Investigation on Noise Pollution Comprehensive Treatment of Distribution Transformer in Living Area

被引:1
|
作者
Li, Li [1 ]
Fan, Xiaopeng [1 ]
Wu, Kecheng [2 ]
Zou, Zhuanglei [1 ]
Zhou, Yongyan [1 ]
Zhang, Dianhai [3 ]
Ren, Ziyan [3 ]
Zhang, Yanli [3 ]
机构
[1] Guangdong Power Grid Ltd Liabil Corp, Elect Power Res Inst, Guangzhou 510082, Peoples R China
[2] Guangdong Power Grid Ltd Liabil Corp, Guangzhou 510082, Peoples R China
[3] Shenyang Univ Technol, Sch Elect Engn, Shenyang 110178, Peoples R China
来源
SOUND AND VIBRATION | 2019年 / 53卷 / 06期
关键词
Acoustical enclosure; distribution transformer; noise pollution; treatment; vibration isolation pad;
D O I
10.32604/sv.2019.05252
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the current paper, which deals with the noise pollution excited by distribution transformers in the living area, a comprehensive treatment scheme is put forward for the purpose of reducing the sound pressure level emitting into the environment. In accordance with the associated test standard, the sound pressure levels of distribution transformer and surrounding environment are not only tested but analyzed as well. The measurements were carried out with the frequency analysis of the 1/3 octave resolution, with the center frequencies at 125 Hz, 250 Hz, 400 Hz, and 500 Hz. As illustrated, on the basis of the measurement results, the frequency of noise at 500 Hz of distribution transformer causes the major noise pollution in the surrounding environment. This measurement result is in line with the noise frequency characteristics of distribution transformer. There are two transmission routes of noise: i) the noise excited by distribution transformer transmits by means of the wall of distribution room, and ii) part of noise spreads through the ground of distribution room. Accordingly, acoustic shield and vibration isolation device are applied for the reduction of the low frequency noise emitted through the above two paths. Aimed at applying the appropriate acoustic material and vibration mounting, the evaluation of the noise reduction and vibration absorption is carried out in accordance with the sound and vibration insulation theory. Following the noise treatment, the transformer and environment noise are measured again. The corresponding findings shed light on the fact that the sound level satisfied the requirement of limits of the ordinance. The proposed noise treatment scheme can be applied to the existing power distribution facilities for controlling the sound levels that reach a point where it is comparatively more unobjectionable.
引用
收藏
页码:251 / 262
页数:12
相关论文
共 50 条
  • [1] Investigation of noise pollution in an urban area
    Herişanu, Nicolae
    Bacria, Vasile
    Toader, Mihai
    Radovan, Smaranda Popa
    WSEAS Transactions on Systems, 2006, 5 (07): : 1648 - 1653
  • [2] RESEARCH OF RAILWAY NOISE POLLUTION AT THE LIVING AREA OF RAILWAY STATION IN KLAIPEDA CITY AND DESIGNING OF NOISE BARRIER
    Paozalyte, Ilona
    Grubliauskas, Raimondas
    Vaitiekunas, Petras
    ENVIRONMENTAL ENGINEERING, VOLS 1-3, 2011, : 233 - 239
  • [3] INDUCTION DISTRIBUTION AND TRANSFORMER NOISE
    不详
    ELETTROTECNICA, 1969, 56 (05): : 312 - &
  • [4] Noise and Vibration Analysis of a Distribution Transformer
    Marcsa, Daniel
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (12): : 172 - 175
  • [5] Noise and Vibration Analysis of a Distribution Transformer
    Marcsa, Daniel
    2019 APPLICATIONS OF ELECTROMAGNETICS IN MODERN ENGINEERING AND MEDICINE (PTZE), 2019, : 109 - 112
  • [6] Comprehensive evaluation method of transformer area state oriented to transformer area management and its application
    Ouyang, Sen
    Yang, Jiahao
    Geng, Hongjie
    Wu, Yusheng
    Chen, Xinhui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 187 - 192
  • [7] Kitchen's pollution noise investigation and study
    Jiang Xiao-hong
    Wang Chang-hui
    Proceedings of the 4th International Academic Conference on Environmental and Occupational Medicine, 2007, : 78 - 78
  • [8] Comprehensive power loss analysis for hybrid distribution transformer
    Sang, Zixia
    Zheng, Xu
    Lei, He
    Yan, Jiong
    Cai, Jie
    Fang, Rengcun
    AIP ADVANCES, 2024, 14 (11)
  • [9] INVESTIGATION OF THE RELATIONSHIP BETWEEN NOISE POLLUTION AND ANXIETY
    Sahmurova, Aida
    Kiyak, Mithat
    Budak, Murat Erdem
    IIOAB JOURNAL, 2018, 9 (03) : 6 - 10
  • [10] NOISE POLLUTION AND HEALTH IMPACT IN URBAN ARGES AREA
    Iosub, Ion
    Iosub, Silvia
    Grigorie, Victor
    Meghea, Aurelia
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2009, 8 (04): : 855 - 858