Grid refinement in adaptive non-rigid registration

被引:0
|
作者
Park, HJ [1 ]
Meyer, CR [1 ]
机构
[1] Univ Michigan, Sch Med, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Non-rigid mutual information (MI) registration algorithms with many degrees of freedom (DOF) are quite useful, but they come at high computational cost and have convergence issues. As a remedy adaptive non-rigid registration algorithms, where DOF is increased adaptively (i.e. the grid is refined adaptively), have been proposed. There are at least two ways to refine a grid adaptively: one based on changes in the global measure, the other based on a local measure. We compare these two and show that a local measure method can have better sensitivity to deformations than the global measure. The local measure employed is a novel method using local entropies and local MI.
引用
收藏
页码:796 / 803
页数:8
相关论文
共 50 条
  • [21] Similarity measures for non-rigid registration
    Rogelj, P
    Kovacic, S
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 569 - 578
  • [22] Interpolation artefacts in non-rigid registration
    Aljabar, P
    Hajnal, JV
    Boyes, RG
    Rueckert, D
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 247 - 254
  • [23] Brownian warps for non-rigid registration
    Nielsen, Mads
    Johansen, Peter
    Jackson, Andrew D.
    Lautrup, Benny
    Hauberg, Soren
    JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2008, 31 (2-3) : 221 - 231
  • [24] Optimal grid point selection for improved non-rigid medical image registration
    Fookes, C
    Maeder, A
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1187 - 1194
  • [25] Locally Rigid Globally Non-rigid Surface Registration
    Fujiwara, Kent
    Nishino, Ko
    Takamatsu, Jun
    Zheng, Bo
    Ikeuchi, Katsushi
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2011, : 1527 - 1534
  • [26] Rigid and non-rigid medical image registration methods
    Dhawan, Atam P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 200 - 219
  • [27] Constrained non-rigid registration for use in image-guided adaptive radiotherapy
    Greene, W. H.
    Chelikani, S.
    Purushothaman, K.
    Knisely, J. P. S.
    Chen, Z.
    Papademetris, X.
    Staib, L. H.
    Duncan, J. S.
    MEDICAL IMAGE ANALYSIS, 2009, 13 (05) : 809 - 817
  • [28] Non-rigid 3D Shape Registration Using an Adaptive Template
    Dai, Hang
    Pears, Nick
    Smith, William
    COMPUTER VISION - ECCV 2018 WORKSHOPS, PT IV, 2019, 11132 : 48 - 63
  • [29] Adaptive Non-rigid Registration and Structure from Motion from Image Trajectories
    Alessio Del Bue
    International Journal of Computer Vision, 2013, 103 : 226 - 239
  • [30] Non-Rigid Point Set Registration via Adaptive Weighted Objective Function
    Yang, Changcai
    Liu, Yizhang
    Jiang, Xingyu
    Zhang, Zejun
    Wei, Lifang
    Lai, Taotao
    Chen, Riqing
    IEEE ACCESS, 2018, 6 : 75947 - 75960