Dual-mode electrochemiluminescence and electrochemical sensor for alpha-fetoprotein detection in human serum based on vertically ordered mesoporous silica films

被引:30
|
作者
Chen, Haiyun [1 ,2 ]
Huang, Jie [3 ]
Zhang, Rongjing [1 ,2 ]
Yan, Fei [3 ]
机构
[1] Shanxi Med Univ, Hosp 3, Tongji Shanxi Hosp, Shanxi Bethune Hosp,Shanxi Acad Med Sci, Taiyuan, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Wuhan, Peoples R China
[3] Zhejiang Sci Tech Univ, Dept Chem, Key Lab Surface & Interface Sci Polymer Mat Zhejia, Hangzhou, Peoples R China
来源
FRONTIERS IN CHEMISTRY | 2022年 / 10卷
基金
中国国家自然科学基金;
关键词
vertically ordered mesoporous silica film; alpha-fetoprotein; dual-mode detection; electrochemiluminescence; electrochemistry; immunosensor; LABEL-FREE; IMMUNOSENSOR; IMMUNOASSAY; COMPOSITE; ECL;
D O I
10.3389/fchem.2022.1023998
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we demonstrated the highly sensitive detection of alphafetoprotein (AFP) by electrochemiluminescence (ECL) and electrochemistry (EC) based on the gated transport of the bifunctional probe (tris(1,10-phenanthroline) ruthenium (II) chloride, Ru (phen)(3)Cl-2} into the nanochannels of vertically ordered mesoporous silica films (VMSFs). Due to the negatively charged surface and ultrasmall pore size, VMSF displays a signal amplification effect on Ru (phen)(3)Cl-2 and is suitable for the construction of sensors with excellent sensitivity. With the linkage of (3-glycidyloxypropyl) trimethoxysilane, the anti-AFP antibody could covalently bind to the external surface of VMSF, generating a highly specific recognized sensing interface toward AFP. When AFP is presented, the formed immunocomplex hinders the diffusion of Ru (phen)(3)Cl-2 to the underlying electrode surface, resulting in a decreased ECL or EC response. The dual-mode detection of AFP is achieved with a relatively low limit of detection (0.56 fg/ml for ECL and 4.5 pg/ml for EC) and a wide linear range (10 fg/ml similar to 1 mu g/ml for ECL and 10 pg/ml similar to 1 mu g/ml for EC). Moreover, owing to the inherent anti-fouling property of VMSF, satisfactory results in the analysis of human serum were obtained, showing the great potential of the designed strategy in clinical diagnosis.
引用
收藏
页数:11
相关论文
共 48 条
  • [11] Dual-Mode Immunosensor for Electrochemiluminescence Resonance Energy Transfer and Electrochemical Detection of Rabies Virus Glycoprotein Based on Ru(bpy)32+-Loaded Dendritic Mesoporous Silica Nanoparticles
    Li, Jiawen
    Wang, Caiqian
    Wang, Wenjing
    Zhao, Ling
    Han, Heyou
    ANALYTICAL CHEMISTRY, 2022, 94 (21) : 7655 - 7664
  • [12] Dual-mode electrochemical and electrochemiluminescence detection of dopamine based on perylene diimide self-assembly material
    Zhang, Wei
    Zhang, Hong
    Li, Chuan
    Shang, Lei
    Ma, Rongna
    Jia, Liping
    Li, Xiaojian
    Li, Bo
    Wang, Huaisheng
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [13] A novel microchip electrophoresis-based chemiluminescence immunoassay for the detection of alpha-fetoprotein in human serum
    Liu, Jingwen
    Zhao, Jingjin
    Li, Shuting
    Zhang, Liangliang
    Huang, Yong
    Zhao, Shulin
    TALANTA, 2017, 165 : 107 - 111
  • [14] Construction of Boronate-Affinity Magnetic Immunity SERS Sensor and Detection of Alpha-Fetoprotein (AFP) in Human Serum
    He, Yuhan
    Li, Lijun
    Li, Xiaoxuan
    Lin, Chubing
    Zhang, Yan
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2021, 94 (03) : 860 - 868
  • [15] Ultrasensitive Electrochemical Biosensor Based on Efficient PDA-APDMAO Antifouling Interface and Dual-Signal Ratio Strategy for Trace Detection of Alpha-Fetoprotein in Human Serum
    Ding, Yan
    Zhang, Minghao
    Ding, Mengli
    Ji, Xiaoting
    Song, Xianzhen
    Ding, Caifeng
    ANALYTICAL CHEMISTRY, 2024, 96 (35) : 14108 - 14115
  • [16] Highly sensitive detection of rutin in pharmaceuticals and human serum using ITO electrodes modified with vertically-ordered mesoporous silica-graphene nanocomposite films
    Ma, Xinyu
    Liao, Wenyan
    Zhou, Huaxu
    Tong, Yun
    Yan, Fei
    Tang, Hongliang
    Liu, Jiyang
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (46) : 10630 - 10636
  • [17] Dual-mode detection and efficient annihilation of pathogenic bacteria based on the construction of a ratiometric electrochemiluminescent/electrochemical sensor
    Shan, Xia
    Feng, Qiumei
    Yang, Jie
    Wang, Po
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 372
  • [18] Vertically-ordered mesoporous silica films on graphene for anti-fouling electrochemical detection of tert-butylhydroquinone in cosmetics and edible oils
    Yan, Fei
    Wang, Meifang
    Jin, Qifan
    Zhou, Huaxu
    Xie, Liuhong
    Tang, Hongliang
    Liu, Jiyang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 881
  • [19] Dual-Mode Wearable Strain Sensor Based on Graphene/Colloidal Crystal Films for Simultaneously Detection of Subtle and Large Human Motions
    Xu, Hua
    Zhang, Ming Kun
    Lu, Yi Fei
    Li, Jia Jia
    Ge, Si Jia
    Gu, Zhong Ze
    ADVANCED MATERIALS TECHNOLOGIES, 2020, 5 (02)
  • [20] An electrochemical biosensor for alpha-fetoprotein detection in human serum based on peptides containing isomer D-Amino acids with enhanced stability and antifouling property
    Zhao, Shuju
    Liu, Nianzu
    Wang, Wenqi
    Xu, Zhenying
    Wu, Yumin
    Luo, Xiliang
    BIOSENSORS & BIOELECTRONICS, 2021, 190