Reducing Patient Radiation Dose during CT-Guided Procedures: Demonstration in Spinal Injections for Pain

被引:37
|
作者
Shepherd, T. M. [1 ]
Hess, C. P. [1 ]
Chin, C. T. [1 ]
Gould, R. [1 ]
Dillon, W. P. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Neuroradiol Div, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY; OPTIMIZATION;
D O I
10.3174/ajnr.A2634
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: CT guidance may improve precision for diagnostic and therapeutic spinal injections, but it can increase patient radiation dose. This study examined the impact of reducing tube current on patient radiation exposure and the technical success for these procedures, by using axial acquisitions for short scan lengths and eliminating nonessential imaging. MATERIALS AND METHODS: Our institutional review board approved retrospective analysis of records from 100 consecutive outpatients undergoing spinal injections for pain before and after the CT protocol modification to reduce radiation dose. Data collected included patient age and sex, response to injection, number of sites and spinal levels treated, injection type, performing physician, CT acquisition method, number of imaging series, tube current, scan length, and DLP. RESULTS: Image contrast was reduced with the low-dose protocol, but this did not affect technical success or immediate pain relief. Mean DLP for all procedures decreased from 1458 +/- 1022 to 199 +/- 101 mGy . cm (P < .001). The range of radiologist-dependent DLP per procedure also was reduced significantly with the modified protocol. Selective nerve root blocks, lumbar injections, multiple injection sites, and the lack of prior imaging were each associated with a slightly higher DLP (<50 mGy . cm). CONCLUSIONS: Radiation to patients undergoing CT-guided spinal injections can be decreased significantly without affecting outcome by reducing tube current, using axial acquisitions for short scan lengths, and eliminating nonessential imaging guidance. These measures also decrease variability in radiation doses between different practitioners and should be useful for other CT-guided procedures in radiology.
引用
收藏
页码:1776 / 1782
页数:7
相关论文
共 50 条
  • [31] CT-guided interventional procedures for pain management in the lumbosacral spine
    Gangi, A
    Dietemann, JL
    Mortazavi, R
    Pfleger, D
    Kauff, C
    Roy, C
    RADIOGRAPHICS, 1998, 18 (03) : 621 - 633
  • [32] A simple training tool for CT-guided spinal pain management
    Gossner, Johannes
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (04) : 381 - 383
  • [33] The Safety of CT-Guided Epidural Steroid Injections in an Older Patient Cohort
    Fenster, Andrew J.
    Fernandes, Kevin
    Brook, Alan L.
    Miller, Todd S.
    PAIN PHYSICIAN, 2016, 19 (08) : E1139 - E1146
  • [34] Radiation Dose Reduction for CT-Guided Renal Tumor Cryoablation
    Leng, Shuai
    Atwell, Thomas D.
    Yu, Lifeng
    Mandrekar, Jay
    Lewis, Bradley D.
    Woodrum, David A.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : W586 - W591
  • [35] CT-Guided intervention with low radiation dose: Feasibility and experience
    Lucey, Brian C.
    Varghese, Jose C.
    Hochberg, Aaron
    Blake, Michael A.
    Soto, Jorge A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1187 - 1194
  • [36] Potential Clinical Ramifications of Dose Alert on CT-Guided Interventional Procedures
    McCollough, Cynthia H.
    Favazza, Christopher P.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (05) : 542 - 544
  • [37] CT-guided interventional pain-therapy: Experience in 202 procedures
    Maas, R
    Krupski, G
    Weber, C
    Kroeger, S
    Beck, H
    Buecheler, E
    RADIOLOGY, 1997, 205 : 22 - 22
  • [38] Radiation dose during CT-guided percutaneous cryoablation of renal tumors: Effect of a dose reduction protocol
    Levesque, Vincent M.
    Shyn, Paul B.
    Tuncali, Kemal
    Tatli, Servet
    Nawfel, Richard D.
    Olubiyi, Olutayo
    Silverman, Stuart G.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2218 - 2221
  • [39] Radiation dose reduction in CT-guided cryoablation of renal tumors
    Zhong, Jim
    Gallagher, Michael
    Hounslow, Chris
    Iball, Gareth
    Wah, Tze
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (02) : 244 - 248
  • [40] Radiation Dose Reduction for CT-guided Renal Tumor Cryoablation
    Leng, S.
    Atwell, T.
    Yu, L.
    Mandrekar, J.
    Liewis, B.
    Woodrum, D.
    Bruesewitz, M.
    McCollough, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)