A new cleanup method of dioxins in sediment using large volume injection gas chromatography online coupled with liquid chromatography

被引:4
|
作者
Tang, Fengmei [1 ,2 ]
Ni, Yuwen [1 ]
Zhang, Haijun [1 ]
Li, Yun [1 ]
Jin, Jing [1 ]
Wang, Longxing [1 ]
Chen, Jiping [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
Dioxins; Online cleanup; Gas chromatography; Liquid chromatography; Large volume injection; DIBENZO-P-DIOXINS; MAGNETIC-RESONANCE-SPECTROSCOPY; SOLVENT VAPOR EXIT; POLYCHLORINATED DIBENZOFURANS; ENVIRONMENTAL-SAMPLES; MASS SPECTROMETRY; PERFORMANCE; COLUMNS; SYSTEM; PCBS;
D O I
10.1016/j.aca.2012.04.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new cleanup method was developed and validated for the determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in sediment. The sample extract was first treated with sulfuric acid and then cleaned up by a large volume injection gas chromatography online coupled with liquid chromatography (LVI-GC-LC) system. PCDD/Fs in the extract were separated by a GC column (DB-5), selected cut, cool trapped and transferred to a LC column (alumina). The fraction of PCDD/Fs eluted from the alumina column was collected and concentrated for the instrumental analysis. Under the optimized conditions, LVI-GC-LC method achieved the recoveries of 57-102% for 2,3,7,8-substituted PCDD/Fs, which met the requirements of US Environmental Protection Agency (EPA) Method 1613 and were better than those obtained using the conventional multistep column cleanup method. Meanwhile, compared with the conventional method, the limit of detection (LOD) values of 2,3,7,8-substituted PCDD/Fs cleaned up by LVI-GC-LC method were decreased due to the high-efficiency removal of interferents. These results suggested that the LVI-GC-LC cleanup method was a promising alternative to the multistep cleanup procedure for the determination of dioxins in environmental samples. Crown Copyright (C) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [21] MULTIDIMENSIONAL CHROMATOGRAPHY USING ONLINE COUPLED MICROCOLUMN LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY FOR QUANTITATIVE PESTICIDE-RESIDUE ANALYSIS
    CORTES, HJ
    OLBERDING, EL
    WETTERS, JH
    ANALYTICA CHIMICA ACTA, 1990, 236 (01) : 173 - 182
  • [22] A SAMPLE-INJECTION METHOD FOR GAS-LIQUID CHROMATOGRAPHY
    STANFORD, FG
    ANALYST, 1959, 84 (998) : 321 - 322
  • [23] Miniaturised pressurised liquid extraction of polycyclic aromatic hydrocarbons from soil and sediment with subsequent large-volume injection-gas chromatography
    Ramos, L
    Vreuls, JJ
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (02) : 275 - 286
  • [24] ONLINE MULTIDIMENSIONAL CHROMATOGRAPHY USING PACKED CAPILLARY LIQUID-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY
    CORTES, HJ
    PFEIFFER, CD
    RICHTER, BE
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (08): : 469 - 474
  • [25] Picogram determination of estrogens in water using large volume injection gas chromatography–mass spectrometry
    Ruikang Hu
    Lifeng Zhang
    Zhaoguang Yang
    Analytical and Bioanalytical Chemistry, 2008, 390
  • [26] A METHOD FOR AUTOMATED LARGE VOLUME ON-COLUMN INJECTION CAPILLARY GAS-CHROMATOGRAPHY WITH SOLVENT DIVERSION
    MORABITO, PL
    HILLER, JF
    MCCABE, T
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1989, 12 (05): : 347 - 349
  • [27] Standard on-column injection: A fast and simple method for large volume injection in medium-resolution gas chromatography
    Janssen, HG
    Steenbergen, H
    Oomen, J
    Beens, J
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2000, 12 (10) : 523 - 529
  • [28] MULTIDIMENSIONAL CHROMATOGRAPHY USING ONLINE MICROCOLUMN LIQUID-CHROMATOGRAPHY AND PYROLYSIS-GAS CHROMATOGRAPHY FOR POLYMER CHARACTERIZATION
    CORTES, HJ
    JEWETT, GL
    PFEIFFER, CD
    MARTIN, S
    SMITH, C
    ANALYTICAL CHEMISTRY, 1989, 61 (09) : 961 - 965
  • [29] A novel method for the rapid determination of polyethoxylated tallow amine surfactants in water and sediment using large volume injection with high performance liquid chromatography and tandem mass spectrometry
    Ross, Andrew R. S.
    Liao, Xiangjun
    ANALYTICA CHIMICA ACTA, 2015, 889 : 147 - 155
  • [30] Procedures for large-scale metabolic profiling of serum and plasma using gas chromatography and liquid chromatography coupled to mass spectrometry
    Dunn, Warwick B.
    Broadhurst, David
    Begley, Paul
    Zelena, Eva
    Francis-McIntyre, Sue
    Anderson, Nadine
    Brown, Marie
    Knowles, Joshau D.
    Halsall, Antony
    Haselden, John N.
    Nicholls, Andrew W.
    Wilson, Ian D.
    Kell, Douglas B.
    Goodacre, Royston
    NATURE PROTOCOLS, 2011, 6 (07) : 1060 - 1083