Polarity Sensitivity of Human Auditory Nerve Fibers Based on Pulse Shape, Cochlear Implant Stimulation Strategy and Array

被引:12
|
作者
Heshmat, Amirreza [1 ,2 ]
Sajedi, Sogand [1 ]
Schrott-Fischer, Anneliese [2 ]
Rattay, Frank [1 ]
机构
[1] Vienna Univ Technol, Inst Anal & Sci Comp, Vienna, Austria
[2] Med Univ Innsbruck, Dept Otorhinolaryngol, Lab Inner Ear Biol, Innsbruck, Austria
基金
奥地利科学基金会;
关键词
cochlear implant; computational model; electrical stimulation; finite element model; polarity sensitivity; auditory nerve; pulse shape; cochlear implant stimulation strategy; ELECTRODE-NEURON INTERFACE; AMPLITUDE RATIO PAR; ELECTRICAL-STIMULATION; SPEECH-PERCEPTION; STIMULUS POLARITY; TRIPHASIC PULSES; DETECTION THRESHOLDS; CHANNEL INTERACTION; ACTION-POTENTIALS; MUSIC PERCEPTION;
D O I
10.3389/fnins.2021.751599
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Neural health is of great interest to determine individual degeneration patterns for improving speech perception in cochlear implant (CI) users. Therefore, in recent years, several studies tried to identify and quantify neural survival in CI users. Among all proposed techniques, polarity sensitivity is a promising way to evaluate the neural status of auditory nerve fibers (ANFs) in CI users. Nevertheless, investigating neural health based on polarity sensitivity is a challenging and complicated task that involves various parameters, and the outcomes of many studies show contradictory results of polarity sensitivity behavior. Our computational study benefits from an accurate three-dimensional finite element model of a human cochlea with realistic human ANFs and determined ANF degeneration pattern of peripheral part with a diminishing of axon diameter and myelination thickness based on degeneration levels. In order to see how different parameters may impact the polarity sensitivity behavior of ANFs, we investigated polarity behavior under the application of symmetric and asymmetric pulse shapes, monopolar and multipolar CI stimulation strategies, and a perimodiolar and lateral CI array system. Our main findings are as follows: (1) action potential (AP) initiation sites occurred mainly in the peripheral site in the lateral system regardless of stimulation strategies, pulse polarities, pulse shapes, cochlear turns, and ANF degeneration levels. However, in the perimodiolar system, AP initiation sites varied between peripheral and central processes, depending on stimulation strategies, pulse shapes, and pulse polarities. (2) In perimodiolar array, clusters formed in threshold values based on cochlear turns and degeneration levels for multipolar strategies only when asymmetric pulses were applied. (3) In the perimodiolar array, a declining trend in polarity (anodic threshold/cathodic threshold) with multipolar strategies was observed between intact or slight degenerated cases and more severe degenerated cases, whereas in the lateral array, cathodic sensitivity was noticed for intact and less degenerated cases and anodic sensitivity for cases with high degrees of degeneration. Our results suggest that a combination of asymmetric pulse shapes, focusing more on multipolar stimulation strategies, as well as considering the distances to the modiolus wall, allows us to distinguish the degeneration patterns of ANFs across the cochlea.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] What can stimulus polarity and interphase gap tell us about auditory nerve function in cochlear-implant recipients?
    Hughes, Michelle L.
    Choi, Sangsook
    Glickman, Erin
    HEARING RESEARCH, 2018, 359 : 50 - 63
  • [42] Responses of Auditory Nerve and Anteroventral Cochlear Nucleus Fibers to Broadband and Narrowband Noise: Implications for the Sensitivity to Interaural Delays
    van der Heijden, Marcel
    Louage, Dries H. G.
    Joris, Philip X.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2011, 12 (04): : 485 - 502
  • [43] Responses of Auditory Nerve and Anteroventral Cochlear Nucleus Fibers to Broadband and Narrowband Noise: Implications for the Sensitivity to Interaural Delays
    Marcel van der Heijden
    Dries H. G. Louage
    Philip X. Joris
    Journal of the Association for Research in Otolaryngology, 2011, 12
  • [44] A real-time implementation of cochlear implant stimulation strategy based on wavelet transform
    Derbel, Amira
    Ghorbel, Mohamed
    Samet, Mounir
    Ben Hamida, Ahmed
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 10 (03) : 275 - 295
  • [45] Investigation of Electrically Evoked Auditory Brainstem Responses to Multi-Pulse Stimulation of High Frequency in Cochlear Implant Users
    Saeedi, Ali
    Hemmert, Werner
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [46] Examining the Auditory Nerve Fiber Response to High Rate Cochlear Implant Stimulation: Chronic Sensorineural Hearing Loss and Facilitation
    Heffer, Leon F.
    Sly, David J.
    Fallon, James B.
    White, Mark W.
    Shepherd, Robert K.
    O'Leary, Stephen J.
    JOURNAL OF NEUROPHYSIOLOGY, 2010, 104 (06) : 3124 - 3135
  • [47] Sensitivity and reliability of fNIRS to detect cochlear implant-induced auditory cortical activation in prelingually deaf children with inner ear malformation or cochlear nerve deficiency
    Yamazaki, Hiroshi
    Moroto, Saburo
    Yamazaki, Tomoko
    Tamaya, Rinko
    Fujii, Naoko
    Fujiwara, Keizo
    Naito, Yasushi
    BRAIN RESEARCH, 2025, 1856
  • [48] Analysis of a purely conductance-based stochastic nerve fibre model as applied to compound models of populations of human auditory nerve fibres used in cochlear implant simulations
    Werner Badenhorst
    Tania Hanekom
    Johan J. Hanekom
    Biological Cybernetics, 2017, 111 : 439 - 458
  • [49] CHANGES IN COCHLEAR SENSITIVITY DO NOT ALTER RELATIVE THRESHOLDS OF DIFFERENT SPONTANEOUS RATE CATEGORIES OF PRIMARY AUDITORY-NERVE FIBERS
    ROBERTSON, D
    WILSON, SA
    HEARING RESEARCH, 1991, 51 (01) : 29 - 32
  • [50] Analysis of a purely conductance-based stochastic nerve fibre model as applied to compound models of populations of human auditory nerve fibres used in cochlear implant simulations
    Badenhorst, Werner
    Hanekom, Tania
    Hanekom, Johan J.
    BIOLOGICAL CYBERNETICS, 2017, 111 (5-6) : 439 - 458