Ozonation combined with ultrasound for the degradation of tetracycline in a rectangular air-lift reactor

被引:87
|
作者
Wang, Yan [1 ]
Zhang, Hui [1 ]
Chen, Lu [1 ]
Wang, Sheng [1 ]
Zhang, Daobin [1 ]
机构
[1] Wuhan Univ, Dept Environm Engn, Wuhan 430079, Peoples R China
关键词
Ozone; Ultrasonic irradiation; Tetracycline; Rectangular air-lift reactor; Acute toxicity; LIQUID MASS-TRANSFER; AQUEOUS-SOLUTION; SONOLYTIC DECOMPOSITION; VETERINARY ANTIBIOTICS; OZONE; KINETICS; IRRADIATION; MECHANISM; WATER; COMBINATION;
D O I
10.1016/j.seppur.2011.06.035
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The application of ozonation has been limited by the poor mass transfer rate of ozone. In the presence of ultrasonic irradiation, mass transfer of ozone to the liquid phase could be enhanced and hydroxyl radicals may be generated by the decomposition of ozone in the gas phase. This study is to combine ozone with ultrasound (US/O-3) for the removal of tetracycline (TC). The effect of several operational parameters, including gaseous ozone concentration, gas flow rate, hydrogen peroxide concentration, hydroxyl radical scavenger, pH, initial TC concentration and power density on the removal of TC was investigated. The results showed that the TC removal followed pseudo-first-order kinetics. The IC removal rate increased with increasing gaseous ozone concentration, gas flow rate and power density, but decreased with increasing initial TC concentration. The presence of hydrogen peroxide improved the TC removal rate when the hydrogen peroxide concentration was not exceeded 10 mmol L-1. The presence of tert-butyl alcohol inhibited the TC removal rate to some extent. The main intermediates were identified and the degradation pathway of TC was proposed. After 90 min treatment, 91% COD was removed. The acute toxicity of the solution reached the maximum after 10 min treatment and then gradually decreased with the prolonging reaction time. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 50 条
  • [41] Air-lift internal loop biofilm reactor for realized simultaneous nitrification and denitrification
    Zhang, Cuiyi
    Wang, Lu
    Yan, Ning
    Zhang, Yongming
    Liu, Rui
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2013, 36 (05) : 597 - 602
  • [42] Production of poly(3-hydroxybutyrate) by Halomonas boliviensis in an air-lift reactor
    Rivera-Terceros, Paola
    Tito-Claros, Estefania
    Torrico, Sonia
    Carballo, Sergio
    Doan Van-Thuoc
    Quillaguaman, Jorge
    JOURNAL OF BIOLOGICAL RESEARCH-THESSALONIKI, 2015, 22
  • [43] CFD simulation of the hydrodynamics in an internal air-lift reactor with two different configurations
    Ebrahimifakhar M.
    Mohsenzadeh E.
    Moradi S.
    Moraveji M.
    Salimi M.
    Frontiers of Chemical Science and Engineering, 2011, 5 (4) : 455 - 462
  • [44] Air-lift internal loop biofilm reactor for realized simultaneous nitrification and denitrification
    Cuiyi Zhang
    Lu Wang
    Ning Yan
    Yongming Zhang
    Rui Liu
    Bioprocess and Biosystems Engineering, 2013, 36 : 597 - 602
  • [45] Pilot plant performance and model calibration of a sequencing batch air-lift reactor
    Brenner, A
    BenShushan, N
    Siegel, MH
    Merchuk, JC
    WATER SCIENCE AND TECHNOLOGY, 1997, 35 (01) : 121 - 128
  • [46] Numerical modelling of a three-phase internal air-lift circulating photocatalytic reactor
    Luo, Minghan
    Chen, Qiuwen
    Jeong, Taeseop
    Chen, Jing
    WATER SCIENCE AND TECHNOLOGY, 2017, 76 (11) : 3044 - 3053
  • [47] Bioleaching of marmatite flotation concentrate by adapted mixed mesoacidophilic cultures in an air-lift reactor
    Shi, SY
    Feng, ZH
    INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 2005, 76 (1-2) : 3 - 12
  • [48] Integrated treatments for metalworking effluent: chemistry precipitation and biotreatment in air-lift reactor type
    Queissada, Daniel Delgado
    da Silva, Flavio Teixeira
    Brazil de Paiva, Teresa Cristina
    ENGENHARIA SANITARIA E AMBIENTAL, 2011, 16 (02) : 181 - 188
  • [49] Mixing behavior of three-phase internal-loop air-lift reactor
    Cong, Wei
    Liu, Jianguo
    Ouyang, Fan
    Liao, Yonghong
    Huagong Yejin/Engineering Chemistry & Metallurgy, 2000, 21 (01): : 76 - 79
  • [50] Liquid/solid mass transfer in an air-lift loop reactor with a dispersed solid phase
    Wijffels, RH
    Verheul, M
    Beverloo, WA
    Tramper, J
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1998, 71 (02) : 147 - 154