Quantitative ultrasound parameters in ex-vivo fibrotic rabbit livers: Liver stiffness and tissue microstructure estimation

被引:0
|
作者
Escoffre, Jean-Michel [1 ]
Novell, Anthony [1 ]
Bouakaz, Ayache [1 ]
Benane, Yanis M. [2 ]
Basset, Olivier [2 ]
Franceschini, Emilie [3 ]
机构
[1] Univ Tours, Imagerie & Cerveau, INSERM, Tours, France
[2] Univ Lyon 1, CNRS, Creatis, Inserm,INSA, Lyon, France
[3] Aix Marseille Univ, CNRS, Cent Marseille, LMA, Marseille, France
关键词
STRUCTURE FACTOR MODEL; CELL PELLET BIOPHANTOMS; BACKSCATTER; ATTENUATION; HEPATITIS; FIBROSIS; DISEASE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Liver fibrosis is the common result of chronic liver disease. Diagnosis and grading liver fibrosis for patient management is mainly based on blood tests and hepatic puncture-biopsy, which is particularly invasive. Quantitative UltraSound (QUS) techniques provide insight into tissue microstructure and are based on the frequency-based analysis of the signals from biological tissues. This study aims to explore the diagnostic performance of QUS technique in high frequency (10-40 MHz) for detection of liver fibrosis. The changes in QUS parameters of healthy and fibrotic livers were investigated and were compared to the changes in liver stiffness using shear wave elastography (SWE). Liver fibrosis was induced by subcutaneous injection of CCI4 in the neck of rabbits. Attenuation and backscatter coefficients (BSCs) were estimated using the spectral difference method and the reference phantom method, respectively. Effective scatterer diameter (ESD) and effective acoustic concentration (EAC) were estimated by fitting the measured BSC to an estimated BSC calculated with a spherical Gaussian model. Finally, histopathological analysis of rabbit livers was performed using picrosirius red staining in order to rank the livers according to the Ishak fibrosis staging scale. Rabbit livers were classified on grade 0 (N=3), 2 (N=1), 3 (N=2), 4 (N=3) and 5 (N=2) using histological analysis. Mean attenuation at 40 MHz was higher in fibrotic livers: 0.83 dB/cm/MHz for grades 2 and 3, 0.90 dB/cm/MHz for grades 4 and 5, when compared to 0.59 dB/cm/MHz for healthy livers. Mean ESD estimated in the 10-20 MHz frequency bandwidth was observed to be 24 mu m, 31 mu m and 34 mu m for the healthy liver, for grades 2 and 3, and for grades 4 and 5, respectively. Results showed that the elastic (Young) modulus values were on the order of several thousand of Pascals. The elastic modulus generally increased with the fibrosis grade (scores 2 to 5).
引用
收藏
页数:4
相关论文
共 50 条
  • [21] LONG-TERM MAINTENANCE OF HUMAN LIVER TISSUE BY EX-VIVO PERFUSION OF LIVER SECTIONS
    Schreiter, T.
    Sowa, J. -P.
    Mathe, Z.
    Treckmann, J.
    Broecker-Preuss, M.
    Baba, H. A.
    Gieseler, R. K.
    Gerken, G.
    Canbay, A.
    JOURNAL OF HEPATOLOGY, 2014, 60 (01) : S70 - S70
  • [22] Quantitative Assessment of Thermal Lesion Stiffness in the Liver: Initial ex vivo Results
    Xie, Hua
    Zhou, Shiwei
    Shamdasani, Vijay
    Shi, Yan
    Robert, Jean-Luc
    Fraser, John
    Chen, Shigao
    Greenleaf, James F.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2098 - 2101
  • [23] A method for mimicking tumour tissue in brain ex-vivo ultrasound for research application and clinical training
    Weld, Alistair
    Dixon, Luke
    Anichini, Giulio
    Faoro, Giovanni
    Menciassi, Arianna
    Camp, Sophie
    Giannarou, Stamatia
    ACTA NEUROCHIRURGICA, 2025, 167 (01)
  • [24] Ultrasound Based Planning and Navigation for Non-Anatomical Liver Resections - An Ex-Vivo Study
    Paolucci, Iwan
    Sandu, Raluca-Maria
    Sahli, Luca
    Prevost, Gian Andrea
    Storni, Federico
    Candinas, Daniel
    Weber, Stefan
    Lachenmayer, Anja
    IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY, 2020, 1 : 3 - 8
  • [25] Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound
    Kang Il Lee
    Journal of the Korean Physical Society, 2018, 73 : 1289 - 1294
  • [26] Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound
    Lee, Kang Il
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (09) : 1289 - 1294
  • [27] IMPACT OF GRADED STEATOSIS ON THE EX-VIVO MACHINE PERFUSION PARAMETERS OF DONOR LIVERS USING A COMPREHENSIVE PROTOCOL OF PERFUSION TECHNIQUES
    Boteon, Yuri
    Laing, Richard
    Wallace, Lorraine
    Schlegel, Andrea
    Bhogal, Ricky
    Mirza, Darius
    Mergental, Hynek
    Afford, Simon
    TRANSPLANT INTERNATIONAL, 2017, 30 : 52 - 52
  • [28] Quantitative quasi-static ultrasound elastography using reference layer: Ex-vivo study.
    Selladurai, Sathiyamoorthy
    Thittai, Arun K.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 7107 - 7110
  • [29] Quantitative analysis of ultrasonographic images and cytology in relation to histopathology of canine and feline liver: An ex-vivo study
    Banzato, Tommaso
    Gelain, Maria Elena
    Aresu, Luca
    Centelleghe, Cinzia
    Benali, Silvia Lucia
    Zotti, Alessandro
    RESEARCH IN VETERINARY SCIENCE, 2015, 103 : 164 - 169
  • [30] Optical properties of normal and thermally coagulated chicken liver tissue measured ex-vivo with diffuse reflectance
    Hafeez-Ullah
    Atif, M.
    Firdous, S.
    Mehmood, M. S.
    Hamza, M. Y.
    Imran, M.
    Hussain, G.
    Ikram, M.
    OPTICS AND SPECTROSCOPY, 2011, 110 (02) : 313 - 319