Geant4 Simulation for Commissioning of Proton Therapy Centre

被引:1
|
作者
Tan, Hong Qi [1 ]
Phua, Jun Hao [2 ]
Tan, Lloyd [2 ]
Ang, Khong Wei [2 ]
Lee, James [2 ]
Bettiol, Andrew Anthony [1 ]
机构
[1] Natl Univ Singapore, Dept Phys, Ctr Ion Beam Applicat, Singapore, Singapore
[2] Natl Canc Ctr Singapore, Singapore, Singapore
关键词
Proton therapy; Monte Carlo; Beamline simulation;
D O I
10.1007/978-981-10-9035-6_108
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In anticipation of the new Proton Therapy Centre in Singapore at 2020, the medical physicists and physicists in NCCS and NUS have come together to do several preparation/preliminary works. Of which, one of the most important programme is to develop the Monte Carlo simulation capability using GEANT4 toolkit. We simulated the entire beam delivery and nozzle based on specifications given by Hitachi. The results of the Energy-Range curves in water phantom together with spot size in air agrees well with measurement data provided by Hitachi. We will show the complete methodology of simulation leading up to the comparison with measurement data. There were 3 main aspects we focused on-(1) The choice of physics models, (2) The determination of initial proton phase space based on Twiss parameters from beam profile measurement and (3) The choice of cut-off energy and step size. This simulation is important for the commissioning of the Proton Therapy System and the methodology presented will be helpful for other upcoming centers who are interested in doing the same.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 50 条
  • [21] GEANT4 simulation in proton medical imaging: A transport models comparison
    Silva, R. C. L.
    Denyak, V.
    Hoff, G.
    Paschuk, S. A.
    Schelin, H. R.
    Setti, J. A. P.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172
  • [22] GEANT4 based simulation framework for particle therapy system
    Aso, Tsukasa
    Kimura, Akinori
    Kameoka, Satoru
    Murakami, Kouichi
    Sasaki, Takashi
    Yamashita, Tomohiro
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2564 - +
  • [23] Modeling Considerations for Improving Accuracy of a Proton Therapy Beam with GEANT4
    Barnes, Samuel R. S.
    McAuley, Grant A.
    Slater, James M.
    Wroe, Andrew J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2107 - 2112
  • [24] Pencil Beam Algorithm on the GEANT4 Based Simulation Framework and Verification of the Dose Distributions for Proton Therapy
    Aso, Tsukasa
    Yamashita, Tomohiro
    Akagi, Takashi
    Sasaki, Takashi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2166 - +
  • [25] Simulation of the RIBRAS Facility with GEANT4
    L. E. Tamayose
    J. C. Zamora
    G. F. Fortino
    D. Flechas
    Brazilian Journal of Physics, 2022, 52
  • [26] Geant4 simulation of the ABALONE photosensor
    Pieramico, G.
    Biondi, R.
    D'andrea, V
    Ferella, A. D.
    Mahlstedt, J.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2022, 45 (01):
  • [27] GEANT4 as a simulation framework in μSR
    Shiroka, T.
    Prokscha, T.
    Morenzoni, E.
    Sedlak, K.
    PHYSICA B-CONDENSED MATTER, 2009, 404 (5-7) : 966 - 969
  • [28] Hadronic shower simulation with GEANT4
    Wellisch, HP
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 522 - 529
  • [29] Simulation of dark bremsstrahlung in GEANT4
    Eichlersmith, Tom
    Mans, Jeremiah
    Moreno, Omar
    Muse, Joseph
    Revering, Michael
    Toro, Natalia
    COMPUTER PHYSICS COMMUNICATIONS, 2023, 287
  • [30] Electron backscattering simulation in Geant4
    Dondero, Paolo
    Mantero, Alfonso
    Ivanchencko, Vladimir
    Lotti, Simone
    Mineo, Teresa
    Fioretti, Valentina
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2018, 425 : 18 - 25