A Graphene Oxide-DNA Electrochemical Sensor Based on Glassy Carbon Electrode for Sensitive Determination of Methotrexate

被引:33
|
作者
Chen, Jincheng [1 ]
Fu, Bo [1 ]
Liu, Tailin [1 ]
Yan, Zhihong [1 ]
Li, Kang [1 ]
机构
[1] Guangdong Pharmaceut Univ, Coll Pharm, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Methotrexate; DNA; Graphene oxide; Biological samples; ANTICANCER DRUG METHOTREXATE; BIMETALLIC NANOPARTICLES; VOLTAMMETRIC SENSOR; QUANTUM DOTS; NANOMATERIALS; HYBRIDIZATION; TRYPTOPHAN; BIOSENSOR; OXIDATION; TYROSINE;
D O I
10.1002/elan.201700615
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methotrexate (MTX) was used as an anti-cancer drug, but its excessive use can cause serious side effects, it was necessary to monitor MTX in vivo. In this report, DNA was immobilized on a glassy carbon electrode (GCE) modified with graphene oxide (GO) to develop an electrochemical sensor for sensitive determination of MTX for the first time. The adsorptive voltammetric behaviors of MTX on DNA sensor were investigated using differential pulse voltammetry (DPV). The peak current response of guanine in DNA was used as a determination signal of MTX in acetate buffer solution pH4.6. Voltammetric investigations revealed that the proposed method could determine MTX in the concentration range from 5.5x10(-8) to 2.2x10(-6)molL(-1) with a lower detection limit of 7.6x10(-)9molL(-1) (S/N=3). The method was applied to detect MTX in human blood serum and diluted urine samples with excellent recoveries of 97.4-102.5%. Compared with the previous studies, the DNA/GO/GCE electrode constructed by us based on the change rate of guanine current (R%) in DNA, proportionally reflecting the MTX concentration, is simple and sensitive.
引用
收藏
页码:288 / 295
页数:8
相关论文
共 50 条
  • [31] A sensitive DNA biosensor fabricated from gold nanoparticles and graphene oxide on a glassy carbon electrode
    Hajihosseini, Saeedeh
    Nasirizadeh, Navid
    Hejazi, Mohammad Saeid
    Yaghmaei, Parichereh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 : 506 - 515
  • [32] Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites
    Cui, Fei
    Zhang, Xiaoli
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 669 : 35 - 41
  • [33] Highly sensitive electrochemical sensor for tulobuterol detection based on facile graphene/Au nanowires modified glassy carbon electrode
    Huang, Huayu
    Nie, Rong
    Song, Yanyan
    Ji, Yongsheng
    Guo, Rui
    Liu, Zhihua
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 : 422 - 426
  • [34] Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes
    Junhua Li
    Daizhi Kuang
    Yonglan Feng
    Fuxing Zhang
    Zhifeng Xu
    Mengqin Liu
    Deping Wang
    Microchimica Acta, 2013, 180 : 49 - 58
  • [35] Electrochemical tyrosine sensor based on a glassy carbon electrode modified with a nanohybrid made from graphene oxide and multiwalled carbon nanotubes
    Li, Junhua
    Kuang, Daizhi
    Feng, Yonglan
    Zhang, Fuxing
    Xu, Zhifeng
    Liu, Mengqin
    Wang, Deping
    MICROCHIMICA ACTA, 2013, 180 (1-2) : 49 - 58
  • [36] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144
  • [37] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200
  • [39] A bimetallic nanoparticle/graphene oxide/thionine composite-modified glassy carbon electrode used as a facile ratiometric electrochemical sensor for sensitive uric acid determination
    Gao, Xiaohui
    Gui, Rijun
    Xu, Kendrick Qizhou
    Guo, Huijun
    Jin, Hui
    Wang, Zonghua
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (18) : 14796 - 14804
  • [40] A sensitive sensor based on molecularly imprinted polypyrrole on reduced graphene oxide modified glassy carbon electrode for nevirapine analysis
    Hassan Pour, Bayazid
    Haghnazari, Nahid
    Keshavarzi, Fatemeh
    Ahmadi, Elahe
    Zarif, Bahareh Rahimian
    ANALYTICAL METHODS, 2021, 13 (40) : 4767 - 4777