Diagnosis of acute myocardial infarction in patients with renal insufficiency using high-sensitivity troponin T

被引:16
|
作者
Huang, Hualan [1 ]
Zhu, Shuai [1 ]
Wang, Weiqing [1 ]
Yi, Hong [1 ]
Du, Xiangyang [1 ]
Nie, Xin [1 ]
He, Yong [1 ]
Song, Haolan [1 ]
Miao, Qiang [1 ]
Wang, Lanlan [1 ]
Li, Guixing [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Lab Med, Chengdu 610041, Peoples R China
关键词
acute myocardial infarction (AMI); estimated glomerular filtration rate (eGFR); high-sensitivity cardiac troponin T (hs-cTnT); SERUM CYSTATIN-C; ASSAY; PERFORMANCE; CREATININE;
D O I
10.1515/cclm-2014-0715
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The objective of this study was to examine the diagnostic accuracy of high-sensitivity cardiac troponin T (hs-cTnT) for acute myocardial infarction (AMI) in patients with renal insufficiency, since this population has a high incidence of non-AMI elevations of hs-cTnT. Methods: In this prospective study, we enrolled 2249 consecutive patients presenting with chest pain in the emergency department (ED), of whom 19.5% had an estimated glomerular filtration rate (eGFR)(cys) of < 60 mL.min(-1) (1.73 m(2))(-1). Hs-cTnT levels were measured blindly at presentation. Results: Of the patients, 1108 (49.3%) were diagnosed as having AMI [321 with non-ST segment elevation myocardial infarction (NSTEMI)]. In patients whose final diagnosis was not AMI, there was a low but significant correlation between hs-cTnT and renal function [eGFR(cys), r = -0.43 (-0.48, -0.38), p < 0.001; eGFR(creat), r = -0.33 (-0.38, -0.27), p < 0.001]. The area under the curve of the receiver operating characteristic (AUC) for hs-cTnT to diagnose AMI was 0.93 in patients with eGFR(cys) levels of < 30 mL.min(-1) (1.73 m(2))(-1), and AUCs did not vary significantly according to eGFR categories. On the basis of the ROC curve, the optimal threshold value for hs-cTnT was 143.6 ng.L-1 to diagnose AMI in patients with eGFR cys of < 30 mL.min(-1) (1.73 m(2))(-1), with a sensitivity of 83% and a specificity of 91%; 54.1 ng.L-1 in patients with eGFR(cys) between 30 and 59 mL.min(-1), with a sensitivity of 90% and a specificity of 87%; 30.0 ng.L-1 in patients with eGFR(cys) between 60 and 89 mL.min(-1), with a sensitivity of 89% and a specificity of 85%; and 20.3 ng.L-1 in patients with eGFR(cys) = 90 mL.min(-1) (1.73 m(2))(-1), with a sensitivity of 92% and a specificity of 88%. The same observations were done for the diagnosis of NSTEMI. Conclusions: Using a higher hs-cTnT cut-off value based on eGFR level is necessary for accurate diagnosis of AMI or NSTEMI in patients with renal insufficiency.
引用
收藏
页码:723 / 730
页数:8
相关论文
共 50 条
  • [21] High-sensitivity versus conventional troponin in the emergency department for the diagnosis of acute myocardial infarction
    Yonathan Freund
    Camille Chenevier-Gobeaux
    Pascale Bonnet
    Yann-Erick Claessens
    Jean-Christophe Allo
    Benoit Doumenc
    François Leumani
    Claudine Cosson
    Bruno Riou
    Patrick Ray
    Critical Care, 15
  • [22] Combining glucose and high-sensitivity cardiac troponin in the early diagnosis of acute myocardial infarction
    Ana Yufera-Sanchez
    Pedro Lopez-Ayala
    Thomas Nestelberger
    Karin Wildi
    Jasper Boeddinghaus
    Luca Koechlin
    Maria Rubini Gimenez
    Hüseyin Sakiz
    Paolo Bima
    Oscar Miro
    F. Javier Martín-Sánchez
    Michael Christ
    Dagmar I. Keller
    Danielle M. Gualandro
    Damian Kawecki
    Katharina Rentsch
    Andreas Buser
    Christian Mueller
    Scientific Reports, 13
  • [23] DIAGNOSTIC SENSITIVITY OF HIGH SENSITIVITY TROPONIN T IN PATIENTS WITH ACUTE MYOCARDIAL INFARCTION
    Rajdl, D.
    Hromadka, M.
    Trefil, L.
    Racek, J.
    Pechman, V
    Cech, J.
    Rokyta, R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S333 - S333
  • [24] High-Sensitivity Cardiac Troponin I Assay for Early Diagnosis of Acute Myocardial Infarction
    Boeddinghaus, Jasper
    Nestelberger, Thomas
    Twerenbold, Raphael
    Koechlin, Luca
    Meier, Mario
    Troester, Valentina
    Wussler, Desiree
    Badertscher, Patrick
    Wildi, Karin
    Puelacher, Christian
    de Lavallaz, Jeanne du Fay
    Gimenez, Maria Rubini
    Zimmermann, Tobias
    Hafner, Benjamin
    Potlukova, Eliska
    Miro, Oscar
    Javier Martin-Sanchez, F.
    Keller, Dagmar, I
    Reichlin, Tobias
    Mueller, Christian
    Walter, Joan Elias
    Strebe, No
    Kozhuharov, Nikola
    Freese, Michael
    Fuenzalida, Carolina
    Stelzig, Claudia
    Gualandro, Danielle M.
    Michou, Eleni
    Meissner, Kathrin
    Kulangara, Caroline
    Shrestha, Samyut
    Fahrni, Regor
    Osswald, Stefan
    Lopez, Beatriz
    Rodriguez Adrada, Esther
    Ganovska, Eva
    Lohrmann, Jens
    Kloos, Wanda
    Steude, Jana
    User, Andreas B.
    von Eckardstein, Arnold
    Morawiec, Beata
    Kawecki, Damian
    Nowalany-Kozielska, Ewa
    Muzyk, Piotr
    Geigy, Nicolas
    Rentsch, Katharina
    CLINICAL CHEMISTRY, 2019, 65 (07) : 893 - 904
  • [25] High-sensitivity cardiac troponin T is a predictor of recurrent acute coronary syndrome in patients with acute myocardial infarction
    Sheng, S-C
    Lu, X-M
    Kang, Y.
    Du, Y-P
    Wang, G-X
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (02): : 3819 - 3825
  • [26] High-sensitivity cardiac troponin assays for risk stratification and for the diagnosis of acute myocardial infarction
    Vasikaran, Samuel D.
    Macdonald, Stephen P. J.
    Sikaris, Kenneth A.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 209 - 210
  • [27] Combining glucose and high-sensitivity cardiac troponin in the early diagnosis of acute myocardial infarction
    Yufera-Sanchez, Ana
    Lopez-Ayala, Pedro
    Nestelberger, Thomas
    Wildi, Karin
    Boeddinghaus, Jasper
    Koechlin, Luca
    Rubini Gimenez, Maria
    Sakiz, Hueseyin
    Bima, Paolo
    Miro, Oscar
    Martin-Sanchez, F. Javier
    Christ, Michael
    Keller, Dagmar I.
    Gualandro, Danielle M.
    Kawecki, Damian
    Rentsch, Katharina
    Buser, Andreas
    Mueller, Christian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [28] High-sensitivity versus conventional cardiac troponin I in acute myocardial infarction diagnosis
    Trakas, N.
    Karakou, E.
    Georgakopoulou, V.
    Vylliotou, I.
    Sklapani, P.
    Mermigkis, D.
    Panoutsou, V.
    Tsiafaki, X.
    CLINICA CHIMICA ACTA, 2022, 530 : S82 - S82
  • [29] Is a Single High-Sensitivity Troponin T Assay Accurate for the Detection of Acute Myocardial Infarction?
    Kirschner, Jonathan
    Zahn, Greg
    ANNALS OF EMERGENCY MEDICINE, 2016, 68 (03) : 295 - 297
  • [30] Incremental value of copeptin to high-sensitivity cardiac troponin T alone in the early diagnosis of acute myocardial infarction
    Twerenbold, R.
    Reichlin, T.
    Gimenez, M. Rubini
    Jaeger, C.
    Tanglay, Y.
    Osswald, S.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 885 - 885