Design and analysation of DC voltage synchronisation control for a VSC-MTDC based on virtual synchronous generator

被引:10
|
作者
Cao, Xin [1 ]
Han, Minxiao [1 ]
Khan, Zmarrak Wali [1 ]
Zhang, Lidong [2 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing 102206, Peoples R China
[2] ABB Corp Res, S-72178 Sweden, Sweden
关键词
HVDC power transmission; phase locked loops; synchronisation; power system stability; HVDC power convertors; voltage control; synchronous generators; transfer functions; damping; power grids; invertors; power transmission control; closed loop systems; voltage-source convertors; ac systems; VSC-HVDC; weak ac system; phase-locked loop synchronisation; PLL synchronisation; dc voltage synchronisation control; DCSC; power synchronisation control; power balance equation; virtual synchronous generator; voltage sensitivity indicator; voltage fluctuations; closed-loop transfer function; virtual damping coefficient; inertia time; strong controllability; inverter; strong ac system; power transfer capability; voltage source converter-based high-voltage dc; fast power reversal; individual control; active power; reactive power; three terminals VSC-MTDC model; HVDC; GRIDS;
D O I
10.1049/iet-gtd.2018.6078
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Voltage source converter (VSC)-based high-voltage dc (HVDC) transmission is widely utilised nowadays. However, a VSC-HVDC connected to a weak ac system still faces the problem of phase-locked loop (PLL) synchronisation. To tackle this problem, this study proposes a dc voltage synchronisation control (DCSC) based on the power synchronisation control and the power balance equation of the virtual synchronous generator. To analyse the dynamic stability of DCSC, voltage sensitivity indicator (VSI) is used to reflect the voltage fluctuations. Considering the deviations of dc voltage and converter losses, a closed-loop transfer function of dc voltage is designed. Three important parameters including VSI, virtual damping coefficient and inertia time constant are investigated. The dynamic stability analysis shows DCSC has strong controllability. Then, a three terminals VSC-MTDC model is simulated in PSCAD/EMTDC. Herein, DCSC is used in one inverter and PLL is used in another inverter. The waveforms obtained by using DCSC are compared with that by using PLL. Simulation results clearly depict that the inverter with DCSC has a normal steady state and a better transient response than using PLL when connected to a strong ac system, also provides better power transfer capability when connected to a weak ac system.
引用
收藏
页码:449 / 459
页数:11
相关论文
共 50 条
  • [31] Distributed collaborative optimization DC voltage control strategy for VSC-MTDC system with renewable energy integration
    LI, Jingye
    Dong, Haiying
    ARCHIVES OF ELECTRICAL ENGINEERING, 2022, 71 (02) : 325 - 342
  • [32] Additional Frequency Adaptive Droop Control Strategy Considering DC Voltage Stability for VSC-MTDC System
    Liu Y.
    Cui H.
    Liang H.
    He J.
    Dianwang Jishu/Power System Technology, 2020, 44 (06): : 2160 - 2168
  • [33] DC voltage deviation-dependent voltage droop control method for VSC-MTDC systems under large disturbances
    Wang, Yizhen
    Li, Bin
    Zhou, Zexin
    Chen, Zhengguang
    Wen, Weijie
    Li, Xialin
    Wang, Chengshan
    IET RENEWABLE POWER GENERATION, 2020, 14 (05) : 891 - 896
  • [34] An Advanced DC Voltage Control for Virtual Synchronous Generator
    Xie, Zhiwen
    Tang, Niang
    Chen, Lu
    Yuan, Chang
    2021 5TH INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2021), 2021, : 47 - 51
  • [35] Analysis and Control of DC Voltage Dynamics Based on a Practical Reduced-Order Model of Droop-Controlled VSC-MTDC System in DC Voltage Control Timescale
    Wang, Yizhen
    Wang, Zhiqian
    Lei, Ming
    Qiu, Fengliang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 1031 - 1039
  • [36] A control strategy based on local signal measuring for VSC-MTDC
    Ding, Tao
    Zhang, Chengxue
    Sun, Yuanbo
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (09): : 44 - 48
  • [37] Analysis of Virtual Damping Supplied From CFC to the DC Oscillation Mode in VSC-MTDC
    Fu Q.
    Du W.
    Wang H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (08): : 2489 - 2500
  • [38] Adaptive Droop Control Strategy for VSC-MTDC System Considering DC Voltage Errors Among Converter Stations
    Liu Y.
    Xie S.
    Liang H.
    Xie Q.
    Liu, Yingpei (liuyingpei_123@126.com), 1600, Chinese Machine Press (35): : 3270 - 3280
  • [39] Cooperative Optimal Droop Control for VSC-MTDC System with Quasi Non-error DC Voltage Regulation
    Liu H.
    Liu C.
    Zheng L.
    Wang Q.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (06): : 117 - 126
  • [40] A distributed DC voltage control method for VSC MTDC systems
    Dierckxsens, C.
    Srivastava, K.
    Reza, M.
    Cole, S.
    Beerten, J.
    Belmans, R.
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 82 (01) : 54 - 58