Reduced irradiation time in slow-curing of resin composite using an intensity-changeable light source

被引:2
|
作者
Abo, T
Uno, S
Tagami, J
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Div Oral Hlth Sci, Dept Restorat Sci,Sect Cariol & Operat Dent,Bunky, Tokyo, Japan
[2] Toranomon Gen Hosp, Dept Dent, Minato Ku, Tokyo 1058570, Japan
关键词
resin composite; slow-curing; polymerization;
D O I
10.4012/dmj.24.195
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Possibility to shorten the total irradiation time in slow-curing with an intensity-changeable light source, Curetron 7 (CT-7), was investigated for four hybrid-type resin composites. Irradiation condition with CT-7 was assigned as 10 or 20 seconds at low light intensity (230 mW/cm(2)) and followed by 20 or 10 seconds at high intensity (600 mW/cm(2)) respectively (i.e., a total of 30 seconds). For a reference, irradiation was carried out for 30 seconds using a halogen lamp (900 mW/cm(2)). After irradiation, mechanical properties of the cured composites - in terms of microhardness and flexural strength - were evaluated. Also, cavity adaptation was examined in standardized, cylindrical dentin cavities treated with an adhesive system. Compared to the reference irradiation, slow-curing with CT-7 produced acceptable mechanical properties and better adaptation. These results suggested that total exposure time of slow-curing with CT-7 could be shortened to 30 seconds.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [21] Correlation between light intensity exposure time on the hardness of composite resin.
    Sobrinho, LC
    DeGoes, MF
    Consani, S
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2218 - 2218
  • [22] Ultra-fast light-curing resin composite with increased conversion and reduced monomer elution
    Randolph, Luc D.
    Palin, William M.
    Bebelman, Sabine
    Devaux, Jacques
    Gallez, Bernard
    Leloup, Gaetane
    Leprince, Julian G.
    DENTAL MATERIALS, 2014, 30 (05) : 594 - 604
  • [23] Adhesion to dentin of a self-curing composite resin by using a light-curing adhesive system.
    Angerame, D.
    Biasotto, M.
    Di Lenarda, R.
    Visintini, E.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B238 - B238
  • [24] Influence of the Light-Curing Unit, Storage Time and Shade of a Dental Composite Resin on the Fluorescence
    Queiroz, R. S.
    Bandeca, M. C.
    Calixto, L. R.
    Gaiao, U.
    Cuin, A.
    Porto-Neto, S. T.
    LASER PHYSICS, 2010, 20 (07) : 1647 - 1653
  • [25] New-generation curing units and short irradiation time: The degree of conversion of microhybrid composite resin
    Scotti, Nicola
    Venturello, Alberto
    Migliaretti, Giuseppe
    Pera, Francesco
    Pasqualini, Damiano
    Geobaldo, Francesco
    Berutti, Elio
    QUINTESSENCE INTERNATIONAL, 2011, 42 (08): : E89 - U3
  • [26] Time dependence of composite shrinkage using halogen and LED light curing
    Uhl, A
    Mills, RW
    Rzanny, AE
    Jandt, KD
    DENTAL MATERIALS, 2005, 21 (03) : 278 - 286
  • [27] Effects of light intensity and curing time of the newest LED Curing units on the diametral tensile strength of microhybrid composite resins
    Ariani, D.
    Herda, E.
    Eriwati, Y. K.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [28] Effect of the curing time by using high intensity light on bond strength to dentine
    Katahira, N
    Njnai, J
    Tagami, J
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1376 - 1376
  • [29] Correlation between light intensity-exposure time on the hardness of composite resin.
    Sobrinho, LC
    DeGoes, MF
    Consani, S
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1092 - 1092
  • [30] Influence of curing tip distance on resin composite Knoop Hardness Number, using three different light curing units
    Caldas, DBM
    Almeida, JB
    Correr-Sobrinho, L
    Sinhoreti, MAC
    Consani, S
    OPERATIVE DENTISTRY, 2003, 28 (03) : 315 - 320