Microfluidic purification and preconcentration of mRNA by flow-through polymeric monolith

被引:43
|
作者
Satterfield, Brent C.
Stern, Seth
Caplan, Michael R.
Hukari, Kyle W.
West, Jay A. A. [1 ]
机构
[1] Arcxis Biotechnol, Pleasanton, CA 94566 USA
[2] Arizona State Univ, Harrington Dept Bioengn, Tempe, AZ 85287 USA
关键词
D O I
10.1021/ac0709201
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Efficient and rapid isolation of mRNA is important in the field of genomics as well as in the clinical and pharmaceutical arena. We have developed UV-initiated methacrylate-based porous polymer monoliths (PPM) for microfluidic trapping and concentration of eukaryotic mRNA. PPM are cast-to-shape and are tunable for functionalization using a variety of amine-terminated molecules. Efficient isolation of eukaryotic mRNA from total RNA was first mathematically modeled and then achieved using PPM in capillaries. Purification protocols using oligo dT's, locked nucleic acid substituted dT's, and tetramethylammonium chloride salts were characterized. mRNA yield and purity were compared with mRNA isolated by commercial kits with statistically equivalent yields and purities (determined by qPCR ratio of .18s rRNA and Gush mRNA markers). Even after extracting 16 mu g of mRNA from 315 mu g of total RNA, the 0.4-mu L volume monolith showed no signs of saturation. Elution volumes were below 20 mu L with concentrations up to 1 mu g/mu L. In addition, the polymeric material exhibited exceptional stability in a range of conditions (pH, temperature, dryness) and was stable for a period of months. All of these characteristics make porous polymer monoliths good candidates for potential microfluidic sample preconcentrators and purifiers.
引用
收藏
页码:6230 / 6235
页数:6
相关论文
共 50 条
  • [41] FLOW-THROUGH ENTHALPIMETRY
    BERGE, H
    LAMMERT, R
    ZEITSCHRIFT FUR CHEMIE, 1987, 27 (09): : 319 - 323
  • [42] Flow-Through Assemblies
    Lstiburek, Joseph W.
    ASHRAE JOURNAL, 2015, 57 (12) : 46 - 51
  • [43] Cyclodextrin cross-linked polymer monolith for efficient removal of environmental pollutants by flow-through method
    Mizuno, Shunsuke
    Asoh, Taka-Aki
    Takashima, Yoshinori
    Harada, Akira
    Uyama, Hiroshi
    POLYMER DEGRADATION AND STABILITY, 2019, 160 : 136 - 141
  • [44] Preconcentration of Hg(II) and total Hg in waters for flame AAS in a flow-through electrochemical cell
    Manová, A
    Beinrohr, E
    Jurica, L
    CHEMICAL PAPERS, 2003, 57 (03) : 197 - 200
  • [45] FLOW-THROUGH A SLOT
    PAPOUTSIPSYCHOUDAKI, S
    SUTTON, P
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 11 (01) : 21 - 33
  • [46] ALTERNATIVES TO FLOW-THROUGH
    PARSONS, RB
    CIM BULLETIN, 1988, 81 (910): : 80 - 82
  • [47] FLOW-THROUGH ELECTROPHORESIS
    KINAWI, A
    HECKER, A
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (07): : 411 - 419
  • [48] A FUTURE FOR FLOW-THROUGH
    PARSONS, RB
    CIM BULLETIN, 1987, 80 (907): : 78 - 80
  • [49] Design principles of current collectors in microfluidic fuel cell with flow-through porous electrodes
    Li, Li
    Fan, Wenguang
    Xuan, Jin
    Leung, Michacl K. H.
    Zheng, Keqing
    She, Yiyi
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 1557 - 1563
  • [50] Flow-through sampling for electrophoresis-based microfluidic chips using hydrodynamic pumping
    Lin, YH
    Lee, GB
    Li, CW
    Huang, GR
    Chen, SH
    JOURNAL OF CHROMATOGRAPHY A, 2001, 937 (1-2) : 115 - 125