Preliminary study of silica aerogel as a gas-equivalent material in ionization chambers

被引:1
|
作者
Caresana, M. [1 ]
Zorloni, G. [1 ]
机构
[1] Politecn Milan, Dept Energy, Via Lambruschini 4, I-20156 Milan, Italy
关键词
Silica aerogel; Ionization chambers; Trapping-Detrapping mechanisms; SURFACE; SIO2;
D O I
10.1016/j.nima.2017.08.016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since about two decades, a renewed interest on aerogels has risen. These peculiar materials show fairly unique properties. Thus, they are under investigation for both scientific and commercial purposes and new optimized production processes are studied. In this work, the possibility of using aerogel in the field of radiation detection is explored. The idea is to substitute the gas filling in a ionization chamber with the aerogel. The material possesses a density about 100 times greater than ambient pressure air. Where as the open-pore structure should allow the charge carriers to move freely. Small hydrophobic silica aerogel samples were studied. A custom ionization chamber, capable of working both with aerogel or in the classic gas set up, was built. The response of the chamber in current mode was investigated using an X-ray tube. The results obtained showed, under proper conditions, an enhancement of about 60 times of the current signal in the aerogel configuration with respect to the classic gas one. Moreover, some unusual behaviours were observed, i.e. time inertia of the signal and super-/sub-linear current response with respect to the dose rate. While testing high electric fields, aerogel configuration seemed to enhance the Townsend's effects. In order to represent the observed trends, a trapping-detrapping model is proposed, which is capable to predict semi-empirically the steady state currents measured. The time evolution of the signal is semi-quantitatively represented by the same model. The coefficients estimated by the fits are in agreement with similar trapping problems in the literature. In particular, a direct comparison between the benchmark of the FET silica gates and aerogel case endorses the idea that the same type of phenomenon occurs in the studied case. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 24 条
  • [21] Ni-Ce-OMS-2 material: preparation and preliminary catalytic-study on removing ethanol in the gas phase
    Nguyen, G. H.
    Dang-Hung, Q. L.
    Tran, T. P.
    Nguyen, D., V
    Nguyen, L. Q.
    Tran-Thuy, T. M.
    GLOBAL NEST JOURNAL, 2023, 25 (06): : 68 - 72
  • [22] Comparative study of matrix-assisted laser desorption/ionization and gas chromatography for quantitative determination of cocoa butter and cocoa butter equivalent triacylglycerol composition
    Guyon, F
    Absalon, C
    Eloy, A
    Salagoity, MH
    Esclapez, M
    Medina, B
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (20) : 2317 - 2322
  • [23] Selective Determination of n-Hexane and Methyl Ethyl Ketone (MEK) in Urine by Magnetic-Silica Aerogel-Based Molecularly Imprinted Polymers (MIPs) with Gas Chromatography - Flame Ionization Detection (GC-FID)
    Vahabi, Masoomeh
    Ebrahimzadeh, Homeira
    Zendehdel, Rezvan
    Jalilian, Niloofar
    Khodakarim, Soheila
    ANALYTICAL LETTERS, 2023, 56 (08) : 1292 - 1311
  • [24] QUANTITATION OF POLYCHLORINATED BIPHENYL RESIDUES BY ELECTRON-CAPTURE GAS-LIQUID-CHROMATOGRAPHY - REFERENCE MATERIAL CHARACTERIZATION AND PRELIMINARY-STUDY
    SAWYER, LD
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1978, 61 (02): : 272 - 281