High Sensitive Voltammetric Levothyroxine Sodium Determination on Renewable Mercury Film Silver Based Electrode

被引:17
|
作者
Smajdor, Joanna [1 ]
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
Smajdor, Zbigniew [2 ]
机构
[1] AGH UST Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
[2] State Higher Vocat Sch Nowy Sacz, PL-33300 Nowy Sacz, Poland
关键词
ADSORPTIVE STRIPPING VOLTAMMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; CETYLTRIMETHYL AMMONIUM BROMIDE; CARBON-PASTE ELECTRODE; FREE-THYROXINE; CAPILLARY-ELECTROPHORESIS; TRIIODOTHYRONINE; CHEMILUMINESCENCE; IMMUNOASSAY; REDUCTION;
D O I
10.1149/2.1431607jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Levothyroxine sodium (LS, L-T-4) is a sodium salt of natural thyroid hormone thyroxine (T-4), commonly used in treatment of hypothyroidism. In this work a new voltammetric method of levothyroxine sodium (LS) determination using renewable mercury film electrode is presented. A linear voltammetric response was obtained for analyte in the concentration range from 0.025 . 10(-6) mol L-1 (1.99 . 10(-5) g L-1) to 4.0 . 10(-6) mol L-1 (3.19 . 10(-3) g L-1), with a detection limit of 1.8 . 10(-8) mol L-1 for preconcentration time of 30 s. Repeatability of method was determined as RSD % for levothyroxine sodium concentration of 0.2 . 10(-6) mol L-1 as 1.4% (n = 9). The proposed method was successfully applied and validated by studying the recovery of levothyroxine sodium in different pharmaceutical products. (C) 2016 The Electrochemical Society. All rights reserved.
引用
收藏
页码:H605 / H609
页数:5
相关论文
共 50 条
  • [41] VOLTAMMETRIC STUDY OF THE BEHAVIOR OF AMARANTH AT A MERCURY THIN-FILM ELECTRODE ON A SILVER SUBSTRATE
    MO, SC
    NA, JM
    MO, H
    QU, XH
    TALANTA, 1992, 39 (10) : 1255 - 1258
  • [42] Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead
    Jovanovski, V.
    Hrastnik, N. I.
    Hocevar, S. B.
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 57 : 1 - 4
  • [43] Copper–mercury film electrode for cathodic stripping voltammetric determination of Se(IV)
    Vladimir Sladkov
    François David
    Blandine Fourest
    Analytical and Bioanalytical Chemistry, 2003, 375 : 300 - 305
  • [44] VOLTAMMETRIC ELECTRODE WITH ELECTROCHEMICAL MERCURY FILM RENEWAL
    KHOSROEVA, DA
    TURYAN, YI
    STRIZHOV, NK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (07) : 948 - 951
  • [45] OPTIMIZATION OF METHOD FOR ZINC ANALYSIS IN SEVERAL BEE PRODUCTS ON RENEWABLE MERCURY FILM SILVER BASED ELECTRODE
    Opoka, Wlodzimerz
    Szlosarczyk, Marek
    Maslanka, Anna
    Piech, Robert
    Bas, Boguslaw
    Wlodarczyk, Edyta
    Krzek, Jan
    ACTA POLONIAE PHARMACEUTICA, 2013, 70 (06): : 961 - 965
  • [46] SILVER BASED MERCURY FILM ELECTRODE .4. COMPARISON OF THEORETICAL AND EXPERIMENTAL VOLTAMMETRIC RESULTS OBTAINED FOR CADMIUM
    OSTAPCZUK, P
    KUBLIK, Z
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1978, 93 (03) : 195 - 212
  • [47] Potentiometric determination of cysteine with thiol sensitive silver-mercury electrode
    Drozdz, Ryszard
    Naskalski, Jerzy
    Zabek-Adamska, Anna
    ACTA BIOCHIMICA POLONICA, 2007, 54 (01) : 205 - 211
  • [48] Electrochemical Study of Moroxydine and its Voltammetric Determination with a Silver Amalgam Film Electrode
    Skrzypek, S.
    ELECTROANALYSIS, 2011, 23 (12) : 2781 - 2788
  • [49] Voltammetric Determination of Folic Acid Using Liquid Mercury Free Silver Amalgam Electrode
    Bandzuchova, Lenka
    Selesovska, Renata
    ACTA CHIMICA SLOVENICA, 2011, 58 (04) : 776 - 784
  • [50] Renewable Silver-Amalgam Film Electrode for Rapid Square-Wave Voltammetric Determination of Thiamethoxam Insecticide in Selected Samples
    Putek, Maria
    Guzsvany, Valeria
    Tasic, Bojan
    Papp, Zsigmond
    Zarebski, Jerzy
    Bobrowski, Andrzej
    ELECTROANALYSIS, 2012, 24 (12) : 2258 - 2266