Optimization of the method of measuring left ventricular end-diastolic diameter in cardiac magnetic resonance as a predictor of left ventricular enlargement

被引:3
|
作者
Gac, Pawel [1 ,2 ]
Waszczuk, Lukasz [1 ]
Kurcz, Jacek [1 ]
Poreba, Rafal [3 ]
机构
[1] Wroclaw Med Univ, Dept Gen & Intervent Radiol & Neuroradiol, Borowska 213, PL-50556 Wroclaw, Poland
[2] Wroclaw Med Univ, Dept Populat Hlth, Div Environm Hlth & Occupat Med, Mikulicza Radeckiego 7, PL-50368 Wroclaw, Poland
[3] Wroclaw Med Univ, Dept Internal Med Occupat Dis & Hypertens, Borowska 213, PL-50556 Wroclaw, Poland
关键词
EJECTION FRACTION; MASS; ECHOCARDIOGRAPHY; QUANTIFICATION; VARIABILITY; VOLUME; SIZE;
D O I
10.1038/s41598-022-12359-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The objective of the study was to optimize the method of measuring left ventricular end-diastolic diameter (LVEDD) in cardiac magnetic resonance (CMR) as a predictor of left ventricular end-diastolic volume (LVEDV). The study group consisted of 78 patients (age 55.28 +/- 17.18) who underwent 1.5 T CMR examination. LVEDD measurements in the short axis, in the long axis in the 2-chamber, 3-chamber and 4-chamber views were made by 2 radiologists. The repeatability of LVEDD measurements was assessed. The sensitivity and specificity of various methods of measuring LVEDD as a predictor of left ventricular enlargement (diagnosed based on LVEDV) were assessed. The correlation coefficients between LVEDD measurements made by researcher A and B were 0.98 for the long axis measurements in the 2-chamber and 3-chamber view, and 0.99 for measurements made in the short axis and in the long axis in the 4-chamber view. The lowest LVEDD measurements variability was recorded for the short axis measurements (RD 0.02, CV 1.38%), and the highest for the long axis measurements in the 3-chamber view (RD 0.04, CV 2.53%). In the male subgroup, the highest accuracy in predicting left ventricular enlargement was characterized by the criterion "LVEDD measured in the long axis in the 2-chamber view > 68.0 mm" (accuracy 94.1%). In the female subgroup, the highest accuracy in predicting left ventricular enlargement was achieved by the criterion "LVEDD measured in the short axis > 63.5 mm" (96.3%). In summary, the measurement made in the short axis should be considered the optimal method to LVEDD measure in CMR, considering the repeatability of measurements and the accuracy of left ventricular enlargement prediction.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A RAPID NONGEOMETRIC ASSESSMENT OF LEFT-VENTRICULAR END-DIASTOLIC VOLUME
    NANNA, M
    BAREKET, Y
    WU, JJ
    PALMA, A
    GOLDBERGER, M
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1995, 12 (04): : 239 - 246
  • [42] Left Ventricular Reverse Remodeling With a Continuous Flow Left Ventricular Assist Device Measured by Left Ventricular End-Diastolic Dimensions and Severity of Mitral Regurgitation
    Morgan, Jeffrey A.
    Brewer, Robert J.
    Nemeh, Hassan W.
    Murthy, Raghav
    Williams, Celeste T.
    Lanfear, David E.
    Tita, Cristina
    Paone, Gaetano
    ASAIO JOURNAL, 2012, 58 (06) : 574 - 577
  • [43] Is there a relationship between resistin levels and left ventricular end-diastolic pressure?
    Yildirim, Ozge Turgay
    Yildirir, Aylin
    Sade, Leyla Elif
    Hasirci, Senem Has
    Kozan, Hatice
    Ozcalik, Emre
    Okyay, Kaan
    Bal, Ugur Abbas
    Aydinalp, Alp
    Muderrisoglu, Haldun
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2018, 19 (04): : 267 - 272
  • [45] Does Lung Ultrasonography Predict Left Ventricular End-Diastolic Pressure?
    Wiesen, J.
    Adams, J.
    Hobbs, R.
    Bott-Silverman, C.
    Koenig, S.
    Tonelli, A. R.
    Moghekar, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [46] LEFT VENTRICULAR END-DIASTOLIC PRESSURE + TRANSVALVULAR GRADIENT IN MITRAL STENOSIS
    LIBANOFF, AJ
    BOITEAU, GM
    AMERICAN JOURNAL OF CARDIOLOGY, 1964, 13 (01): : 116 - &
  • [47] EFFECT OF RADIOPAQUE CONTRAST MATERIAL ON LEFT VENTRICULAR END-DIASTOLIC PRESSURE
    LEVIN, DC
    BALTAXE, HA
    NEW YORK STATE JOURNAL OF MEDICINE, 1972, 72 (21) : 2619 - &
  • [48] Left Ventricular Internal Diastolic Diameter as a Predictor of Outcomes in Ischemic Cardiomyopathy
    Shatzkes, J.
    Salomon, J.
    Zolty, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S274 - S274
  • [49] Echography of left ventricular end-diastolic diameter as a reliable tool for estimating 'dry weight' in hemodialysis patients
    Funao, K.
    Tsuchida, K.
    Matsuyama, M.
    Kyo, M.
    Naganuma, T.
    Takemoto, Y.
    Nakatani, T.
    Yoshimura, R.
    BLOOD PURIFICATION, 2006, 24 (5-6) : 478 - 479
  • [50] Echography of left ventricular end-diastolic diameter as a reliable tool for estimating "dry weight" in hemodialysis patients
    Yoshimura, R
    Goto, T
    Tsuchida, K
    Takemoto, Y
    Wada, S
    Sano, H
    Kishimoto, T
    Yamamoto, K
    Nakatani, T
    RENAL FAILURE, 2003, 25 (01) : 31 - 41