A complete simulation of x-ray angiography

被引:2
|
作者
Hall, P [1 ]
机构
[1] Cardiff Univ Wales, Dept Comp Sci, Cardiff CF2 3XF, S Glam, Wales
关键词
angiography; vascular modelling; x-ray images; animation; visualisation;
D O I
10.1117/12.310832
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a complete simulation of x-ray angiography, which we have used as tool to assist our research work in three-dimensional reconstruction of vasculature from x-ray angiograms.)X-ray angiography is an image acquisition technique routinely used in clinical practice to obtain images of blood vessel networks, which operates as follows: x-ray opaque dye is injected into the blood flow and is driven through the vessel network by time varying pressure gradients. An x-ray device captures a sequence of images as the dye flows, yielding an animation in which each image shows part of the vasculature. Once an animation from a given point of view has been acquired, the x-ray device is moved to a new position and the whole process is repeated. The final result is a set of animations. The simulation is able to reproduce all the salient points of x-ray angiography. Given our motivation (reconstructing vascular skeletons) are generalised the simulation so that it can produce static images of complete vasculature, and pre-segmented images that represent key stages in our reconstruction algorithm.
引用
收藏
页码:1064 / 1075
页数:12
相关论文
共 50 条
  • [1] Stereoscopic x-ray angiography
    Talukdar, AS
    Wilson, DL
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 795 - 798
  • [2] Effect of X-ray system motion blur in X-ray angiography
    Xue, P
    Wilson, DL
    RADIOLOGY, 1996, 201 : 503 - 503
  • [3] Simulation of a complete X-ray digital radiographic system for industrial applications
    Nazemi, E.
    Rokrok, B.
    Movafeghi, A.
    Dastjerdi, M. H. Choopan
    APPLIED RADIATION AND ISOTOPES, 2018, 139 : 294 - 303
  • [4] On the ultimate x-ray detector for angiography
    Slump, CH
    Kauffman, JA
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 729 - 736
  • [5] Rotational x-ray coronary angiography
    Raman, SV
    Morford, R
    Neff, M
    Attar, TT
    Kukielka, G
    Magorien, RD
    Bush, CA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (02) : 201 - 207
  • [6] A new X-ray apparatus with complete X-ray and electrical protection
    Bouwers, A
    ACTA RADIOLOGICA, 1928, 9 (06) : 600 - 605
  • [7] X-Ray Calc: A software for the simulation of X-ray reflectivity
    Penkov, Oleksiy, V
    Kopylets, Igor A.
    Khadem, Mahdi
    Qin, Tianzuo
    SOFTWAREX, 2020, 12
  • [8] X-ray variability in a complete sample of soft X-ray selected AGN
    Grupe, D
    Thomas, HC
    Beuermann, K
    ASTRONOMY & ASTROPHYSICS, 2001, 367 (02) : 470 - 486
  • [9] X-RAY CRYSTALLOGRAPHY OF A COMPLETE IMMUNOGLOBULIN
    SARMA, VR
    DAVIES, DR
    ACTA CRYSTALLOGRAPHICA SECTION A-CRYSTAL PHYSICS DIFFRACTION THEORETICAL AND GENERAL CRYSTALLOGRAPHY, 1969, A 25 : S187 - &
  • [10] SIMULATION OF X-RAY TOPOGRAPHS
    EPELBOIN, Y
    MATERIALS SCIENCE AND ENGINEERING, 1985, 73 (1-2): : 1 - 43