Porous tantalum shell and augment for acetabular defect reconstruction in revision total hip arthroplasty: a mid-term follow-up study

被引:12
|
作者
Alqwbani, Mohammed [1 ]
Wang, Zhuoer [1 ,2 ]
Wang, Qiuru [1 ,2 ]
Li, Qianhao [1 ,2 ]
Yang, Zhouyuan [1 ,2 ]
Kang, Pengde [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthopaed, 37 Guoxue Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Radiol, Chengdu, Peoples R China
关键词
Acetabular defect; Porous tantalum shell; Augment; THA revision; COMPONENTS;
D O I
10.1007/s00264-022-05353-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim The use of porous tantalum trabecular metal (TM) shell and augment to reconstruct acetabular defects in revision total hip arthroplasty (THA) is a reliable technique. We evaluated the mid-term implant survival, clinical, and radiological outcomes of our first 48 revisions using this technique. Patients and methods A total of 45 patients (48 hips) who had acetabular revision of THA between 2011 and 2017 using TM shell and augment with possible mid-term follow-up were included. Twenty-two patients were men (49%) and 23 were women (51%), mean age was 62.5 years (34 to 85) and mean follow-up was 75 months (54 to 125). Twenty-four hips (50%) had a Paprosky IIIA defect, 14 (29.2%) had a type IIIB defect, six (12.5%) had a type IIC defect, and four hips (8.3%) had a type IIB defect. None of the patients had pelvic discontinuity (PD). Results At a mean 6.25 years follow-up, all hips remained well-fixed and implant survival of 100% with the need of re-revision as the end point. Screw fixation was used for all shells; augments and the shell-augment interface was cemented. Excellent pain relief (mean WOMAC score pain 90.5, (38.3 to 100)), and functional outcomes (mean WOMAC function 88.3 (31.9 to 100), mean OHS 89.2 (31.8 to 100)) were noted. Patient satisfaction scores were excellent. Conclusion This study demonstrated satisfactory mid-term clinical and radiological outcomes of using TM shell and augment for reconstructing major acetabular defects without PD in revision THA.
引用
收藏
页码:1515 / 1520
页数:6
相关论文
共 50 条
  • [31] Unexpected positive cultures in aseptic revision hip and knee arthroplasty: prevalence and outcomes at mid-term follow-up
    Kayani, B.
    Mancino, F.
    Baawa-Ameyaw, J.
    Roussot, M. A.
    Haddad, F. S.
    BONE & JOINT OPEN, 2024, 5 (10): : 832 - 836
  • [32] Hip Arthroplasty With the Use of a Reconstruction Cage and Porous Metal Augment to Treat Massive Acetabular Bone Loss: A Midterm Follow-Up
    Garceau, Simon P.
    Warschawski, Yaniv
    Joly, Denis
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S636 - S641
  • [33] Biological downsizing. Acetabular defect reconstruction in revision total hip arthroplasty
    Koob, S.
    Scheidt, S.
    Randau, T. M.
    Gathen, M.
    Wimmer, M. D.
    Wirtz, D. C.
    Gravius, S.
    ORTHOPADE, 2017, 46 (02): : 158 - 167
  • [34] Minimum Five-Year Outcomes with Porous Tantalum Acetabular Cup and Augment Construct in Complex Revision Total Hip Arthroplasty
    Jenkins, Derek R.
    Odland, Andrew N.
    Sierra, Rafael J.
    Hanssen, Arlen D.
    Lewallen, David G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (10): : e49
  • [35] Use of Customized 3D-Printed Titanium Augment With Tantalum Trabecular Cup for Large Acetabular Bone Defects in Revision Total Hip Arthroplasty: A Midterm Follow-Up Study
    Kong, Keyu
    Zhao, Chen
    Chang, Yongyun
    Qiao, Hua
    Hu, Yi
    Li, Huiwu
    Zhang, Jingwei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [36] Outcomes of total hip arthroplasty with a standard prosthesis for the affected hip in patients with poliomyelitis sequelae: a mid-term retrospective follow-up study
    Lihan Shi
    Guangwei Che
    Yong Huang
    Min Yi
    Pengde Kang
    Journal of Orthopaedic Surgery and Research, 18
  • [37] Outcomes of total hip arthroplasty with a standard prosthesis for the affected hip in patients with poliomyelitis sequelae: a mid-term retrospective follow-up study
    Shi, Lihan
    Che, Guangwei
    Huang, Yong
    Yi, Min
    Kang, Pengde
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [38] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Sakai, Takashi
    Ohzono, Kenji
    Nishii, Takashi
    Takao, Masaki
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 605 - 610
  • [39] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Takashi Sakai
    Kenji Ohzono
    Takashi Nishii
    Masaki Takao
    Hidenobu Miki
    Nobuo Nakamura
    Nobuhiko Sugano
    International Orthopaedics, 2013, 37 : 605 - 610
  • [40] Mid- to Long-term Follow-up of Severe Acetabular Bone Defect after Revision Total Hip Arthroplasty Using Impaction Bone Grafting and Metal Mesh
    Yang, Chao
    Zhu, Kechao
    Dai, Huiyong
    Zhang, Xianlong
    Wang, Qiaojie
    Wang, Qi
    ORTHOPAEDIC SURGERY, 2023, 15 (03) : 750 - 757