Reconstruction of elastic modulus distribution from envelope detected B-mode data

被引:0
|
作者
Doyley, MM
Bamber, JC
Shiina, T
Leach, MO
机构
来源
1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2 | 1996年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A variety of ultrasonic methods have been shown to be capable of imaging the stiffness of soft tissue but most require specialised equipment and non-standard approaches to ultrasonic examination. In breast imaging by Elastography, for example, the elastic modulus distribution (EMD) is estimated by using 1-D cross correlation tracking of radiofrequency (RF) echo signals to image the distribution of strain induced by a controlled static deformation: Our work aims to explore the possibilities for employing standard ultrasound scanning methods and equipment, and simple processing techniques, to image the EMD of soft tissues. A simple reconstruction algorithm was developed and its convergence was studied at different elastic contrasts (EC) using 'ideal' strain data that was derived using the finite element method. EMD reconstruction of hard inclusions improved substantially according to a Chi-squared statistic, but soft inclusions showed little change after the first iteration. For example Chi-squared for a + 20 dB EC inclusion reduced from 10 at the start to 0.0001 after 5 iterations, whilst it improved from 3 to only 1.6 for a - 20 dB inclusion. The performance of a 1-D cross correlation tracking algorithm was studied with RF and envelope detected data when external strains of 2% and 5% were applied to the surface of a simulated phantom. The algorithm accurately estimated displacement less than or equal to 1.5 lambda with both RF and ED data when the applied strain was 2%. However better precision and signal to noise ratio (SNR) was obtained using RF as oppose to ED. At an applied strain of 5% more accurate estimates, better precision and SNR was obtain using ED. We conclude that there is no great disadvantage to using the envelope detected signal for estimating internal tissue displacements that are likely to be encountered in standard clinical scanning practice.
引用
收藏
页码:1611 / 1614
页数:4
相关论文
共 50 条
  • [21] Detection of B-Mode Polarization in the Cosmic Microwave Background with Data from the South Pole Telescope
    Hanson, D.
    Hoover, S.
    Crites, A.
    Ade, P. A. R.
    Aird, K. A.
    Austermann, J. E.
    Beall, J. A.
    Bender, A. N.
    Benson, B. A.
    Bleem, L. E.
    Bock, J. J.
    Carlstrom, J. E.
    Chang, C. L.
    Chiang, H. C.
    Cho, H-M.
    Conley, A.
    Crawford, T. M.
    de Haan, T.
    Dobbs, M. A.
    Everett, W.
    Gallicchio, J.
    Gao, J.
    George, E. M.
    Halverson, N. W.
    Harrington, N.
    Henning, J. W.
    Hilton, G. C.
    Holder, G. P.
    Holzapfel, W. L.
    Hrubes, J. D.
    Huang, N.
    Hubmayr, J.
    Irwin, K. D.
    Keisler, R.
    Knox, L.
    Lee, A. T.
    Leitch, E.
    Li, D.
    Liang, C.
    Luong-Van, D.
    Marsden, G.
    McMahon, J. J.
    Mehl, J.
    Meyer, S. S.
    Mocanu, L.
    Montroy, T. E.
    Natoli, T.
    Nibarger, J. P.
    Novosad, V.
    Padin, S.
    PHYSICAL REVIEW LETTERS, 2013, 111 (14)
  • [22] Segmentation of B-mode cardiac ultrasound data by Bayesian Probability Maps
    Hansson, Mattias
    Brandt, Sami S.
    Lindstrom, Johan
    Gudmundsson, Petri
    Jujic, Amra
    Malmgren, Andreas
    Cheng, Yuanji
    MEDICAL IMAGE ANALYSIS, 2014, 18 (07) : 1184 - 1199
  • [23] Applicability of ARFI elastography in the evaluation of canine prostatic alterations detected by b-mode and Doppler Ultrasonography
    Cintra, C. A.
    Feliciano, M. A. R.
    Santos, V. J. C.
    Maronezi, M. C.
    Cruz, I. K.
    Gasser, B.
    Silva, P.
    Crivellenti, L. Z.
    Uscategui, R. A. R.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2020, 72 (06) : 2135 - 2140
  • [24] ACOUSTIC SHADOW DETECTION: STUDY AND STATISTICS OF B-MODE AND RADIOFREQUENCY DATA
    Hu, Ricky
    Singla, Rohit
    Deeba, Farah
    Rohling, Robert N.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (08): : 2248 - 2257
  • [25] CAROTID LESIONS DETECTED BY B-MODE ULTRASONOGRAPHY IN TAKAYASU ARTERITIS - MACARONI SIGN AS AN INDICATOR OF THE DISEASE
    MAEDA, H
    HANDA, N
    MATSUMOTO, M
    HOUGAKU, H
    OGAWA, S
    OKU, N
    ITOH, T
    MORIWAKI, H
    YONEDA, S
    KIMURA, K
    KAMADA, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07): : 695 - 701
  • [26] CORRELATION OF CAROTID BRUITS AND CAROTID ATHEROSCLEROSIS DETECTED BY B-MODE REAL-TIME ULTRASONOGRAPHY
    WHITE, AD
    CAROLAN, G
    WOODCOCK, JP
    PATHY, MSJ
    STROKE, 1990, 21 (04) : 677 - 677
  • [27] CORRELATION OF CAROTID BRUITS AND CAROTID ATHEROSCLEROSIS DETECTED BY B-MODE REAL-TIME ULTRASONOGRAPHY
    HOWARD, VJ
    HOWARD, G
    HARPOLD, GJ
    NUNN, CL
    MYERS, LG
    MCKINNEY, WM
    MURROS, KE
    TOOLE, JF
    STROKE, 1989, 20 (10) : 1331 - 1335
  • [29] Classification of ultrasonic B-mode images of breast masses using Nakagami distribution
    Shankar, PM
    Dumane, VA
    Reid, JM
    Genis, V
    Forsberg, F
    Piccoli, CW
    Goldberg, BB
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (02) : 569 - 580