Comparison of Humeral Intramedullary Nail Internal Locking System and Standard External Locking System

被引:0
|
作者
Baris, Alican [1 ]
Ozturkmen, Yusuf [1 ]
机构
[1] Univ Hlth Sci Turkey, Istanbul Training & Res Hosp, Clin Orthoped & Traumatol, Istanbul, Turkey
来源
ISTANBUL MEDICAL JOURNAL | 2021年 / 22卷 / 04期
关键词
Humerus diaphysis fractures; humerus intramedullary nailing; distal locking; COMPRESSION PLATE; SHAFT FRACTURES;
D O I
10.4274/imj.galenos.2021.04695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study aimed to compare the 'Freehand Distal Locking (FHDL)" method, which is a standard in the distal locking stage of the humerus intramedullary nails, and the "Inside-to-Out Distal Locking (IODL)" Method, which was developed as a new nailing model. Methods: A total of 51 patients who underwent intramedullary nailing surgery due to humeral shaft fractures in our clinic were included in the study. Trigen Humeral nail (Smith and Nephew, Memphis, USA) with FHDL was used in 24 patients, and InSafeLock Humeral nail (TST, Istanbul, Turkey) with IODL in 27 patients. The effects of these two different nailing and locking techniques used in humeral shaft fractures in terms of surgical duration, radiation exposure duration, and functional/ radiological results were evaluated. Results: The mean follow-up period of the 51 patients (28 males and 23 females; mean age: 41.8 years) was 34.6 months (range: 9-76). According to the AO classification, 24 fractures were evaluated as type A, 17 were type B, and 10 were type C. The general evaluation of all cases revealed positive correlations between the surgical and radiation exposure durations (r=0.855; p<0.01). As the surgery duration prolonged, the ionizing radiation exposure increased. The comparison of the two groups determined a decreased surgical duration by 24.9 minute (81.6 min vs 106.5 min) and a decreased radiation exposure duration by 28.8 sec (17.7 sec vs 41.5 sec) in the IODL case group compared to the FHDL case group (p<0.05). The functional result evaluation revealed constant scorings that were satisfactory and close to each other in both groups (94.3 vs 93.3) (p>0.05). The full union was obtained in all patients except one case in the FHDL group. Symptomatic biceps tendinopathy findings were detected in four cases in the IODL group and five in the FHDL group. Local pain and sensitivity were detected in two cases in the IODL group in the form of impingement in the triceps olecranon insertion, where the distal end of the endopin is located. Conclusion: Distal locking is the most problematic stage of humerus nailing surgeries. Adjustable external guides solve the proximal locking problem; however, they are insufficient in distal locking. Therefore, the FHDL method is more preferred in distal locking, which causes problems like prolonged surgical durations and excessive ionizing radiation exposure. The surgical duration shortened and ionizing radiation exposure decreased at significant levels in the IODL humerus nailing with endopin. In addition, the lack of additional incisions for distal locking will avoid possible neurovascular injuries and incision-related wound complications.
引用
收藏
页码:250 / 256
页数:7
相关论文
共 50 条
  • [31] Use of an Intramedullary Locking Nail for the Treatment of Patella Fractures
    Ladenburger, P-P
    Ladenburger, A.
    Moghaddam, A.
    Raven, T. F.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2021, 88 (04) : 260 - 265
  • [32] Arthroscopic tibiotalocalcaneal arthrodesis using an intramedullary locking nail
    Baumbach, Sebastian Felix
    Massen, Felix
    Boecker, Wolfgang
    Polzer, Hans
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2020, 32 (02): : 158 - 170
  • [33] Nail over nail technique for distal locking of femoral intramedullary nails
    Rohilla, Rajesh
    Singh, Roop
    Magu, Narender
    Devgun, Ashish
    Siwach, Ramchander
    Gulia, Ashish
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1107 - 1112
  • [34] INTRAMEDULLARY LOCKING FEMORAL NAILS - EXPERIENCE WITH THE AO NAIL
    FOGARTY, AB
    YEATES, HA
    ULSTER MEDICAL JOURNAL, 1991, 60 (02): : 129 - 136
  • [35] Nail over nail technique for distal locking of femoral intramedullary nails
    Rajesh Rohilla
    Roop Singh
    Narender Magu
    Ashish Devgun
    Ramchander Siwach
    Ashish Gulia
    International Orthopaedics, 2009, 33
  • [36] Distal femoral fixation: A biomechanical comparison of retrograde nail, retrograde intramedullary nail, and prototype locking retrograde nail
    Heiney, Jake P.
    Battula, Suneel
    O'Connor, Jill A.
    Ebraheim, Nabil
    Schoenfeld, Andrew J.
    Vrabec, Gregory
    CLINICAL BIOMECHANICS, 2012, 27 (07) : 692 - 696
  • [37] Nail Versus Plate: A Biomechanical Comparison of a Locking Plate Versus an Intramedullary Nail With an Angular Stable Locking System in a Shoulder Simulator With Active Muscle Forces Using a Two-Part Fracture Model
    Strasser, Susanne
    Kralinger, Franz
    Blauth, Michael
    Schmoelz, Werner
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (03) : E71 - E76
  • [38] INTRAMEDULLAR-LOCKING-NAIL-SYSTEM - STABLE AIMING-DEVICE FOR DISTAL LOCKING
    SOYKA, P
    BUSSARD, C
    HELVETICA CHIRURGICA ACTA, 1990, 57 (01) : 117 - 120
  • [39] Treatment of pathological fractures of the humeral shaft due to bone metastases: A comparison of intramedullary locking nail and plate osteosynthesis with adjunctive bone cement
    Dijkstra, S
    Stapert, J
    Boxma, H
    Wiggers, T
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1996, 22 (06): : 621 - 626
  • [40] Biomechanical comparison of tuberosity-based proximal humeral locking plate compared to standard proximal humeral locking plate in varus cantilever bending
    Saunders, Patrick E.
    Castaneda, Paulo
    Walker, Robert
    McKee, Michael D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (11): : 3650 - 3654