Simultaneous Measurement of Refractive Index and Temperature Based on Surface Plasmon Resonance Sensors

被引:45
|
作者
Xiao, Feng [1 ]
Michel, David [1 ]
Li, Guangyuan [2 ]
Xu, Anshi [2 ]
Alameh, Kamal [1 ]
机构
[1] Edith Cowan Univ, Dept Electron Sci Res Inst, Joondalup 6027, Australia
[2] Peking Univ, Dept Elect, Beijing 100871, Peoples R China
关键词
Optical sensor; surface plasmon resonance; SPECTROSCOPY;
D O I
10.1109/JLT.2014.2348999
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Although the surface Plasmon resonance (SPR) sensor is a mature technology, currently, the sample temperature needs to be carefully considered and controlled because SPR signals vary with temperature. This poses a large challenge in the applications where the sample temperature changes during measurement or an SPR sensor operates in different environmental temperatures. This paper proposes and experimentally demonstrates, for the first time to our knowledge, a solution to simultaneously measuring refractive index and temperature based on conventional SPR sensors, thus, not only requiring no temperature control/calibration during the measurement but also enabling SPR sensors for in-situ operations.
引用
收藏
页码:4169 / 4173
页数:5
相关论文
共 50 条
  • [31] Overview of refractive index sensors comprising photonic crystal fibers based on the surface plasmon resonance effect [Invited]
    Liu, Chao
    Lu, Jingwei
    Liu, Wei
    Wang, Famei
    Chu, Paul K.
    CHINESE OPTICS LETTERS, 2021, 19 (10)
  • [32] High sensitivity photonic crystal fiber temperature and refractive index sensor based on surface plasmon resonance
    Zhenhua Du
    Yuzhao Li
    Huilong Liu
    Jing Xia
    Jiaxin He
    Feifei Wei
    Yanfei Lü
    Indian Journal of Physics, 2023, 97 : 2821 - 2826
  • [33] Surface Plasmon Resonance Based Temperature Sensors in Liquid Environment
    Ibrahim, Joyce
    Al Masri, Mostafa
    Verrier, Isabelle
    Kampfe, Thomas
    Veillas, Colette
    Celle, Frederic
    Cioulachtjian, Serge
    Lefevre, Frederic
    Jourlin, Yves
    SENSORS, 2019, 19 (15)
  • [34] High sensitivity photonic crystal fiber temperature and refractive index sensor based on surface plasmon resonance
    Du, Z.
    Li, Y.
    Liu, H.
    Xia, J.
    He, J.
    Wei, F.
    Lu, Y.
    INDIAN JOURNAL OF PHYSICS, 2023, 97 (09) : 2821 - 2826
  • [35] Refractive index and temperature sensing based on surface plasmon resonance fabricated on a side-polished fiber
    Chen, Xiaolong
    Luo, Yunhan
    Xu, Mengyun
    Zhang, Yilong
    He, Yonghong
    Tang, Jieyuan
    Yu, Jianhui
    Zhang, Jun
    Chen, Zhe
    Guangxue Xuebao/Acta Optica Sinica, 2014, 34 (02):
  • [36] High precision measurement of air refractive index using surface plasmon resonance sensor
    Chen, QH
    Wu, J
    Yin, CY
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2002, : 386 - 390
  • [37] Noninvasive measurement of the refractive index of cell organelles using surface plasmon resonance microscopy
    Hassani, Hossein
    Kreysing, Eva
    OPTICS LETTERS, 2019, 44 (06) : 1359 - 1362
  • [38] A Dual-Channel Surface Plasmon Resonance Sensor for the Liquid Refractive Index and Temperature Measurement Based on Hollow-Core Fiber
    Zhang, Qi
    Liu, Hailian
    Li, Bin
    Zhang, Fan
    Yan, Xin
    Zhang, Xuenan
    Wang, Fang
    Cheng, Tonglei
    IEEE SENSORS JOURNAL, 2022, 22 (08) : 7785 - 7791
  • [39] Determination of near surface refractive index of graded-index waveguides based on surface plasmon resonance
    Zhu, HD
    Ding, Y
    Cao, ZQ
    Shen, QS
    OPTICS COMMUNICATIONS, 2005, 246 (4-6) : 331 - 336
  • [40] Simultaneous determination of refractive index and absorbance spectra of chemical samples using surface plasmon resonance
    Univ of Washington, Seattle, United States
    Sens Actuators, B Chem, 1 -3 pt 2 (747-749):