Experimental investigation of a novel multi-channel flat plate liquid desiccant dehumidification system

被引:7
|
作者
Sharma, Akash [1 ]
Kaushal, Rajneesh [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Kurukshetra 136119, Haryana, India
关键词
Liquid desiccant; dehumidification; regeneration; effectiveness; moisture absorption rates; AIR-CONDITIONING SYSTEM; NATURAL-GAS DEHYDRATION; MASS-TRANSFER; PERFORMANCE ANALYSIS; PARAMETRIC ANALYSIS; DEHUMIDIFIER/REGENERATOR; LITHIUM;
D O I
10.1080/15567036.2020.1789243
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The continuously growing energy demands for space air conditioning and depletion of conventional energy resources at a fast rate have propagated the need for producing a new and wide range of renewable and sustainable energy technologies. Liquid desiccant dehumidification technologies are the most optimistic approach due to their lower regeneration temperature required, a higher coefficient of performance, and the ability to be used during night hours. The factors responsible for the limited application of these systems are desiccant leakage, corrosion to the fabricating material, and carryover of desiccant droplets with the process air. To overcome these issues, a new multi-channel flat plate liquid desiccant air conditioning system has been developed and experimentally investigated. The performance of the system has been analyzed for the dehumidification and regeneration process. Calcium chloride has been used as a desiccant material with 40% and 35% by wt. concentration. Three sets of velocities of process air have been utilized, i.e., 0.9, 0.7, 0.5 m/s to investigate the system performance. Performance parameters, such as dehumidification rate, regeneration rate, dehumidification, and regeneration effectiveness, have been investigated in the present study. The liquid desiccant dehumidification system investigated in the present study includes a flat plate energy exchanger for heat and mass transfer between ambient moist air and liquid desiccant solution. This system conveys a large interfacial surface area between liquid desiccant solution and process air. Experimental results indicate that, in the dehumidification process, the ambient moist air has been dehumidified and cooled by 5.90 g kg(-1)and 1.4 degrees C, respectively, and dehumidification effectiveness of 0.239 has been achieved for the air velocity of 5 m/s at 40% concentration of the desiccant solution. Regeneration rate and effectiveness have been observed to be 0.014 g s(-1)and 0.323, respectively, for the air velocity of 5 m/s at 35% concentration. The work presented in this study demonstrates the feasibility of the novel multi-layer flat plat liquid desiccant concept and provide growth and development to the liquid desiccant technologies for space air conditioning. Certain issues regarding the mass imbalance in the dehumidification and regeneration processes have been identified to be considered as future scope.
引用
收藏
页码:11148 / 11166
页数:19
相关论文
共 50 条
  • [1] Experimental investigation of a liquid desiccant system for solar cooling and dehumidification
    Gommed, K.
    Grossman, G.
    SOLAR ENERGY, 2007, 81 (01) : 131 - 138
  • [2] Experimental and numerical investigation of a novel hybrid deep-dehumidification system using liquid desiccant
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    Ma, Zhiyao
    Chen, Liangliang
    Chen, Xiaoyang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 192 : 396 - 411
  • [3] AIR DEHUMIDIFICATION WITH NOVEL LIQUID DESICCANT SYSTEM
    Pantelic, J.
    Teitelbaum, E.
    Kim, S.
    Guo, H.
    Schlueter, A.
    Rysanek, A.
    Meggers, F.
    EXPANDING BOUNDARIES: SYSTEMS THINKING IN THE BUILT ENVIRONMENT, 2016, : 316 - 320
  • [4] Experimental investigation of a liquid desiccant system for air dehumidification working with ionic liquids
    Zegenhagen, Mark T.
    Ricart, Cristina
    Meyer, Thomas
    Kuehn, Roland
    Ziegler, Felix
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 544 - 551
  • [5] Experimental investigation of a liquid desiccant dehumidification system integrated with shallow geothermal energy
    Liang, Jyun-De
    Huang, Bo-Hao
    Chiang, Yuan-Ching
    Chen, Sih-Li
    ENERGY, 2020, 191
  • [6] EXPERIMENTAL ANALYSIS OF AIR DEHUMIDIFICATION SYSTEM WITH LIQUID DESICCANT
    Zhang, Li
    Chitose, Tanaka
    Hihara, Eiji
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, 2010, : 169 - 177
  • [7] Experimental investigation and model validation for liquid desiccant dehumidification and regeneration in falling-film plate
    Qian, Junfei
    Yin, Yonggao
    Pan, Xiongwei
    Zhang, Xiaosong
    Huagong Xuebao/CIESC Journal, 2014, 65 (06): : 2070 - 2077
  • [8] The design and experimental investigation of membrane-based tubular liquid desiccant dehumidification system
    Kavasogullari, Baris
    Cihan, Ertugrul
    Demir, Hasan
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2023, 29 (04): : 303 - 313
  • [9] PRELIMINARY INVESTIGATION OF A LIQUID DESICCANT SYSTEM FOR DEHUMIDIFICATION AND COOLING IN ATHENS
    Koronaki, I. P.
    Christodoulaki, R. I.
    Papaefthimiou, V. D.
    Rogdakis, E. D.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [10] Experimental investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Liu, Xiaohua
    Xie, Ying
    Zhang, Tao
    Chen, Liangliang
    Cong, Lin
    ENERGY AND BUILDINGS, 2018, 179 : 223 - 238