High-pressure xenon (HPXe) gas is a desirable radiation detection medium for homeland security applications because of its good inherent room-temperature energy resolution, potential for large, efficient devices, and stability over a broad temperature range. Past work in HPXe has produced large-diameter gridded ionization chambers with energy resolution at 662 keV between 3.5 and 4% FWHM. However, one major limitation of these detectors is resolution degradation due to Frisch grid microphonics. Improved energy resolution using a detector with coplanar anodes as an alternative to a Frisch grid is reported in this submission. It is expected that a coplanar anode design has the potential to provide competitive energy resolution with minimal degradation from microphonics. Experimental data is presented, including an analysis of interaction location effects on the energy spectrum. The HPXe gas is doped with a small amount of H-2 gas to improve charge transport, and the results are compared with Geant simulations.
引用
收藏
页码:1048 / 1051
页数:4
相关论文
共 50 条
  • [41] High-resolution spectroscopy of gamma-ray bursts with the transient gamma-ray spectrometer
    Kurczynski, P
    Palmer, D
    Seifert, H
    Teegarden, BJ
    Gehrels, N
    Cline, TL
    Ramaty, R
    Hurley, K
    Madden, NW
    Pehl, RH
    ASTROPHYSICAL JOURNAL, 2000, 543 (01): : 77 - 89
  • [42] HIGH-PRESSURE REACTIONS .2. GAMMA-RAY POLYMERIZATION OF ACRYLAMIDE
    PRINCE, M
    HORNYAK, J
    JOURNAL OF POLYMER SCIENCE PART A-1-POLYMER CHEMISTRY, 1967, 5 (3PA1): : 531 - &
  • [43] Identification of hidden fissile materials using high pressure xenon gamma-ray detectors
    Ulin, SE
    Dmitrenko, VV
    Grachev, VM
    Sokolov, DV
    Uteshev, ZM
    Chemysheva, IV
    Vlasik, KF
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 : 221 - 225
  • [44] Performance of CdZnTe coplanar-grid gamma-ray detectors
    Luke, PN
    Eissler, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1481 - 1486
  • [45] Measurement of Radon concentration by Xenon gamma-ray spectrometer for seismic monitoring of the Earth
    Novikov, A.
    Ulin, S.
    Dmitrenko, V.
    Vlasik, K.
    Bychkova, O.
    Petrenko, D.
    Uteshev, Z.
    Shustov, A.
    INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2015), PTS 1-4, 2016, 675
  • [46] The impact of multiple-site interactions on the energy resolution of a high-pressure xenon γ-ray spectrometer
    Kiff, Scott D.
    He, Zhong
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1062 - 1068
  • [47] THE SMM GAMMA-RAY SPECTROMETER - INITIAL PERFORMANCE AND CALIBRATION
    FORREST, DJ
    CHUPP, EL
    RYAN, JM
    CHERRY, ML
    REPPIN, C
    RIEGER, E
    PINKAU, K
    KANBACH, G
    SHARE, G
    KINZER, RL
    KURFESS, JD
    JOHNSON, WN
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (04): : 597 - 597
  • [48] HIGH-FLUX GAMMA-RAY COMPTON SPECTROMETER
    ROLLASON, AJ
    SCHNEIDER, JR
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1987, 178 (1-4): : 189 - 189
  • [49] Gamma-Ray Spectrometer with High Event Processing Rate
    Ivanova, A. A.
    Ivanenko, S. V.
    Kvashnin, A. N.
    Puriga, E. A.
    Rovenskikh, A. F.
    Khilchenko, A. D.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1052 - 1055
  • [50] DETERMINATION OF GAMMA-RAY POSITION USING A HIGH-PRESSURE FLASH TUBE CHAMBER
    BREARE, JM
    DOE, PJ
    ELDISOUKI, W
    NANDI, BC
    TAIT, ID
    NUCLEAR INSTRUMENTS & METHODS, 1977, 143 (01): : 49 - 55