Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents

被引:4
|
作者
Obmann, Markus M. [1 ,2 ]
Sun, Yuxin [1 ]
An, Chansik [1 ]
Ohliger, Michael A. [1 ]
Wang, Zhen J. [1 ]
Yeh, Benjamin M. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, 505 Parnassus Ave,Box 0628, San Francisco, CA 94143 USA
[2] Univ Hosp Basel, Dept Radiol & Nucl Imaging, Basel, Switzerland
基金
美国国家卫生研究院;
关键词
artifacts; CT; contrast media; image processing; peristalsis; ORAL-CONTRAST; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; MOTION ARTIFACT; IODINE; PRINCIPLES; MEDIA;
D O I
10.2214/AJR.21.26345
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. The value of dual-energy CT (DECT) for bowel wall assessment is increasingly recognized. Although technical improvements reduce peristalsis artifact in conventional CT, the effects of peristalsis on DECT image reconstructions remain poorly studied. OBJECTIVE. The purpose of this study was to evaluate the influence of different DECT scanners and enteric contrast agents on the severity of bowel peristalsis artifact in vitro. METHODS. To simulate bowel peristalsis, a 3-cm-diameter corrugated hollow tube representing the bowel was oscillated constantly in the z-axis within a larger water-filled cylinder. The bowel was serially filled with air, water, and iodinated or experimental dark contrast material and scanned on four different DECT platforms (spectral detector, rapid peak kilovoltage switching, split filter, and dual source) to reconstruct 120-kVp-like and iodine images. Two readers rated each image reconstruction for artifact severity from 0 (none) to 3 (severe) and recorded the degree to which iodine images depicted bowel wall hyperattenuation on 120-kVp-like images as artifactual. Artifact severity scores were compared by ANOVA with Bonferroni correction. RESULTS. Interrater agreement on artifact scores was excellent (intraclass correlation coefficient, 0.82 [95% CI, 0.79-0.84]). For 120-kVp-like images, mean peristalsis artifact scores were lower (all p < .001) for split-filter (1.47) and dual-source (1.86) scanners than for spectral-detector (2.58) and rapid-kilovoltage-switching (2.74) scanners. Compared with those on 120-kVp images, peristalsis artifacts on iodine images were less severe for spectral-detector (score, 1.03; p < .001) and rapid-kilovoltage-switching (2.09; p < .001) systems but more severe for dual-source (2.77; p < .001) and split-filter (2.62; p < .001) systems. Peristalsis artifact was rated less severe with experimental dark bowel contrast medium (score, 1.79) than with other bowel contrast agents (all p <.001). Iodine images helped identify bowel wall hyperattenuation as artifactual in 94.7% of reviewed cases for spectral-detector and 40.7% of cases for rapid-kilovoltage-switching scanners. CONCLUSION. For spectral-detector and rapid-kilovoltage-switching DECT, iodine images minimize peristalsis artifact, but for dual-source and split-filter DECT, mixed 120kVp-like images are preferred. Compared with iodinated contrast material and water, experimental dark bowel contrast material reduces peristalsis artifact. CLINICAL IMPACT. Knowledge of the preferred images for reducing peristalsis artifact can lessen the effect of peristalsis on clinical DECT interpretation. Dark enteric contrast agents, when they become clinically available, may further reduce the effects of peristalsis.
引用
收藏
页码:290 / 299
页数:10
相关论文
共 50 条
  • [21] Dual-Energy CT and Spot Sign
    Vargas, M. I.
    Lovblad, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (10) : E63 - E63
  • [22] Dual-Energy CT and Radiation Dose
    Reher, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2020, 17 (01) : 95 - 96
  • [23] Dual-Energy CT of Intrahepatic Splenosis
    Zhang, Hui-Hui
    Tan, Xian-Zheng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)
  • [24] Renal applications of dual-energy CT
    Kaza, Ravi K.
    Platt, Joel F.
    ABDOMINAL RADIOLOGY, 2016, 41 (06) : 1122 - 1132
  • [25] Dual-Energy CT of Gallstone Ileus
    Liu, Peng
    Tan, Xian-zheng
    RADIOLOGY, 2020, 295 (03) : 516 - 516
  • [26] Dual-Energy CT: Oncologic Applications
    De Cecco, Carlo Nicola
    Darnell, Anna
    Rengo, Marco
    Muscogiuri, Giuseppe
    Bellini, Davide
    Ayuso, Carmen
    Laghi, Andrea
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S98 - S105
  • [27] Clinical Applications of Dual-Energy CT
    Hamid, Saira
    Nasir, Muhammad Umer
    So, Aaron
    Andrews, Gordon
    Nicolaou, Savvas
    Qamar, Sadia Raheez
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 970 - 982
  • [28] Dual-Energy CT Applications in the Abdomen
    Heye, Tobias
    Nelson, Rendon C.
    Ho, Lisa M.
    Marin, Daniele
    Boll, Daniel T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S64 - S70
  • [29] Dual-Energy CT Principles and Applications
    Chellini, David
    Kinman, Karen
    RADIOLOGIC TECHNOLOGY, 2020, 91 (06) : 561CT - 576CT
  • [30] Dual-energy CT in musculoskeletal trauma
    Wong, A. J. N.
    Wong, M.
    Kutschera, P.
    Lau, K. K.
    CLINICAL RADIOLOGY, 2021, 76 (01) : 38 - 49