Reduced irradiation time in slow-curing of resin composite using an intensity-changeable light source

被引:2
|
作者
Abo, T
Uno, S
Tagami, J
机构
[1] Tokyo Med & Dent Univ, Grad Sch, Div Oral Hlth Sci, Dept Restorat Sci,Sect Cariol & Operat Dent,Bunky, Tokyo, Japan
[2] Toranomon Gen Hosp, Dept Dent, Minato Ku, Tokyo 1058570, Japan
关键词
resin composite; slow-curing; polymerization;
D O I
10.4012/dmj.24.195
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Possibility to shorten the total irradiation time in slow-curing with an intensity-changeable light source, Curetron 7 (CT-7), was investigated for four hybrid-type resin composites. Irradiation condition with CT-7 was assigned as 10 or 20 seconds at low light intensity (230 mW/cm(2)) and followed by 20 or 10 seconds at high intensity (600 mW/cm(2)) respectively (i.e., a total of 30 seconds). For a reference, irradiation was carried out for 30 seconds using a halogen lamp (900 mW/cm(2)). After irradiation, mechanical properties of the cured composites - in terms of microhardness and flexural strength - were evaluated. Also, cavity adaptation was examined in standardized, cylindrical dentin cavities treated with an adhesive system. Compared to the reference irradiation, slow-curing with CT-7 produced acceptable mechanical properties and better adaptation. These results suggested that total exposure time of slow-curing with CT-7 could be shortened to 30 seconds.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [1] Effect of slow-curing on cavity wall adaptation using a new intensity-changeable light source
    Uno, S
    Tanaka, T
    Natsuizaka, A
    Abo, T
    DENTAL MATERIALS, 2003, 19 (02) : 147 - 152
  • [2] Microhardness of resin composites cured with an intensity-changeable light source.
    Abo, T
    Uno, S
    Tanaka, T
    Sano, H
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A330 - A330
  • [3] Light-curing time and light intensity's influence on composite resin's hardness.
    Dannheimer, MFG
    Marais, JT
    Germishuys, PJ
    Becker, LH
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1272 - 1272
  • [4] The curing of composite resin using a plasma curing light.
    Louca, C
    Millar, BJ
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1060 - 1060
  • [5] The Influence of Composite Resin Type and Light Curing Source on the Microleakage of Composite Restorations
    Dacic, Stefan
    Karuntanovic, Tamara
    Miljkovic, Nikola
    Dacic, Milica
    Dacic-Simonovic, Dragica
    Mitic, Aleksandar
    ACTA FACULTATIS MEDICAE NAISSENSIS, 2018, 35 (04) : 337 - 344
  • [6] Effect of the curing light intensity on the biocompatibility and flexural strength of a composite resin
    de Leon, Elisa
    Teske, Ana Paula
    Pais, Belen
    Grazioli, Guillermo
    ODONTOESTOMATOLOGIA, 2022, 24 (40):
  • [7] Microhardness and microleakage of composite resin according to the change of curing light intensity.
    Shin, DH
    Cho, KM
    Park, SM
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A88 - A88
  • [8] Acceleration of curing of resin composite at the bottom surface using slow-start curing methods
    Yoshikawa, Takako
    Morigami, Makoto
    Sadr, Alireza
    Tagami, Junji
    DENTAL MATERIALS JOURNAL, 2013, 32 (06) : 999 - 1004
  • [9] Effect of distance from light source on the curing of composite resin, in-vitro.
    Dunne, SM
    Mokhtari, M
    Millar, BJ
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1066 - 1066
  • [10] Effect of different intensity light curing modes on microleakage of two resin composite restorations
    Barros, GKP
    Aguiar, FHB
    Santos, AJS
    Lovadino, JR
    OPERATIVE DENTISTRY, 2003, 28 (05) : 642 - 646