First 500 Fractions Delivered with a Magnetic Resonance-guided Radiotherapy System: Initial Experience

被引:34
|
作者
Sahin, Bilgehan [1 ]
Mustafayev, Teuta Zoto [2 ]
Gungor, Gorkem [1 ]
Aydin, Gokhan [1 ]
Yapici, Bulent [1 ]
Atalar, Banu [2 ]
Ozyar, Enis [3 ]
机构
[1] Acibadem Maslak Hosp, Radiat Oncol, Istanbul, Turkey
[2] Acibadem Univ, Sch Med, Radiat Oncol, Istanbul, Turkey
[3] Acibadem Univ, Sch Med, Acibadem Maslak Hosp, Radiat Oncol, Istanbul, Turkey
关键词
magnetic resonance guided radiotherapy; mr-linac; online adaptive radiotherapy; cine mri; magnetic resonance-guided radiation therapy (mrgrt); sbrt; COMPUTED-TOMOGRAPHY;
D O I
10.7759/cureus.6457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Improved soft-tissue visualization, afforded by magnetic resonance imaging integrated into a radiation therapy linear accelerator-based radiation delivery system (MR-linac) promises improved image-guidance. The availability of MR-imaging can facilitate on-table adaptive radiation planning and enable real-time intra-fraction imaging with beam gating without additional exposure to radiation. However, the novel use of magnetic resonance-guided radiation therapy (MRgRT) in the field of radiation oncology also potentially poses challenges for routine clinical implementation. Herein the early experience of a single institution, implementing the first MRgRT system in the country is reported. We aim to describe the workflow and to characterize the clinical utility and feasibility of routine use of an MR-linac system. Methods The ViewRay MRIdian MR-linac system consists of a split-magnet 0.35 T MR-imaging scanner with a double focused multi-leaf collimator (MLC) equipped 6MV linear accelerator. Unique to the system are the control console integrated on-table adaptive radiation therapy (oART) planning capabilities as well as automated beam gating based on real-time intra-fraction MR imaging. From the first day of clinical implementation, oART was performed according to physicians' discretion when medically indicated. All fractions were delivered under real-time imaging with soft tissue-based automated beam gating with individualized gating boundary settings. Patients actively assisted in breath-hold beam gating with the help of custom designed prismatic glasses allowing sight of a computer monitor mounted on the back wall just behind the MRI system bore. Patient demographics and treatment experience, indications for MRgRT including diagnosis and disease site, radiation dose prescribed and fractionation scheme, utilization of oART, respiratory gating settings, as well as duration of each treatment phase were analyzed. Results Between September 2018 and May 2019, 72 patients with 84 tumor sites were treated with MRgRT in 500 total fractions. Median patient age was 66 years (range: 28-83 years). Among 84 tumor sites, the most frequently treated regions were upper abdominal and pelvic (n = 36, 43% and n = 29, 34%, respectively). The most common diagnosis was prostate cancer, with 14 patients treated. In 69 patients (93.2%) oART was used at least once during a treatment course. Twenty-nine targets (43.1%) with significant breathing-related motion were treated in breath-hold with patient visual feedback. Median prescribed dose was 36.25 Gy (range: 24-70 Gy) in median five fractions (range: 3-28 fractions). A gating boundary of 3 mm around a gating region of interest (gROI) was most commonly used (range: 3-5 mm) with 95% of the gROI (range: 93-97%) required to be within the gating boundary for the beam to automatically engage. Mean total treatment time was 47 min (range: 21-125 min) and mean beam-on time was 16.7 min (range: 6-62 min). Conclusions MRgRT afforded by an MR-linac system has been successfully implemented into routine clinical use at our institution as the first system of its kind in Turkey. While the overall number of patients treated and fractions delivered is still limited, we have demonstrated the feasibility of both on-table adaptive radiation therapy as well as automated real-time beam gating on a daily basis in acceptable time schedules.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Magnetic resonance-guided radiotherapy feasibility in elderly cancer patients: proposal of the MASTER scoring system
    Boldrini, Luca
    Colloca, Giuseppe F.
    Villani, Emanuele
    Chiloiro, Giuditta
    Bellieni, Andrea
    Manfrida, Stefania
    Cellini, Francesco
    Gambacorta, Maria Antonietta
    Valentini, Vincenzo
    TUMORI JOURNAL, 2021, 107 (01): : 26 - 31
  • [22] Feasibility of magnetic resonance-guided adaptive post-prostatectomy radiotherapy
    Hassan, S.
    Jameson, M.
    Batumalai, V.
    Crawford, D.
    Moutrie, Z.
    Hogan, L.
    Loo, C.
    Picton, M.
    Pagulayan, C.
    Jelen, U.
    Alvares, S.
    Heinke, M.
    Sampaio, S.
    Simon, K.
    Twentyman, T.
    Dwivedi, N.
    de Leon, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1166 - S1167
  • [23] Initial Experience with Magnetic Resonance-Guided Vacuum-Assisted Biopsy in Korean Women with Breast Cancer
    Jung, Hye Na
    Han, Boo-Kyung
    Ko, Eun Young
    Shin, Jung Hee
    JOURNAL OF BREAST CANCER, 2014, 17 (03) : 270 - 278
  • [24] Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance-guided radiotherapy system
    Nakayama, Hiroki
    Okamoto, Hiroyuki
    Nakamura, Satoshi
    Iijima, Kotaro
    Chiba, Takahito
    Takemori, Mihiro
    Nakaichi, Tetsu
    Mikasa, Shohei
    Fujii, Kyohei
    Sakasai, Tatsuya
    Kuwahara, Junichi
    Miura, Yuki
    Fujiyama, Daisuke
    Tsunoda, Yuki
    Hanzawa, Takuma
    Igaki, Hiroshi
    Chang, Weishan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [25] Magnetic Resonance-Guided Stereotactic Body Radiotherapy for Metastatic Renal Cell Carcinoma
    Mehanna, E.
    Van Dams, R.
    Mamon, H. J.
    Mancias, J. D.
    Lam, M.
    Tanguturi, S.
    Huynh, M. A.
    Venkatachalam, V.
    Fitzgerald, K. J.
    Mak, R. H.
    Martin, N. E.
    Han, Z.
    Chang, S. L.
    McGregor, B.
    Choueiri, T. K.
    Leeman, J. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E560 - E561
  • [26] Delivery of magnetic resonance-guided single-fraction stereotactic lung radiotherapy
    Finazzi, Tobias
    de Koste, John R. van Sornsen
    Palacios, Miguel A.
    Spoelstra, Femke O. B.
    Slotman, Berend J.
    Haasbeek, Cornelis J. A.
    Senan, Suresh
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 : 17 - 23
  • [27] Magnetic Resonance-guided Radiotherapy - Can We Justify More Expensive Technology?
    Tree, A. C.
    Huddart, R.
    Choudhury, A.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 677 - 679
  • [28] Feasibility of magnetic resonance-guided stereotactic ablative body radiotherapy of liver cancer
    Picton, M.
    Batumalai, V.
    Crawford, D.
    Pagulayan, C.
    Hogan, L.
    Jelen, U.
    Loo, C.
    Dunkerley, N.
    Geddes, L.
    Sampaio, S.
    Heinke, M.
    Twentyman, T.
    Jameson, M.
    de Leon, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S298 - S299
  • [29] Initial experience with magnetic resonance-guided focused ultrasound stereotactic surgery for central brain lesions in young adults
    Tierney, Travis S.
    Alavian, Kambiz N.
    Altman, Nolan
    Bhatia, Sanjiv
    Duchowny, Michael
    Hyslop, Ann
    Jayakar, Prasanna
    Resnick, Trevor
    Wang, Shelly
    Miller, Ian
    Ragheb, John
    JOURNAL OF NEUROSURGERY, 2022, 137 (03) : 760 - 767
  • [30] Accelerating 4D image reconstruction for magnetic resonance-guided radiotherapy
    Lecoeur, Bastien
    Barbone, Marco
    Gough, Jessica
    Oelfke, Uwe
    Luk, Wayne
    Gaydadjiev, Georgi
    Wetscherek, Andreas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27