Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI

被引:16
|
作者
Park, JB
Santos, JM
Hargreaves, BA
Nayak, KS
Sommer, G
Hu, BS
Nishimura, DG
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[2] Univ So Calif, Dept Elect Engn, Los Angeles, CA 90089 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Palo Alto Med Fdn, Palo Alto, CA USA
关键词
renal; vascular; flow; fast imaging; phase-contrast; spiral;
D O I
10.1002/jmri.20325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. Materials and Methods: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. Results: Rapid USPC scans produced reproducible RABF measurements (SD <= 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (< 50-65%) than the normal RABF rates. Conclusion: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [21] Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging
    Stock, KW
    Wetzel, SG
    Lyrer, PA
    Radü, EW
    EUROPEAN RADIOLOGY, 2000, 10 (11) : 1795 - 1800
  • [22] Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging
    de Haan, MW
    Kouwenhoven, M
    Kessels, AGH
    van Engelshoven, JMA
    EUROPEAN RADIOLOGY, 2000, 10 (07) : 1133 - 1137
  • [23] Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging
    M. W. de Haan
    M. Kouwenhoven
    A. G. H. Kessels
    J. M. A. van Engelshoven
    European Radiology, 2000, 10 : 1133 - 1137
  • [24] Reproducibility of phase-contrast MRI in the coronary artery: towards noninvasive pressure gradient measurement and quantification of fractional flow reserve
    Zixin Deng
    Qi Yang
    Xiaoming Bi
    Zhaoyang Fan
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [25] NORMAL RENAL BLOOD-FLOW MEASUREMENT USING PHASE-CONTRAST CINE MAGNETIC-RESONANCE-IMAGING
    SOMMER, G
    NOORBEHESHT, B
    PELC, N
    JAMISON, R
    PINEVICH, AJ
    NEWTON, L
    MYERS, B
    INVESTIGATIVE RADIOLOGY, 1992, 27 (06) : 465 - 470
  • [26] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Peng, Shin-Lei
    Shih, Cheng-Ting
    Huang, Chiun-Wei
    Chiu, Shao-Chieh
    Shen, Wu-Chung
    SCIENTIFIC REPORTS, 2017, 7
  • [27] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Shin-Lei Peng
    Cheng-Ting Shih
    Chiun-Wei Huang
    Shao-Chieh Chiu
    Wu-Chung Shen
    Scientific Reports, 7
  • [28] Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI
    Petersson, Sven
    Dyverfeldt, Petter
    Sigfridsson, Andreas
    Lantz, Jonas
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1249 - 1255
  • [29] Blood flow quantification in adults by phase-contrast MRI combined with SENSE -: a validation study
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) : 361 - 369
  • [30] Automatic and Reproducible Positioning of Phase-Contrast MRI for the Quantification of Global Cerebral Blood Flow
    Liu, Peiying
    Lu, Hanzhang
    Filbey, Francesca M.
    Pinkham, Amy E.
    McAdams, Carrie J.
    Adinoff, Bryon
    Daliparthi, Vamsi
    Cao, Yan
    PLOS ONE, 2014, 9 (05):