vivo measurements of the absolute dose delivered in high dose rate brachytherapy

被引:2
|
作者
Carrara, M. [1 ]
Gambarini, G. [2 ,3 ]
Borroni, M. [1 ]
Tomatis, S. [1 ]
Cerrotta, A. [4 ]
Fallai, C. [4 ]
Olmi, P. [4 ]
Zonca, G. [1 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Med Phys Unit, I-20133 Milan, Italy
[2] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
[3] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
[4] Fdn IRCCS Ist Nazl Tumori, Radiotherapy Unit, I-20133 Milan, Italy
关键词
GEL-LAYER DOSIMETRY; PERSPECTIVES;
D O I
10.1393/ncb/i2010-10878-2
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiation doses delivered to the patient during high dose rate brachytherapy treatments are susceptible to many inaccuracies and may not accurately match the planned doses. In vivo dosimetry is a reliable solution to compare planned and delivered dose distributions, representing therefore a valid tool to increment treatment accuracy. In this study, dosimetric catheters were developed in laboratory and optimized to be used for in vivo measurements of high close rate brachytherapy treatments. Measurements were performed in different irradiation configurations with ad hoc developed phantoms. Preliminary measurements of dose distributions achieved with a 6MV linear accelerator showed a high linear response of the dosimetric catheters with the delivered dose. Moreover, measurements performed with the brachytherapy high dose rate remote afterloading device provided with an Ir-192 radioactive source showed high accordance between planned dose and dose measured with the dosimetric catheters at 1 mm 3 spatial resolution. Results show that dosimetric catheters are valid candidates for performing in-vivo linear dosimetry in HDR brachytherapy, representing an innovative tool that could help to significantly increase safety and accuracy in the brachytherapy treatments delivery. Eventually, these improvements might conduce to the best achievable therapeutic results, that is higher survival and recovery rates of the patients.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 50 条
  • [41] High-dose-rate brachytherapy and pulsed brachytherapy
    Mazeron, JJ
    EUROCANCER 2002, 2002, : 57 - 58
  • [42] In vivo urethral dose measurements:: A method as verify high dose rate prostate treatments
    Brezovich, IA
    Duan, J
    Pareek, PN
    Fiveash, J
    Ezekiel, M
    MEDICAL PHYSICS, 2000, 27 (10) : 2297 - 2301
  • [43] In-Vivo Prostate Brachytherapy Absorbed Dose Measurements
    Gueye, P.
    Velasco, C.
    Keppel, C.
    Murphy, B.
    Sinesi, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [44] High dose rate versus low dose rate brachytherapy in the treatment of tongue carcinoma - a radiobiological study
    Petera, J.
    Matula, P.
    Paluska, P.
    Sirak, I.
    Macingova, Z.
    Kasaova, L.
    Frgala, T.
    Hodek, M.
    Vosmik, M.
    NEOPLASMA, 2009, 56 (02) : 163 - 168
  • [45] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [46] Intraosseous High Dose Rate Brachytherapy (HDR) with Intramedullary Nailing for Long Bone Metastases - A Feasibility Study
    Gannavarapu, Bhavani
    Hassan-Rezaeian, Nima
    ONeill, David
    Hrycushko, Brian
    Folkert, Michael
    Callan, Alexandra
    Timmerman, Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (02): : E53 - E53
  • [47] In-Phantom Calibration of High Dose Rate Ir-192 Brachytherapy Source - A Feasibility Study
    Mandiram, Kuppuswamy
    Senthil, G.
    Sundaram, Visalatchi
    Muthulingam, S.
    Karthik, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [48] Effect of air cavities on the dose delivered to the lung during high-dose brachytherapy
    Ambrosi, RM
    Watterson, JIW
    Nam, T
    Keddy, RJ
    BIOLOGICAL TRACE ELEMENT RESEARCH, 1999, 71-2 (1) : 499 - 507
  • [49] Effect of air cavities on the dose delivered to the lung during high-dose brachytherapy
    Richard M. Ambrosi
    John I. W. Watterson
    Tom Nam
    Rex J. Keddy
    Biological Trace Element Research, 1999, 71-72 : 499 - 507
  • [50] Real-time in vivo dosimetry in high dose rate prostate brachytherapy
    Mason, Josh
    Mamo, Arielle
    AI-Qaisieh, Bashar
    Henry, Ann M.
    Bownes, Peter
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 333 - 338