Near-infrared Fourier transform room-temperature photoluminescence of erbium complexes

被引:9
|
作者
Barbillat, J
Le Barny, P
Divay, L
Lallier, E
Grisard, A
Van Deun, R
Fias, P
机构
[1] USTL, CNRS, LASIR, F-59655 Villeneuve Dascq, France
[2] Thales Res & Technol France, F-91404 Orsay, France
[3] Katholieke Univ Leuven, Dept Chem, Coordinat Chem Div, B-3001 Louvain, Belgium
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 11期
关键词
D O I
10.1063/1.1614873
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A modified Fourier transform (FT) Raman bench spectrometer designed for the detection of weak light emission in the 800-1700 nm wavelength region has been used to demonstrate the advantages of FT spectroscopy for measuring near-infrared photoluminescence spectra of lanthanide complexes with a good resolution and very good sensitivity. This apparatus has been tested with an ultraviolet laser source (325 nm) on three standard erbium complexes. The I-4(13/2)-->I-4(15/2) emission of tris-(acetylacetonato) (1,10 phenanthroline) erbium [Er(acac)(3)(phen)], tris-(4,4,4,-trifluoro-1-(2 thenoyl)-1,3-butenedione) (1,10 phenanthroline) erbium [Er(TTFA)(3)(phen)] and tris(8-hydroxyquinolinato) erbium [Erq(3)] has thus been recorded in solution and in the solid state and compared with literature. (C) 2003 American Institute of Physics.
引用
收藏
页码:4954 / 4957
页数:4
相关论文
共 50 条
  • [21] Room-temperature photoluminescence of amorphous hydrogenated silicon carbide doped with erbium
    Terukov, EI
    Kudoyarova, VK
    Kuznetsov, AN
    Fuhs, W
    Weiser, G
    Kuehne, H
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 : 488 - 492
  • [22] FOURIER-TRANSFORM INFRARED-SPECTROSCOPY EVALUATION OF COMMERCIAL ROOM-TEMPERATURE VULCANIZED SILICONES
    RANGANATHAN, BN
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (19): : 2221 - 2226
  • [23] Strong near-infrared photoluminescence in erbium/ytterbium codoped porous silicon
    Luo, L
    Zhang, XX
    Li, KF
    Cheah, KW
    Gong, ML
    Shi, JX
    Wong, WK
    APPLIED PHYSICS LETTERS, 2005, 86 (21) : 1 - 3
  • [24] The Detection of Solidifying Point Temperature of TNT Using Fourier Transform Near-infrared Spectroscopy
    Gao J.
    She C.
    Chen J.
    Li M.
    Hou Y.
    Chen L.
    Wang J.
    Chen, Lizhen (Chen17555@163.com), 1600, China Ordnance Industry Corporation (41): : 1034 - 1040
  • [25] Room-temperature Near-infrared Excitonic Lasing from Mechanically Exfoliated InSe Microflake
    Li, Chun
    Zhao, Liyun
    Shang, Qiuyu
    Wang, Ruonan
    Bai, Peng
    Zhang, Jun
    Gao, Yunan
    Cao, Qiang
    Wei, Zhongming
    Zhang, Qing
    ACS NANO, 2022, 16 (01) : 1477 - 1485
  • [26] Near-infrared trace-gas sensors based on room-temperature diode lasers
    P. Werle
    R. Mücke
    F. D´Amato
    T. Lancia
    Applied Physics B, 1998, 67 : 307 - 315
  • [27] Room-temperature Near-infrared Electroluminescence in n-type GaAs Unipolar microLEDs
    Jacob, Bejoys
    Borme, Jerome
    Figueiredo, Jose M. L.
    Romeira, Bruno
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,
  • [28] Room-temperature near-infrared phosphorescence of a bismuthinidene N,C,N pincer complex
    Deuter, Katharina L.
    Balaba, Daisy J. J.
    Linseis, Michael
    Winter, Rainer F.
    CHEMICAL COMMUNICATIONS, 2025, 61 (17) : 3548 - 3551
  • [29] Near-infrared trace-gas sensors based on room-temperature diode lasers
    Werle, P
    Mucke, R
    D'Amato, F
    Lancia, T
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (03): : 307 - 315
  • [30] Determination of binding constants of cyclodextrins in room-temperature ionic liquids by near-infrared spectrometry
    Tran, CD
    Lacerda, SHD
    ANALYTICAL CHEMISTRY, 2002, 74 (20) : 5337 - 5341