Evaluation and application of conducting polymer entrapment on quartz crystal microbalance in flow injection immunoassay

被引:22
|
作者
Liu, YC [1 ]
Wang, CM
Hsiung, KP
Huang, CJ
机构
[1] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
[2] Ind Technol Res Inst, Ctr Biomed Engn, Hsinchu 300, Taiwan
[3] Natl Chung Hsing Univ, Grad Inst Vet Microbiol, Taichung 402, Taiwan
来源
BIOSENSORS & BIOELECTRONICS | 2003年 / 18卷 / 07期
关键词
quartz crystal microbalance; flow-injection-analysis; conducting polymer entrapment; pseudorabies virus; point-of-care testing;
D O I
10.1016/S0956-5663(02)00208-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An immunosensor employing conducting polymer entrapment (CPE) method to immobilize immuno-protein on the quartz crystal microbalance (QCM) for clinical flow-injection-analysis (FIA) purpose was exploited. By comparing the CPE approach and the conventional physical immobilization (PI) method, a frequency shift of the former was 47% higher than that of the latter when measuring at 0.5 mg/ml human serum albumin antibody concentration. This implied that CPE was a feasible approach for developing QCM-FIA process. An immunoassay of anti-pseudorabies virus antibody in mouse sera further exemplified its practical potential in diagnostic implication. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:937 / 942
页数:6
相关论文
共 50 条
  • [1] Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay
    Liu, YC
    Wang, CM
    Hsiung, KP
    ANALYTICAL BIOCHEMISTRY, 2001, 299 (02) : 130 - 135
  • [2] Flow-Injection-Based Miniaturized Quartz Crystal Microbalance
    Liang, Jinxing
    Huang, Jia
    Ding, Sheng
    Ueda, Toshitsugu
    SENSORS AND MATERIALS, 2013, 25 (07) : 519 - 526
  • [3] INVESTIGATIONS ON CONDUCTING POLYMER-FILMS WITH A FAST ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE
    DUSEMUND, C
    SCHWITZGEBEL, G
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1991, 95 (11): : 1543 - 1546
  • [4] Quartz crystal microbalance investigations of conducting polymers
    Arbuckle, GA
    Chisarik, J
    Angelopoulos, M
    ANTEC'97 - PLASTICS SAVING PLANET EARTH, CONFERENCE PROCEEDINGS, VOLS 1 - 3, 1997, : 1459 - 1462
  • [5] Flow injection immunosensing of polycyclic aromatic hydrocarbons with a quartz crystal microbalance
    Liu, M
    Li, QX
    Rechnitz, GA
    ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 29 - 38
  • [6] Immunoassay of interferon gamma by quartz crystal microbalance biosensor
    Pohanka, Miroslav
    TALANTA, 2020, 218
  • [7] Application of the Quartz Crystal Microbalance to Nanomedicine
    Hunter, Alan Christy
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2009, 5 (06) : 669 - 675
  • [8] Application of Electrochemical Quartz Crystal Microbalance
    Wei, Xiaoyan
    Wang, Gang
    Li, Anfeng
    Quan, Yizhou
    Chen, Jinwei
    Wang, Ruilin
    PROGRESS IN CHEMISTRY, 2018, 30 (11) : 1701 - 1721
  • [9] Applications of Quartz Crystal Microbalance in Polymer Studies
    Yuan, Hai-yang
    Ma, Chun-feng
    Liu, Guang-ming
    Zhang, Guang-zhao
    ACTA POLYMERICA SINICA, 2021, 52 (07): : 806 - 821
  • [10] Viscoelastic study of conducting polymers using Quartz Crystal Microbalance
    Samani, Mehrdad Bahrami
    Whitten, Philip
    Spinks, Geoffrey
    Cook, Christopher
    SMART STRUCTURES AND MATERIALS 2006: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD), 2006, 6168