Detection of HIV-1 antigen by quartz crystal microbalance using gold nanoparticles

被引:31
|
作者
Tan Nhiem Ly [1 ]
Park, Sangkwon [1 ]
Park, Sang Joon [2 ]
机构
[1] Dongguk Univ, Dept Chem & Biochem Engn, 30,Pildong Ro 1 Gil, Seoul 04620, South Korea
[2] Gachon Univ, Dept Chem & Biol Enhgineering, Songnam 461701, Gyeonggi, South Korea
来源
关键词
HIV-1; antigen; Quartz crystal microbalance; Gold nanoparticles; Early detection; Signal amplification; STREPTAVIDIN; PERFORMANCE;
D O I
10.1016/j.snb.2016.06.112
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the current exploratory study, a quartz crystal microbalance (QCM) technique was employed to detect HIV-1 antigen at a very low concentration using gold nanoparticles (Au NPs) as a signal enhancer. Colloidal Au NPs were synthesized using a reduction method followed by streptavidin functionalization. HIV-1 antigen was captured by a polyclonal antibody on the QCM surface that had been previously treated with 11-mercaptoundecanoicacid (MUA) and streptavidin. The Au NPs with a high mass amplified the detection signal, making HIV-1 antigen detection possible even in the window period of HIV infection. In addition, the effect of Au NP size was also investigated to elucidate the optimal size of the enhancer. The signal performance is discussed in terms of mass effect and conjugate efficiency. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:452 / 458
页数:7
相关论文
共 50 条
  • [21] STUDIES OF THE SURFACE ELECTROCHEMISTRY OF GOLD USING THE QUARTZ CRYSTAL MICROBALANCE TECHNIQUE
    BRUCKENSTEIN, S
    SHAY, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 132 - ANYL
  • [22] Improving the Sensitivity of a Quartz Crystal Microbalance for Biosensing by Using Porous Gold
    Danny van Noort
    Raffaele Rani
    Carl-Fredrik Mandenius
    Microchimica Acta, 2001, 136 : 49 - 53
  • [23] POLYSTYRENE NANOPARTICLES BASED IMMUNOASSAY FOR THE DETECTION OF beta-GALACTOSIDASE USING QUARTZ CRYSTAL MICROBALANCE
    Choudhary, M. K.
    Singh, Prashant
    Singh, K. P.
    NANO LIFE, 2013, 3 (01)
  • [24] Lubricity of gold nanocrystals on graphene measured using quartz crystal microbalance
    Lodge, M. S.
    Tang, C.
    Blue, B. T.
    Hubbard, W. A.
    Martini, A.
    Dawson, B. D.
    Ishigami, M.
    SCIENTIFIC REPORTS, 2016, 6
  • [25] Detection of β-caryophyllene in mango using a quartz crystal microbalance sensor
    Ali, Sk Babar
    Ghatak, Barnali
    Debabhuti, Nilava
    Sharma, Prolay
    Ghosh, Arunangshu
    Tudu, Bipan
    Bhattacharya, Nabarun
    Bandyopadhyay, Rajib
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 3064 - 3073
  • [26] Detection of Influenza Virus Subtype Using Quartz Crystal Microbalance
    Kagiyama, Shuichiro
    Masuda, Taisuke
    Kaihatsu, Kunihiro
    Kato, Nobuo
    Arai, Fumihito
    2014 INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE (MHS), 2014,
  • [27] Detection of sulfur dioxide using a piezoelectric quartz crystal microbalance
    Guimaraes, OM
    ANALYTICAL LETTERS, 1997, 30 (12) : 2159 - 2174
  • [28] Detection of CO2 using a quartz crystal microbalance
    Gomes, M.Teresa
    Duarte, Armando C.
    Oliveira, Joao P.
    Sensors and Actuators, B: Chemical, 1995, B26 (1 -3 pt 1): : 191 - 194
  • [29] Detection of Ebola glycoprotein using quartz crystal microbalance immunosensor
    Gerdon, Aren E.
    Huffman, Brian J.
    Wright, David W.
    Cliffel, David E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [30] Aptasensor for lead(II) based on the use of a quartz crystal microbalance modified with gold nanoparticles
    Min Yuan
    Zhihong Song
    Jiayu Fei
    Xinglong Wang
    Fei Xu
    Hui Cao
    Jinsong Yu
    Microchimica Acta, 2017, 184 : 1397 - 1403