A Simple and Sensitive Method for the Detection of Trace Pb(II) and Cd(II) based on Nafion-coated Antimony Film Electrode

被引:17
|
作者
Xu He [1 ]
Yang Ping [1 ]
Zheng Qiaoli [1 ]
Liu Jianshe [1 ]
Jin Litong [2 ]
机构
[1] Donghua Univ, Sch Environm Sci & Engn, Shanghai 201620, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
antimony; voltammetry; heavy metals; chemically modified electrode; ANODIC-STRIPPING VOLTAMMETRY; SCREEN-PRINTED ELECTRODES; BATCH-INJECTION-ANALYSIS; CARBON ELECTRODES; MERCURY; LEAD; CADMIUM; SPECIATION; METALS;
D O I
10.1002/cjoc.201090378
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nafion-coated antimony film electrode (NCAFE) was prepared in situ by simultaneously plated antimony with analytes, and applied to the determination of trace Pb(II) and Cd(II) in non-deaerated solutions by differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters, which influenced the response of the NCAFE to those metals, were thoroughly optimized and discussed. The results indicated that the sensitivity and resistance to surfactants at the NCAFE were remarkably improved with relative to the antimony film electrode (AFE). In the presence of 5 mg.L (1) gelatin, the peak heights at the NCAFE showed 4-fold enhancement for Pb and a 9-fold enhancement for Cd over a bare AFE. Reproducibility of the sensor was satisfactory, and the relative standard deviations were 4.8% for 20 mu g.L (1) Pb and 3.2% for 25 mu g.L (1) Cd (n = 15) with preconcentration time of 180 s. The determination limits (S/N= 3) of this sensor were determined to be 0.15 mu g.L (1) for Pb and 0.30 mu g.L (1) for Cd with accumulation time of 300 s. The NCAFE was successfully applied to determining Pb(II) and Cd(II) in vegetable and water samples with satisfactory results.
引用
收藏
页码:2287 / 2292
页数:6
相关论文
共 50 条
  • [31] Anodic stripping voltammetry determination of Pb(II) and Cd(II) at a bismuth/poly(aniline) film electrode
    Zhu, Wei Wei
    Li, Nian Bing
    Luo, Hong Qun
    ANALYTICAL LETTERS, 2006, 39 (11) : 2273 - 2284
  • [32] Electrochemical Detection of Trace Cadmium and Lead on a MCM41/Nafion/Antimony Film Composite-Modified Electrode
    Yin, Yuan
    Wang, Hui
    Liu, Gang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10259 - 10273
  • [33] Simultaneous and Sensitive Detection of Cd(II) and Pb(II) Using a Novel Bismuth Film/Ordered Mesoporous Carbon-molecular Wire Modified Graphite Carbon Paste Electrode
    Zhao, Guo
    Wang, Hui
    Liu, Gang
    Wang, Zhiqiang
    ELECTROANALYSIS, 2017, 29 (02) : 497 - 505
  • [34] Flower-like imide covalent organic framework as an electrochemical platform catcher for simultaneous sensitive detection of trace Pb(II) and Cd (II)
    Zhang, Ru
    Yu, Junhui
    Chen, Haiou
    Zhou, Yu
    Yang, Xiangjun
    Wang, Shixiong
    Bai, Huiping
    MICROCHEMICAL JOURNAL, 2023, 193
  • [35] Simultaneous Determination of Cd(II) and Pb(II) Based on Bismuth Film/Carboxylic Acid Functionalized Multi-Walled Carbon Nanotubes-β-cyclodextrin-Nafion Nanocomposite Modified Electrode
    Zhao, Guo
    Wang, Hui
    Liu, Gang
    Wang, Zhiqiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (10): : 8109 - 8122
  • [36] Evaluation of Bismuth Modified Carbon Thread Electrode for Simultaneous and Highly Sensitive Cd (II) and Pb (II) Determination
    Saeed, Ayman Ali
    Singh, Baljit
    Abbas, Mohammed Nooredeen
    Dempsey, Eithne
    ELECTROANALYSIS, 2016, 28 (09) : 2205 - 2213
  • [37] New Procedures for Voltammetric Determination of Copper(II) and Mercury(II) Using Antimony Film-Coated Carbon Paste Electrode
    Ashrafi, Amir M.
    Vytras, Karel
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 7 - 10
  • [38] Bismuth Film Electrode in Metal Complexation Studies: Stripping Analysis of the Pb(II)-, Cd(II)-, and Zn(II)-Binding with Phthalate
    Serrano, Nuria
    Martin, Nuria
    Manuel Diaz-Cruz, Jose
    Arino, Cristina
    Esteban, Miquel
    ELECTROANALYSIS, 2009, 21 (3-5) : 431 - 438
  • [39] Effects of Humidity, Temperature and Bismuth Electrodeposition on Electroanalytical Performances of Nafion-coated Printed Electrodes for Cd2+ and Pb2+ Detection
    Colozza, Noemi
    Cacciotti, Ilaria
    Moscone, Danila
    Arduini, Fabiana
    ELECTROANALYSIS, 2020, 32 (02) : 345 - 357
  • [40] A Factorial Design and Simplex Optimization of a Bismuth Film Glassy Carbon Electrode for Cd(II) and Pb(II) Determination
    Finsgar, Matjaz
    Rajh, Barbara
    CHEMOSENSORS, 2023, 11 (02)