Use of a miniature diamond-anvil cell in high-pressure single-crystal neutron Laue diffraction

被引:23
|
作者
Binns, Jack [1 ,2 ,3 ]
Kamenev, Konstantin V. [4 ,5 ]
McIntyre, Garry J. [1 ]
Moggach, Stephen A. [2 ,3 ]
Parsons, Simon [2 ,3 ]
机构
[1] Australian Nucl Sci & Technol Org, New Illawarra Rd, Lucas Heights, NSW 2234, Australia
[2] Univ Edinburgh, BEaStCHEM Sch Chem, Kings Bldg,West Mains Rd, Edinburgh EH9 3FJ, Midlothian, Scotland
[3] Univ Edinburgh, Ctr Sci Extreme Condit, Kings Bldg,West Mains Rd, Edinburgh EH9 3FJ, Midlothian, Scotland
[4] Univ Edinburgh, Sch Engn, Erskine Williamson Bldg,Kings Bldg, Edinburgh EH9 3JJ, Midlothian, Scotland
[5] Univ Edinburgh, Ctr Sci Extreme Condit, Erskine Williamson Bldg,Kings Bldg, Edinburgh EH9 3JJ, Midlothian, Scotland
来源
IUCRJ | 2016年 / 3卷
基金
英国工程与自然科学研究理事会;
关键词
high pressure; neutron diffraction; Laue diffraction; L-ARGININE DIHYDRATE; X-RAY-DIFFRACTION; THERMAL PARAMETERS; POWDER DIFFRACTION; GPA; HEXAMETHYLENETETRAMINE; REFLECTIONS; ICE; TEMPERATURE; INTEGRATION;
D O I
10.1107/S2052252516000725
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The first high-pressure neutron diffraction study in a miniature diamond-anvil cell of a single crystal of size typical for X-ray diffraction is reported. This is made possible by modern Laue diffraction using a large solid-angle image-plate detector. An unexpected finding is that even reflections whose diffracted beams pass through the cell body are reliably observed, albeit with some attenuation. The cell body does limit the range of usable incident angles, but the crystallographic completeness for a high-symmetry unit cell is only slightly less than for a data collection without the cell. Data collections for two sizes of hexamine single crystals, with and without the pressure cell, and at 300 and 150 K, show that sample size and temperature are the most important factors that influence data quality. Despite the smaller crystal size and dominant parasitic scattering from the diamond-anvil cell, the data collected allow a full anisotropic refinement of hexamine with bond lengths and angles that agree with literature data within experimental error. This technique is shown to be suitable for low-symmetry crystals, and in these cases the transmission of diffracted beams through the cell body results in much higher completeness values than are possible with X-rays. The way is now open for joint X-ray and neutron studies on the same sample under identical conditions.
引用
收藏
页码:168 / 179
页数:12
相关论文
共 50 条
  • [31] HIGH-PRESSURE MOSSBAUER-SPECTROSCOPY USING A DIAMOND-ANVIL CELL
    NASU, S
    HYPERFINE INTERACTIONS, 1994, 90 (1-4): : 59 - 75
  • [32] WEDGE-DRIVEN AND MINIATURE DIAMOND-ANVIL CELLS FOR HIGH-PRESSURE OPTICAL AND X-RAY-DIFFRACTION STUDIES
    AOKI, K
    KAKUDATE, Y
    YOSHIDA, M
    USUBA, S
    TANAKA, K
    FUJIWARA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (12): : 2107 - 2110
  • [33] SIMPLE IMPROVEMENTS TO A DIAMOND-ANVIL HIGH-PRESSURE CELL FOR X-RAY DIFFRACTION STUDIES.
    Skelton, Earl F.
    Liu, Cheng-yin
    Spain, Ian L.
    High Temperatures - High Pressures, 1977, 9 (01) : 19 - 26
  • [34] Diamond-anvil cell for single-crystal x-ray diffraction studies to pressures in excess of 10 GPa
    Allan, DR
    Miletich, R
    Angel, RJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 840 - 842
  • [35] Diamond-anvil cell for single-crystal x-ray diffraction studies to pressures in excess of 10 GPa
    Allan, D.R.
    Miletich, R.
    Angel, R.J.
    Review of Scientific Instruments, 1996, 67 (3 pt 1): : 840 - 842
  • [36] IMPROVED DIAMOND ANVIL HIGH-PRESSURE-CELL FOR SINGLE-CRYSTAL WORK
    KOEPKE, J
    DIETERICH, W
    GLINNEMANN, J
    SCHULZ, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (11): : 2119 - 2122
  • [37] HIGH-PRESSURE CRYSTAL-STRUCTURE STUDIES ON NITROGEN AND OTHER CRYOGENIC GASES IN A DIAMOND-ANVIL CELL
    SCHIFER, D
    CROMER, DT
    MILLS, RL
    LIEBENBERG, DH
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S343 - S343
  • [38] HIGH-PRESSURE DIAMOND-ANVIL CELL FOR MEASURING RESISTANCE AT LOW-TEMPERATURES
    KUZEMSKAYA, IG
    TIMOFEEV, YA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1993, 36 (04) : 649 - 650
  • [39] WEDGE-DRIVEN AND MINIATURE DIAMOND-ANVIL CELLS FOR HIGH-PRESSURE OPTICAL AND X-RAY DIFFRACTION STUDIES.
    Aoki, Katsutoshi
    Kakudate, Yozo
    Yoshida, Masatake
    Usuba, Shu
    Tanaka, Katsumi
    Fujiwara, Syuzo
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes, 1987, 26 (12): : 2107 - 2110
  • [40] Hydrogen bonding and dynamics of methanol by high-pressure diamond-anvil cell NMR
    Okuchi, T
    Cody, GD
    Mao, HK
    Hemley, RJ
    JOURNAL OF CHEMICAL PHYSICS, 2005, 122 (24):