Measurement of fine particulate matter nonvolatile and semi-volatile organic material with the Sunset Laboratory Carbon Aerosol Monitor

被引:14
|
作者
Grover, Brett D. [1 ]
Kleinman, Michael [1 ]
Eatough, Norman L. [1 ]
Eatough, Delbert J. [1 ]
Cary, Robert A. [2 ]
Hopke, Philip K. [3 ]
Wilson, William E. [4 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Sunset Lab Inc, Forest Grove, OR USA
[3] Clarkson Univ, Potsdam, NY USA
[4] US EPA, Res Triangle Pk, NC 27711 USA
关键词
D O I
10.3155/1047-3289.58.1.72
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semi-volatile organic material (SVOM) in fine particles is not reliably measured with conventional semicontinuous carbon monitors because SVOM is lost from the collection media during sample collection. We have modified a Sunset Laboratory Carbon Aerosol Monitor to allow for the determination of SVOM. In a conventional Sunset monitor, gas-phase organic compounds are removed in the sampled airstream by a diffusion denuder employing charcoal-impregnated cellulose filter (CIF) surfaces. Subsequently, particles are collected on a quartz filter and the instrument then determines both the organic carbon and elemental carbon fractions of the aerosol using a thermal/optical method. However, some of the SVOM is lost from the filter during collection, and therefore is not determined. Because the interfering gas-phase organic compounds are removed before aerosol collection, the SVOM can be determined by filtering the particles at the instrument inlet and then replacing the quartz filter in the monitor with a charcoal-impregnated glass fiber filter (CIG), which retains the SVOM lost from particles collected on the inlet filter. The resulting collected SVOM is then determined in the analysis step by measurement of the carbonaceous material thermally evolved from the CIG filter. This concept was tested during field studies in February 2003 in Lindon, UT, and in July 2003 in Rubidoux, CA. The results obtained were validated by comparison with Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS) results. The sum of nonvolatile organic material determined with a conventional Sunset monitor and SVOM determined with the modified Sunset monitor agree with the PC-BOSS results. Linear regression analysis of total carbon concentrations determined by the PC-BOSS and the Sunset resulted in a zero-intercept slope of 0.99 +/- 0.02 (R-2 = 0.92) and a precision of sigma = +/- 1.5 mu g C/m(3) (8%).
引用
收藏
页码:72 / 77
页数:6
相关论文
共 20 条
  • [11] Aerosol Measurement: The Use of Optical Light Scattering for the Determination of Particulate Size Distribution, and Particulate Mass, Including the Semi-Volatile Fraction
    Grimm, Hans
    Eatough, Delbert J.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2009, 59 (01) : 101 - 107
  • [12] Target screening analysis of 970 semi-volatile organic compounds adsorbed on atmospheric particulate matter in Hanoi, Vietnam
    Hanh Thi Duong
    Kadokami, Kiwao
    Ha Thu Trinh
    Thang Quang Phan
    Giang Truong Le
    Dung Trung Nguyen
    Thao Thanh Nguyen
    Dien Tran Nguyen
    CHEMOSPHERE, 2019, 219 : 784 - 795
  • [13] Temperature effect of tapered element oscillating microbalance (TEOM) system measuring semi-volatile organic particulate matter
    Tortajada-Genaro, Luis-Antonio
    Borras, Esther
    JOURNAL OF ENVIRONMENTAL MONITORING, 2011, 13 (04): : 1017 - 1026
  • [14] Qualitative and semi-quantitative analysis of semi-volatile organics from ambient air fine-particulate matter, PM2.5.
    Anderson, RR
    Martello, DV
    Strazisar, BM
    White, CM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U472 - U472
  • [15] Influences of Organic Volatile Compounds on the Secondary Organic Carbon of Fine Particulate Matter in the Fruit Tree Area
    Song, Myoungki
    Kim, Minwook
    Oh, Sea-Ho
    Park, Chaehyeong
    Kim, Moonsu
    Kim, Minsung
    Lee, Hyunji
    Choe, Seoyeong
    Bae, Min-Suk
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [16] Analysis of semi-volatile organic compounds in indoor suspended particulate matter by thermal desorption coupled with gas chromatography/mass spectrometry
    Mercier, Fabien
    Glorennec, Philippe
    Blanchard, Olivier
    Le Bot, Barbara
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1254 : 107 - 114
  • [17] A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth - Part 1: Specifications and testing
    Wendt, Eric A.
    Quinn, Casey W.
    Miller-Lionberg, Daniel D.
    Tryner, Jessica
    L'Orange, Christian
    Ford, Bonne
    Yalin, Azer P.
    Pierce, Jeffrey R.
    Jathar, Shantanu
    Volckens, John
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (10) : 5431 - 5441
  • [18] A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth - Part 3: Automation and design improvements
    Wendt, Eric A.
    Quinn, Casey
    L'Orange, Christian
    Miller-Lionberg, Daniel D.
    Ford, Bonne
    Pierce, Jeffrey R.
    Mehaffy, John
    Cheeseman, Michael
    Jathar, Shantanu H.
    Hagan, David H.
    Rosen, Zoey
    Long, Marilee
    Volckens, John
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (09) : 6023 - 6038
  • [19] Indoor Carbon Dioxide, Fine Particulate Matter and Total Volatile Organic Compounds in Private Healthcare and Elderly Care Facilities
    Baudet, Alexandre
    Baures, Estelle
    Blanchard, Olivier
    Le Cann, Pierre
    Gangneux, Jean-Pierre
    Florentin, Arnaud
    TOXICS, 2022, 10 (03)
  • [20] A low-cost monitor for measurement of fine particulate matter and aerosol optical depth - Part 2: Citizen-science pilot campaign in northern Colorado
    Ford, Bonne
    Pierce, Jeffrey R.
    Wendt, Eric
    Long, Marilee
    Jathar, Shantanu
    Mehaffy, John
    Tryner, Jessica
    Quinn, Casey
    van Zyl, Lizette
    L'Orange, Christian
    Miller-Lionberg, Daniel
    Volckens, John
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (12) : 6385 - 6399