Investigation on Noise Pollution Comprehensive Treatment of Distribution Transformer in Living Area

被引:1
|
作者
Li, Li [1 ]
Fan, Xiaopeng [1 ]
Wu, Kecheng [2 ]
Zou, Zhuanglei [1 ]
Zhou, Yongyan [1 ]
Zhang, Dianhai [3 ]
Ren, Ziyan [3 ]
Zhang, Yanli [3 ]
机构
[1] Guangdong Power Grid Ltd Liabil Corp, Elect Power Res Inst, Guangzhou 510082, Peoples R China
[2] Guangdong Power Grid Ltd Liabil Corp, Guangzhou 510082, Peoples R China
[3] Shenyang Univ Technol, Sch Elect Engn, Shenyang 110178, Peoples R China
来源
SOUND AND VIBRATION | 2019年 / 53卷 / 06期
关键词
Acoustical enclosure; distribution transformer; noise pollution; treatment; vibration isolation pad;
D O I
10.32604/sv.2019.05252
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the current paper, which deals with the noise pollution excited by distribution transformers in the living area, a comprehensive treatment scheme is put forward for the purpose of reducing the sound pressure level emitting into the environment. In accordance with the associated test standard, the sound pressure levels of distribution transformer and surrounding environment are not only tested but analyzed as well. The measurements were carried out with the frequency analysis of the 1/3 octave resolution, with the center frequencies at 125 Hz, 250 Hz, 400 Hz, and 500 Hz. As illustrated, on the basis of the measurement results, the frequency of noise at 500 Hz of distribution transformer causes the major noise pollution in the surrounding environment. This measurement result is in line with the noise frequency characteristics of distribution transformer. There are two transmission routes of noise: i) the noise excited by distribution transformer transmits by means of the wall of distribution room, and ii) part of noise spreads through the ground of distribution room. Accordingly, acoustic shield and vibration isolation device are applied for the reduction of the low frequency noise emitted through the above two paths. Aimed at applying the appropriate acoustic material and vibration mounting, the evaluation of the noise reduction and vibration absorption is carried out in accordance with the sound and vibration insulation theory. Following the noise treatment, the transformer and environment noise are measured again. The corresponding findings shed light on the fact that the sound level satisfied the requirement of limits of the ordinance. The proposed noise treatment scheme can be applied to the existing power distribution facilities for controlling the sound levels that reach a point where it is comparatively more unobjectionable.
引用
收藏
页码:251 / 262
页数:12
相关论文
共 50 条
  • [22] Investigation of overvoltage effects for commonly used distribution transformer
    Haider, Mohammad S.
    Vaziri, Mohammad
    Phillips, David
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 3069 - +
  • [23] A comprehensive review of noise pollution monitoring studies at bus transit terminals
    Kumari, Supriya
    Sharma, Anjali
    Ghosh, Ashok Kumar
    NOISE MAPPING, 2024, 11 (01)
  • [24] Experimental investigation of distribution transformer aged solid insulation
    Mousavi, MJ
    Butler-Purry, KL
    2002 45TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2002, : 192 - 195
  • [25] A comprehensive approach for investigation of prenatal exposure to ambient air pollution
    Klepac, P.
    Locatelli, I.
    Korosec, S.
    Kunzli, N.
    Kukec, A.
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2018, 28 : 432 - 433
  • [26] Investigation and comprehensive evaluation of the litter pollution on the Heishijiao beach in Dalian
    Han, Mengdi
    Zhao, Kaiyuan
    Zhang, Yan
    Sui, Chuanguo
    INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [27] Study on comprehensive evaluation of environmental pollution treatment effect in coal mine subsidence area: taking Xinglongzhuang mining area of Yanzhou energy as an example
    Guo, Pengyuan
    Sun, Fengqi
    Han, Xiuyan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (03) : 6132 - 6145
  • [28] Study on comprehensive evaluation of environmental pollution treatment effect in coal mine subsidence area: taking Xinglongzhuang mining area of Yanzhou energy as an example
    Pengyuan Guo
    Fengqi Sun
    Xiuyan Han
    Environmental Science and Pollution Research, 2023, 30 : 6132 - 6145
  • [29] Comprehensive Assessment of Pollution Sources and Health Impacts in Suburban Area of Shanghai
    Wei, Wan
    Wang, Meng
    Yuan, Qi
    Zhang, Zhuozhi
    Li, Xinwei
    Han, Shuwen
    Duan, Yusen
    Fu, Qingyan
    Lee, Shun-Cheng
    TOXICS, 2023, 11 (07)
  • [30] Transformer-based low frequency noise measurement system for the investigation of infrared detectors' noise
    Achtenberg, Krzysztof
    Mikolajczyk, Janusz
    Ciofi, Carmine
    Scandurra, Graziella
    Bielecki, Zbigniew
    MEASUREMENT, 2022, 190